CPU Software Version Numbers
ALARM INPUTS
The alarm inputs can be dry contact closures or logic levels. Connection to the Alarm unit is made to removable screw type terminal blocks and the use of simple twisted pair wire is acceptable.
C.4 Signal Distribution Unit
CONNECTION TO MAIN BAY
The Distribution unit is supplied with a 3 m long (10 ft) multiconductor cable with
DISTRIBUTION OUTPUTS
Only shielded twisted pair wire should be used between the Distribution unit and the camera site receiver/drivers. Connection to the Distribution unit is made to removable screw terminal type blocks. Each output is rated to handle up to eight receiver/driver loads as in a daisy chain configuration to a maximum of 1.5 km (5000 ft) using a 18 gauge wire (Belden 8760 or equivalent).
C.5 Receiver/Drivers
CODE INPUT
The code input is supplied by the shielded twisted pair cable from the Signal Distri- bution unit. This is connected to a removable screw terminal type block which has provisions for “looping” the code cable to another receiver/driver.
OUTPUT CONNECTIONS
All pan/tilt and lens connections will require multiconductor cable. Refer to the appropriate specification sheet for cable gage, number of conductors required, and maximum distances allowable. The lens cables and any
EN 87