Domestic Voice Message

CC880/LP880, SC8016 Operators Guide 26.0

Domestic Voice Message

Reporting

 

 

Zone Status

EN 17

26.0 Domestic Voice Message Reporting

The system can be configured by your security company to report to your mobile phone when an alarm occurs and play back a pre-recorded message detailing instructions.

The pre-recorded message (up to a maximum of

16 sec. in length) can be changed as many times as necessary. You need to discuss the recording of your message with your security company. To change or program new telephone numbers, see Section 25.2 Programming Domestic Telephone Numbers.

26.1Acknowledging Domestic Voice Message Reporting

When an alarm registers at the control panel, the control panel starts dialling the first telephone number. The recorded voice message starts playback as soon as the control panel dials the first telephone number and repeats itself continuously for 90 seconds.

When you answer the incoming call from the control panel, wait for the recorded message to end. A series of short tones follow the recorded message followed by a 20 sec. pause before the control panel hangs up and dials the next telephone number.

During the 20 sec. pause, press the [*] button on your touch-tone telephone. Alternatively, you can use an optional phone controller (tone generator) if you do not have a touch-tone telephone.

If an optional DTMF Command Module is installed by your security company, you can acknowledge the call during the message playback by pressing the [#] key. You no longer need to wait for the pre-recorded message to end.

27.0 Basic Pager Reporting

This feature is only applicable if your system is reporting to a pocket pager. Basic pager reporting requires some interpretation of the numbers that appear on the display. It is possible to differentiate between 1000 different systems when a number of control panels are reporting to the one pocket pager.

27.1Basic Pager Display Information

The zone status display shows you the status of each zone (1 to 8). Table 15 describes what each number means when displayed on the zone status display.

Table 15: Zone Status Display Descriptions

Number

Zone

Displayed

Description

0

Zone Normal

 

Indicates the corresponding zone is in the

 

sealed state.

1

Alarm

 

Indicates the corresponding zone is unsealed

 

and in alarm condition.

2

Zone Bypassed

 

Indicates a system operator manually isolated

 

the corresponding zone. See Section 13.0

 

Isolating Zones for information on how to

 

manually isolate a zone(s) prior to arming the

 

system.

3

Zone Trouble

 

Indicates a zone was left unsealed after the

 

end of exit time.

System Status

The system status information is divided into four digits.

Table 16: System Status

System Status

Description

Display

 

 

First digit

Indicates whether the system is armed

 

or disarmed:

 

8

= Disarmed

 

9

= Armed

Second digit

Indicates which codepad alarm was

 

triggered by the operator:

 

0

= No Codepad Alarm

 

1

= Codepad Panic or Duress Alarm

 

2

= Codepad Fire Alarm

 

3

= Codepad Medical Alarm

Third digit

Indicates when the AC mains supply has

 

failed:

 

0

= AC Supply is normal

 

1

= AC Supply has failed

Fourth digit

Indicates when a system fault has

 

occurred at the control panel:

 

0

= System Normal – There are no

 

faults.

 

1

= System Fault – There is a fault

 

registered by the control panel.

Subscriber ID Number

This is the identification number of the control panel and can only be programmed by your installer.

Bosch Security Systems 6/04 920036O.OG.162

Image 17
Contents CC880/LP880, SC8016 Solution-16, Solution-16SafecomNotice of Liability Copyright NoticeNew Zealand Telepermit Notes CC880/LP880, SC8016 Operators GuideCC880/LP880, SC8016 Operators Guide Table of ContentsFigures CC880/LP880, SC8016 Operators Guide Tables3.0 Codepad Indicators Specifications1.0 Introduction Introduction3.2AWAY Indicator 3.1Zone Indicators3.3STAY Indicator Codepad Indicators3.6Off Indicator/Zone Sealed 3.5MAINS Indicator3.7On Indicator/Zone In Alarm 3.8FAULT Indicator4.2Arming in AWAY Mode 4.1Forced Arming4.3Arming in STAY Mode 4.4Arming in STAY Mode6.0 Adding User Codes 5.0 Disarming the System7.0Deleting User Codes 4.5Programming STAY Mode 2 Zones9.0 Codepad Panic Alarm 8.0 Codepad Duress Alarm10.0 Codepad Fire Alarm 11.0 Codepad Medical Alarm14.1Fault Descriptions 14.0 Fault Analysis ModeFault Analysis Mode 13.1Standard Isolating16.0 Turning Output Devices On/Off 15.0 Date and TimeDate and Time CC880/LP880, SC8016 Operators Guide18.0 Testing 17.0 Reset Latching Outputs20.0 Day Alarm Reset Latching Outputs21.0 Codepad ID and Buzzer Tone 22.1Master Partitioned Codepad Indicators22.0 Partitioning 22.2Operation of Codepads in PartitioningCC880/LP880, SC8016 Operators Guide 23.0 Remote Arming By Telephone22.3Arm/Disarm all Areas at the Same Time 25.0 Domestic Dialling 25.3Disable Domestic Dialling25.1Acknowledging Domestic Calls 25.2Programming Domestic Telephone Numbers27.0 Basic Pager Reporting 26.0 Domestic Voice Message Reporting27.1Basic Pager Display Information Domestic Voice MessageZone Normal - Alarm - Zone Bypassed Basic Pager ReportingPanic/Duress - Fire Alarm - Medical Alarm System FaultPET Pager Reporting 28.0 PET Pager ReportingCC880/LP880, SC8016 Operators Guide ENCC880/LP880, SC8016 Operators Guide 29.0 Glossary of TermsGlossary of Terms EN CC880/LP880, SC8016 Operators GuideGlossary of Terms Service Notes 30.0 Installation NotesInstallation Notes CC880/LP880, SC8016 Operators GuideInstallation Notes Zone DescriptionDay Alarm EnabledInstallation Notes User Code NamesDefault = 2580 User Code CC880/LP880, SC8016 Operators GuideArming Options Entry/Exit TimesOutput Descriptions Isolating MethodOther System Information Communication OptionsInstallation Notes CC880/LP880, SC8016 Operators GuideCC880/LP880, SC8016 Operators Guide Index IndexCC880/LP880, SC8016 Operators Guide Index Bosch Security Systems 6/04 920036O.OG.162 CC880/LP880, SC8016 Operators Guide IndexEN Bosch Security Systems 6/04 920036O.OG.162 CC880/LP880, SC8016 Operators Guide IndexEN Bosch Security Systems 6/04 920036O.OG.162 CC880/LP880, SC8016 Operators Guide IndexEN Bosch Security Systems 25 Huntingwood Drive 4998152460B IssueHuntingwood NSW Australia Phone +612 Facsimile +612