AXIS P1343-E Network Camera
Hardware overview
I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:
•Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output will show as active (shown under System Options > Ports & Devices) if the alarm device is activated.
•Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under System Options > Ports & Devices).
Note
The I/O connector is connected to the housing (fan/heater) on delivery, and will trigger an input port event to indicate a fan or heater error when activated. See Events, on page 35 for information on how to set up an event.
Function | Pin | Notes | Specifications |
|
|
|
|
GND | 1 | Ground |
|
|
|
|
|
3.3 V DC Power | 2 | Can be used to power auxiliary equipment. | Max load = 50 mA |
|
| Note: This pin can only be used as power out. |
|
|
|
|
|
Digital Input | 3 | Connect to GND to activate, or leave floating (unconnected) | 0 to +40 V DC |
|
| to deactivate. |
|
|
|
|
|
Digital Output | 4 | Internal connection to ground when activated, floating | Max load =100 mA |
|
| (unconnected) when deactivated. If used with an inductive | Max voltage = +40 V DC |
|
| load, e.g. a relay, a diode must be connected in parallel with |
|
|
| the load, for protection against voltage transients. |
|
|
|
|
|
| 1 |
3.3 V max 50 mA | 2 |
| 3 |
| 4 |
8