First Alert FA162C user manual Away, Stay, Instant, Bypass, Ready, No AC, Alarm

Page 11

ABOUT THE KEYPADS

 

Fixed-Word Keypad Displays

AWAY

All burglary zones, interior & perimeter, are armed.

STAY

Perimeter burglary zones, such as windows and doors

 

are armed.

INSTANT

Perimeter burglary zones armed and entry

 

delay is turned off.

BYPASS

One or more burglary protection zones have

 

been bypassed.

NOT READY Appears when burglary portion of the system is not

 

ready for arming (due to one or more open protection

 

zones).

READY

The burglary portion of the system is ready

 

to be armed.

NO AC

Appears when AC power has been cut off.

 

System is operating on backup battery power.

AC

Appears when AC power is present.

 

AWAY

NO AC

 

STAY

CHIME

ALARM

INSTANT

BAT

BYPASS

 

CHECK

 

NOT READY

FIRE

STYLE A KEYPAD DISPLAY

 

AWAY

NO AC

ALARM

BYPASS

NOT READY

STAY

CHIME BAT

FIRE CHECK INSTANT

STYLE B KEYPAD DISPLAY

CHIME Appears when the CHIME feature is ON.

BAT Low battery condition in a wireless sensor (if zone number displayed) or low system battery (if no zone number displayed).

ALARM Appears when an intrusion has been detected and the system is armed (also appears during a fire alarm or audible emergency alarm). Accompanied by the protection zone in alarm.

CHECK Appears when a malfunction is discovered in the system at any time or if an open is detected in a FIRE zone at any time or a fault in a DAY/NIGHT burglary zone during a disarmed period. Accompanied by a display of zone number in trouble.

FIRE Appears when a fire alarm is present. Accompanied by a display of the zone in alarm.

– 11 –

Image 11
Contents Users Manual Page Table of Contents System Overview Maximum AwayStay InstantPhone Access ENTRY/EXIT Delays Common Zone Operation About the Keypads FA450KP/FA550KP Alpha Keypads Instant AlarmAway StaySee Typical Alpha Keypad on Next Functions of the KeypadTypical Alpha Keypad System can be Armed Secure Faulted ZonesChecking for Open Zones Press the Ready KEYListen for 3 Beeps Arming Perimeter onlyEnter Security Code then Press Stay Enter Security Code then Press Instant With Entry Delay OFFListen Arming ALL ProtectionEnter Security Code then Press Away Enter Master Code then Press Away Twice Enter Security Code then Press Maximum Arming ALL ProtectionListen for 1 Beep Disarming and Silencing AlarmsEnter Security CODE, then Press OFF Wait Bypassing Protection ZonesEnter Security Code then Press Bypass Enter Zone NumbersBypassing Protection Zones View Chime ModeEnter Security Code then Press Chime Panic Keys For Manually Activating Silent AND/OR Audible Alarms+ Device Number Using Device CommandsEnter Security Code then Press # + 7 + Device Number Enter Security Code then Press #SSSS-EEE-NNN Paging FeatureSecurity Codes Code must be entered twice Disarm the System Testing the SystemFault Zones To be Conducted WeeklyExit Test Mode Or Check Trouble ConditionsModem Comm Call for Service AT OnceCall for Service Immediately System LO BATFire Alarm System if Installed Smoke Detectors for Minimum Protection Emergency Evacuation Steps to SafetyMaintaining Your System Maintaining Your System AWAY, STAY, Instant Maximum Function Procedure CommentsQuick Guide to Sound Cause Display Summary of Audible NotificationsAlpha Display Keypads Following terms are used throughout the manual GlossaryAvis Canadian Department of Communications DOC StatementGeneral Information Owners Insurance Premium Credit RequestOwners Insurance Premium Credit Request Event of Telephone Operational Problems Federal Communications Commission FCC Part 68 Notice Page Page Servicing Information Index ONE Year Limited Warranty ÀN7527-1V2!ä

FA162C specifications

The First Alert FA162C is a versatile and highly efficient fire extinguisher designed for home and business safety. Engineered to tackle multiple types of fires, this model ensures peace of mind with its robust features and innovative technologies.

One of the standout characteristics of the FA162C is its multi-purpose capability. It is classified to fight Class A, B, and C fires, making it suitable for use against ordinary combustibles like wood and paper, flammable liquids like grease and gasoline, and electrical fires involving live wires. This versatility is critical in everyday scenarios where the nature of a fire can vary, allowing users to handle emergencies effectively and safely.

This fire extinguisher features a durable metal construction, which enhances its longevity and reliability. The professional-grade valve and easy-to-pull safety pin provide user confidence during high-pressure moments. An important aspect of the FA162C is its pressure gauge, which allows users to easily monitor the readiness of the extinguisher at a glance. This feature is crucial for ensuring that the unit is always prepared for emergency situations.

The FA162C is equipped with a wide nozzle that creates a strong and effective stream, which can reach up to 10 feet, allowing users to maintain a safe distance from the fire while effectively combating it. Additionally, the lightweight design ensures ease of handling, making it manageable even for individuals who may not have experience using fire extinguishers.

For added safety, the FA162C comes with clear operating instructions directly on the label, promoting ease of use. First Alert also emphasizes the importance of regular maintenance, advising users to check their extinguishers monthly to ensure they remain in optimal condition.

With a compact design that offers portability, the First Alert FA162C can be conveniently placed in various locations, such as kitchens, garages, or vehicles. Overall, the First Alert FA162C epitomizes reliability and user-friendly design, making it a valuable addition for anyone looking to enhance their safety preparedness against fire hazards.