Codepad Indicators

CC880/LP880, SC8016 Operators Guide 3.0

Codepad Indicators

 

 

EN 6

Figure 3: CP5 Eight Zone LCD Codepad

Figure 4: Sixteen Zone LCD Codepad

The codepad is the communications interface between you and your alarm system. Use the codepad to issue commands. The codepad offers both visual and audible indications that guide you through the general operation.

The codepad incorporates numerous indicators. There are zone indicators that show the condition of each zone and four other indicators for general status. The following pages outline a list of situations and the relevant indicators that are seen.

3.1Zone Indicators

1 2 3 …. The zone indicators (1 to 8) display the

status of the zones. Table 2 lists the various circumstances under which the indicators display (such as, Zone Sealed/Zone Unsealed).

Table 2: Zone Indicator

Zone Indicator

Definition

On

Zone is unsealed

Off

Zone is sealed

Flashing Fast

Zone is in alarm condition

(0.25 sec. on/

 

0.25 sec. off)

 

Flashing Slow

Zone is manually isolated or

(1 sec. on/1 sec. off)

selected to be isolated

3.2AWAY Indicator

 

The AWAY indicator shows the system

 

is armed in AWAY Mode. The AWAY

 

indicator also flashes in unison with the

 

STAY indicator when programming

 

various options throughout the

 

Operator’s Manual.

 

See Section 4.2 Arming in AWAY Mode for

 

information on the different methods of

 

arming the system in AWAY Mode.

 

 

Table 3:

AWAY Indicator

 

 

 

 

AWAY

Definition

Indicator

 

On

System is armed in AWAY Mode.

Off

System is not armed in AWAY Mode.

3.3STAY Indicator

The STAY indicator displays that the system is armed in STAY Mode 1 or STAY Mode 2. The STAY indicator also flashes in unison with the AWAY indicator when programming various options throughout the Operator’s Manual. See Section 4.3 Arming in STAY Mode 1 for different methods of arming in STAY Mode 1. See Section 4.4 Arming in STAY Mode 2 to arm in STAY Mode 2.

Table 4: STAY Indicator

STAY

Definition

Indicator

 

On

System is armed in STAY Mode 1

 

or STAY Mode 2.

Off

System is not armed in STAY

 

Mode 1 or STAY Mode 2.

Flashing twice

Zone isolating mode or setting

a second

STAY Mode 2 zones.

Flashing once

Day alarm status – day alarm

every 3 sec.

turned on.

Bosch Security Systems 6/04 920036O.OG.162

Image 6
Contents Solution-16, Solution-16Safecom CC880/LP880, SC8016New Zealand Telepermit Notes Copyright NoticeNotice of Liability CC880/LP880, SC8016 Operators GuideTable of Contents FiguresCC880/LP880, SC8016 Operators Guide Tables CC880/LP880, SC8016 Operators Guide1.0 Introduction Specifications3.0 Codepad Indicators Introduction3.3STAY Indicator 3.1Zone Indicators3.2AWAY Indicator Codepad Indicators3.7On Indicator/Zone In Alarm 3.5MAINS Indicator3.6Off Indicator/Zone Sealed 3.8FAULT Indicator4.3Arming in STAY Mode 4.1Forced Arming4.2Arming in AWAY Mode 4.4Arming in STAY Mode7.0Deleting User Codes 5.0 Disarming the System6.0 Adding User Codes 4.5Programming STAY Mode 2 Zones10.0 Codepad Fire Alarm 8.0 Codepad Duress Alarm9.0 Codepad Panic Alarm 11.0 Codepad Medical AlarmFault Analysis Mode 14.0 Fault Analysis Mode14.1Fault Descriptions 13.1Standard IsolatingDate and Time 15.0 Date and Time16.0 Turning Output Devices On/Off CC880/LP880, SC8016 Operators Guide20.0 Day Alarm 17.0 Reset Latching Outputs18.0 Testing Reset Latching Outputs22.0 Partitioning 22.1Master Partitioned Codepad Indicators21.0 Codepad ID and Buzzer Tone 22.2Operation of Codepads in Partitioning23.0 Remote Arming By Telephone 22.3Arm/Disarm all Areas at the Same TimeCC880/LP880, SC8016 Operators Guide 25.1Acknowledging Domestic Calls 25.3Disable Domestic Dialling25.0 Domestic Dialling 25.2Programming Domestic Telephone Numbers27.1Basic Pager Display Information 26.0 Domestic Voice Message Reporting27.0 Basic Pager Reporting Domestic Voice MessagePanic/Duress - Fire Alarm - Medical Alarm Basic Pager ReportingZone Normal - Alarm - Zone Bypassed System FaultCC880/LP880, SC8016 Operators Guide 28.0 PET Pager ReportingPET Pager Reporting EN29.0 Glossary of Terms Glossary of TermsCC880/LP880, SC8016 Operators Guide CC880/LP880, SC8016 Operators Guide Glossary of TermsEN Installation Notes 30.0 Installation NotesService Notes CC880/LP880, SC8016 Operators GuideDay Alarm Zone DescriptionInstallation Notes EnabledDefault = 2580 User Code User Code NamesInstallation Notes CC880/LP880, SC8016 Operators GuideOutput Descriptions Entry/Exit TimesArming Options Isolating MethodInstallation Notes Communication OptionsOther System Information CC880/LP880, SC8016 Operators GuideIndex CC880/LP880, SC8016 Operators Guide IndexCC880/LP880, SC8016 Operators Guide Index CC880/LP880, SC8016 Operators Guide Index ENBosch Security Systems 6/04 920036O.OG.162 CC880/LP880, SC8016 Operators Guide Index ENBosch Security Systems 6/04 920036O.OG.162 CC880/LP880, SC8016 Operators Guide Index ENBosch Security Systems 6/04 920036O.OG.162 Huntingwood NSW Australia Phone +612 4998152460B IssueBosch Security Systems 25 Huntingwood Drive Facsimile +612