Bosch Appliances LP880, CC880 Fault Analysis Mode, 13.1Standard Isolating, 13.2Code to Isolate

Page 11
Fault Analysis Mode

CC880/LP880, SC8016 Operators Guide 14.0

Fault Analysis Mode

 

 

EN 11

13.1Standard Isolating

Standard isolating allows all operators to isolate zones without knowing a valid user code.

How to Isolate a Zone

1.Press the [*] button twice to enter the isolating mode.

Three beeps are heard and the STAY indicator flashes.

2.Enter the zone number (1 to 16), followed by the [*] button (for example, [1 *] = Zone 1,

[1 6 *] = Zone 16).

Each zone to be isolated has a corresponding zone indicator that flashes. If you selected an incorrect zone to be isolated, enter the incorrect zone number again followed by the [*] button. Repeat Step 2 if more than one zone is to be isolated until all zones to be isolated are selected.

3.Press the [#] button after all selected zones are isolated.

Two beeps are heard and the system returns to the disarmed state.

13.2Code to Isolate

Only those user codes with the Code to Isolate priority level can isolate zones. If any user code has this priority level, the method of standard isolating does not function. Your security company must program the priority level for each code.

How to Isolate a Zone

1.Press the [*] button followed by your user code and the [*] button again to enter the isolating mode (for example, [* 2 5 8 0 *]). Three beeps are heard and the STAY indicator flashes.

2.Enter the zone number (1 to 16), followed by the

[*] button (for example, [1 *] = Zone 1, [1 6 *] = Zone 16).

Each zone to be isolated has a corresponding zone indicator that flashes. If you selected an incorrect zone to be isolated, enter the incorrect zone number again followed by the [*] button. Repeat Step 2 if more than one zone is to be isolated until all zones to be isolated are selected.

3.Press the [#] button after all selected zones are isolated.

Two beeps are heard and the system returns to the disarmed state.

14.0 Fault Analysis Mode

If a fault occurs, the FAULT or MAINS indicators flash and the codepad beeps once every minute.

If the AC mains supply failed, the MAINS indicator flashes until the AC mains supply is restored. Pressing the [#] button once acknowledges the fault and stops the codepad from beeping once every minute.

How to Determine the Type of System Fault

To determine which system fault occurred, enter fault analysis mode.

1.Hold down button [5] until two beeps are heard. The FAULT indicator remains steady and the STAY and AWAY indicators flash in unison. Any zone indicators display the type of fault occurred. See 3.8 for the list of system faults that can occur.

2.To exit fault analysis mode and return to the disarmed state, press the [#] button. The FAULT indicator remains displayed and the codepad stops its once a minute beep.

Table 11:

Fault Indicators

 

 

 

 

Zone

 

Indicator

Fault Description

1

Battery Fail

2

Date and Time

3

Sensor Watch

4

Horn Speaker Fail

5

Telephone Line Fail

6

E2 Fault

7

Zone 16 in Alarm (partitioned systems

 

only)

8

Communication Fail

14.1Fault Descriptions

Battery Fail

A low battery fault registers when the system detects a low capacity back-up battery. The system automatically performs a battery test every 4 hrs. and also every time the system is armed.

Date and Time

The date and time fault registers every time the system is powered down. This type of fault does not cause the FAULT indicator to display on the codepad unless your installer programmed the automatic arming time. See Section 15.0 Date and Time to program the date and time.

Sensor Watch

A sensor watch fault registers because one or more detection devices failed to detect any movement during the disarmed state for the time period programmed by your installer. The fault clears once the zone in question detected movement and resets.

While in fault analysis mode, hold down button [5] until two beeps are heard and the zone that reported the sensor watch fault displays.

Bosch Security Systems 6/04 920036O.OG.162

Image 11
Contents CC880/LP880, SC8016 Solution-16, Solution-16SafecomCC880/LP880, SC8016 Operators Guide Copyright NoticeNotice of Liability New Zealand Telepermit NotesCC880/LP880, SC8016 Operators Guide Table of ContentsFigures CC880/LP880, SC8016 Operators Guide TablesIntroduction Specifications3.0 Codepad Indicators 1.0 IntroductionCodepad Indicators 3.1Zone Indicators3.2AWAY Indicator 3.3STAY Indicator3.8FAULT Indicator 3.5MAINS Indicator3.6Off Indicator/Zone Sealed 3.7On Indicator/Zone In Alarm 4.4Arming in STAY Mode 4.1Forced Arming 4.2Arming in AWAY Mode 4.3Arming in STAY Mode4.5Programming STAY Mode 2 Zones 5.0 Disarming the System6.0 Adding User Codes 7.0Deleting User Codes11.0 Codepad Medical Alarm 8.0 Codepad Duress Alarm9.0 Codepad Panic Alarm 10.0 Codepad Fire Alarm13.1Standard Isolating 14.0 Fault Analysis Mode14.1Fault Descriptions Fault Analysis ModeCC880/LP880, SC8016 Operators Guide 15.0 Date and Time16.0 Turning Output Devices On/Off Date and TimeReset Latching Outputs 17.0 Reset Latching Outputs18.0 Testing 20.0 Day Alarm22.2Operation of Codepads in Partitioning 22.1Master Partitioned Codepad Indicators21.0 Codepad ID and Buzzer Tone 22.0 PartitioningCC880/LP880, SC8016 Operators Guide 23.0 Remote Arming By Telephone22.3Arm/Disarm all Areas at the Same Time 25.2Programming Domestic Telephone Numbers 25.3Disable Domestic Dialling25.0 Domestic Dialling 25.1Acknowledging Domestic CallsDomestic Voice Message 26.0 Domestic Voice Message Reporting27.0 Basic Pager Reporting 27.1Basic Pager Display InformationSystem Fault Basic Pager ReportingZone Normal - Alarm - Zone Bypassed Panic/Duress - Fire Alarm - Medical AlarmEN 28.0 PET Pager ReportingPET Pager Reporting CC880/LP880, SC8016 Operators GuideCC880/LP880, SC8016 Operators Guide 29.0 Glossary of TermsGlossary of Terms EN CC880/LP880, SC8016 Operators GuideGlossary of Terms CC880/LP880, SC8016 Operators Guide 30.0 Installation NotesService Notes Installation NotesEnabled Zone DescriptionInstallation Notes Day AlarmCC880/LP880, SC8016 Operators Guide User Code NamesInstallation Notes Default = 2580 User CodeIsolating Method Entry/Exit TimesArming Options Output DescriptionsCC880/LP880, SC8016 Operators Guide Communication OptionsOther System Information Installation NotesCC880/LP880, SC8016 Operators Guide Index IndexCC880/LP880, SC8016 Operators Guide Index Bosch Security Systems 6/04 920036O.OG.162 CC880/LP880, SC8016 Operators Guide IndexEN Bosch Security Systems 6/04 920036O.OG.162 CC880/LP880, SC8016 Operators Guide IndexEN Bosch Security Systems 6/04 920036O.OG.162 CC880/LP880, SC8016 Operators Guide IndexEN Facsimile +612 4998152460B IssueBosch Security Systems 25 Huntingwood Drive Huntingwood NSW Australia Phone +612