EverFocus EPH5212 user manual 24VAC

Page 35

 

 

 

 

 

 

Issue: 1.0

 

 

 

 

 

 

 

Alarm

Inputs

4 NO/NC programmable trigger inputs; programmable relative priority of alarms

 

 

 

Alarm

Output

Form “C” relay rated at 12VDC/1A

 

 

 

 

Alarm

Actions

Go to preset, pattern, scan or tour;

optional programmable duration of 3~60 seconds

 

 

 

 

Other

Actions

On inactivity of 1~60 minutes,

go to preset position, pattern, scan or tour

 

 

 

RS-485 Protocols Supported

EVF-1, Pelco-P,

Pelco D

 

 

 

 

RS-485 Baud Rate

 

2400~38,400

 

 

 

 

 

 

RS-485 Addressing

Address

range

00~99

 

 

 

 

 

 

 

Power

Supply

24VAC

(+/-

10%

nominal)

2.5A capacity recommended (heater on); 1A recommended (heater off)

 

 

 

 

 

 

 

Power

Consumption

~850mA heater

off;

~1.8A heater on

 

 

 

 

 

 

 

Power

Input Surge Protection

 

Built

in

 

 

 

 

 

 

 

Body diameter 6.55”; height with wall arm 10”

Dimensions

Clear bubble

diameter 4.7”

 

 

Projection from rear with wall arm 13.4” (10.2” to center line of dome)

 

 

 

Weight

 

PTZ unit: 4.9 lbs; included EPH-WMB wall mount arm: 2.8 lbs.

 

 

Total in wall mount

configuration: 7.7 lbs.

 

 

Operating Temperature

-40°C~50°C ; -40°F~122°F (heater on below ~30°F)

 

 

 

Environmental

IP66

weather resistant

 

 

 

Mounting Provision

Wall mount arm

included

 

 

Certifications

FCC, CE, HDcctv Alliance Base-Line Compliance

 

 

 

 

 

 

 

 

35

Image 35
Contents User’s Manual Model EPH5212 HDcctv 12X IP66 Speed Dome Contents Important Safeguards Page Description FeaturesIssue Package Contents Installation and ConnectionBase Installation Connecting Alarms Connection Interface and Wiring cablesConnecting the RS-485 lines Connecting Video JackSetting the analog video format and RS-485 protocol Setting RS-485 ParametersSetting the address ID of dome camera SW302 SW301SW303 Issue Next Page Continue Page Editing a Title Accessing to Main Menu 95 + Preset/ MenuGetting Started System Information System Setup MenuMain Menu Initialize Entering a Password Display Setup MenuLanguage Page MD Motion Detection Camera Setup MenuImage Setup Focus/Zoom Page Shut PRI BLC/WDR/HSBLC/DNR Motion Setup General SetupHome Action Setup Calibration Setup Preset MenuPage Tour Menu Auto Scan Menu To save settings Settings Problem Solution Troubleshooting GuideGeneral Specifications Specifications24VAC Unit mm DimensionsPattern APPENDIX. RS-485 Function List