Bosch Appliances CC880, LP880 manual Domestic Dialling, 25.1Acknowledging Domestic Calls

Page 16
Domestic Dialling

CC880/LP880, SC8016 Operators Guide 25.0

Domestic Dialling

 

 

EN 16

25.0 Domestic Dialling

Use domestic dialling to call your mobile phone or a relative/friend in the event your control panel activated an alarm. Up to three different telephone numbers can be programmed for the control panel to call when an alarm occurs. Only your installer can program the system to report in the domestic format. However, the master code holder can change the telephone numbers at any time.

25.1Acknowledging Domestic Calls

When an alarm condition occurs, the system calls the first telephone number programmed. When you answer an incoming call, you hear the system emitting a siren tone followed by a pause and repeat continually for 2 min. (for example, siren tone, pause, siren tone, and pause).

If you do not acknowledge the call from the control panel during a pause between siren tones, the control panel hangs up after 2 min. and calls the next telephone number.

Pressing the [*] button for 1 sec. to 3 sec. during the pause acknowledges the call and no further calls are made for that event. If the call was successfully acknowledged, a tone of decreasing pitch is heard.

Table 14: Domestic Dialling Telephone Digits

Digit Required

Number To Program

0

0

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

*

*1

#

*2

4 sec. pause

*3

Break

*4

25.2Programming Domestic Telephone Numbers

If your system is set up for domestic dialling, this function allows any master code holder to program telephone numbers the control panel calls in an alarm.

How to Program Telephone Numbers

1.Enter your four character master code, followed by [2] and the [#] button (for example,

[2 5 8 0 2 #]).

Three beeps are heard and the STAY and AWAY indicators flash.

If there are telephone numbers already programmed, they are displayed one digit at a time by the codepad indicators.

If there are no telephone numbers programmed, two more beeps are heard after entering this mode. These two beeps are normally heard after the last digit of the last telephone number is displayed.

2.Enter all digits for the first telephone number (for example, [9 6 7 2 1 7 1 7]).

As each digit is entered, the corresponding codepad indicators display.

3.If there is more than one telephone number to be programmed, press [*]. This inserts a break between the first telephone number and the second telephone number. If there is only one telephone number to be programmed, press the [#] button to exit this function.

4.Enter all the digits of the second telephone number (for example, [9 6 7 2 1 0 5 5]). As each digit is entered, the corresponding codepad indicators display.

5.After the last digit of the second telephone number is programmed, press the [#] button to exit this function unless a third telephone number is required. If there is a third telephone number to be programmed, press the [*] button to insert a break between the second telephone number and the third telephone number.

25.3Disable Domestic Dialling

To cancel domestic dialling (for example, you are moving and do not want the system to continue calling your mobile phone), enter the following sequence.

1.Enter your four character master code, followed by [2] and the [#] button (for example,

[2 5 8 0 2 #]).

Two beeps are heard and the STAY and AWAY indicators flash.

2.Press the [*] button followed by the [#] button (for example, [* #]).

The STAY and AWAY indicators are disabled.

Bosch Security Systems 6/04 920036O.OG.162

Image 16
Contents Solution-16, Solution-16Safecom CC880/LP880, SC8016Copyright Notice Notice of LiabilityNew Zealand Telepermit Notes CC880/LP880, SC8016 Operators GuideFigures Table of ContentsCC880/LP880, SC8016 Operators Guide Tables CC880/LP880, SC8016 Operators GuideSpecifications 3.0 Codepad Indicators1.0 Introduction Introduction3.1Zone Indicators 3.2AWAY Indicator3.3STAY Indicator Codepad Indicators3.5MAINS Indicator 3.6Off Indicator/Zone Sealed3.7On Indicator/Zone In Alarm 3.8FAULT Indicator4.1Forced Arming 4.2Arming in AWAY Mode4.3Arming in STAY Mode 4.4Arming in STAY Mode5.0 Disarming the System 6.0 Adding User Codes7.0Deleting User Codes 4.5Programming STAY Mode 2 Zones8.0 Codepad Duress Alarm 9.0 Codepad Panic Alarm10.0 Codepad Fire Alarm 11.0 Codepad Medical Alarm14.0 Fault Analysis Mode 14.1Fault DescriptionsFault Analysis Mode 13.1Standard Isolating15.0 Date and Time 16.0 Turning Output Devices On/OffDate and Time CC880/LP880, SC8016 Operators Guide 17.0 Reset Latching Outputs 18.0 Testing 20.0 Day Alarm Reset Latching Outputs22.1Master Partitioned Codepad Indicators 21.0 Codepad ID and Buzzer Tone22.0 Partitioning 22.2Operation of Codepads in Partitioning22.3Arm/Disarm all Areas at the Same Time 23.0 Remote Arming By TelephoneCC880/LP880, SC8016 Operators Guide 25.3Disable Domestic Dialling 25.0 Domestic Dialling25.1Acknowledging Domestic Calls 25.2Programming Domestic Telephone Numbers26.0 Domestic Voice Message Reporting 27.0 Basic Pager Reporting27.1Basic Pager Display Information Domestic Voice MessageBasic Pager Reporting Zone Normal - Alarm - Zone BypassedPanic/Duress - Fire Alarm - Medical Alarm System Fault28.0 PET Pager Reporting PET Pager ReportingCC880/LP880, SC8016 Operators Guide ENGlossary of Terms 29.0 Glossary of TermsCC880/LP880, SC8016 Operators Guide Glossary of Terms CC880/LP880, SC8016 Operators GuideEN 30.0 Installation Notes Service NotesInstallation Notes CC880/LP880, SC8016 Operators GuideZone Description Installation NotesDay Alarm EnabledUser Code Names Installation NotesDefault = 2580 User Code CC880/LP880, SC8016 Operators GuideEntry/Exit Times Arming OptionsOutput Descriptions Isolating MethodCommunication Options Other System InformationInstallation Notes CC880/LP880, SC8016 Operators GuideIndex CC880/LP880, SC8016 Operators Guide IndexCC880/LP880, SC8016 Operators Guide Index EN CC880/LP880, SC8016 Operators Guide IndexBosch Security Systems 6/04 920036O.OG.162 EN CC880/LP880, SC8016 Operators Guide IndexBosch Security Systems 6/04 920036O.OG.162 EN CC880/LP880, SC8016 Operators Guide IndexBosch Security Systems 6/04 920036O.OG.162 4998152460B Issue Bosch Security Systems 25 Huntingwood DriveHuntingwood NSW Australia Phone +612 Facsimile +612