20 Error Messages
•Error 01 - Invalid camera request
The camera number entered from the keyboard does not exist. If using the optional LTC 8850 GUI Software or the optional LTC 8059 MCS, make sure the number exists in the Camera Identification Table. Download the table to be sure.
•Error 02 - Invalid monitor request
The monitor number entered from the keyboard does not exist. Enter a valid monitor number.
•Error 03 - Locked remote device
The remote device requested cannot be controlled because it is locked by a user with equal or higher priority. Check with the other users or request that a higher priority user unlock the remote device.
•Error 04 - Monitor locked
The monitor requested cannot be accessed because it is locked by a user with equal or higher priority. Check with the other users or request that a higher pri- ority user unlock the monitor.
•Error 05 - Remote device access restricted Remote locked out by Remote Lockout Table.
•Error 06 - Monitor Access Restricted Monitor locked out by Monitor Lockout Table.
•Error 10 - Access denied
A function was requested that requires a higher user priority. Only a Priority 2 user or a supervisor with Priority 1 may access this function.
•Error 11 - Access denied
A function was requested for which your user priority is too low. Only a super- visor with Priority 1 may access this function.
•Error 15 - Invalid user function
The function number requested from the keyboard is invalid. Refer to the User Function Table for a listing of the valid user function numbers.
•Error 20 - Acknowledge denied
The ACKNOWLEDGE button has been pressed by a user without the authority to acknowledge alarms.
•Error 21 - Incorrect acknowledge
In order to properly acknowledge an alarm event, the keyboard must be switched to a monitor that is displaying the alarms.
•Error 22 - Acknowledge disabled
Alarms on this monitor can not be acknowledged, because that capability has been disabled by the system programmer.
•Error 23 - Camera not in alarm
The camera displayed on the monitor is not an alarm video; only