First Alert FA162C user manual Security Codes

Page 27

SECURITY CODES

General Information

Babysitter Code

Duress Code

Quick Arming

As an additional safety feature, other users who do not have a need to know your code can be assigned different security codes. These secondary users are identified by "user numbers," which are selected when assigning a user's security code. You can assign up to 14 additional user codes (user numbers 03-16), including the babysitter and duress codes. Note that the master (primary) user of the system is the only one who can assign codes to secondary (or temporary) users, and is user number 02; user number 01 is reserved for the installer of the system.

All codes can be used interchangeably when performing system functions (a system armed with one user's code can be disarmed by another user's code), with the exception of the babysitter code described below.

This code can be used to arm the system in assigned partitions, but cannot disarm the system unless the system was armed with this code. This code is typically assigned to someone (such as a babysitter) who has a need to arm/disarm the system only at certain times. The babysitter code is assigned to user 15. The user of this code should not use the “Quick Arming” feature described below.

This feature is intended for use when you are forced to disarm or arm the system under threat. When used, the system will act normally, but can silently notify the alarm monitoring company of your situation, if that service has been provided. Duress code is assigned to user 16.

Important: This code is useful only when the system is connected to a alarm monitoring company.

Note that if "Quick Arming" was programmed by the installer, the # key can be pressed in place of the security code when arming the system. The security code must always be used to disarm the system, however.

– 27 –

Image 27
Contents Users Manual Page Table of Contents System Overview Maximum AwayStay InstantPhone Access ENTRY/EXIT Delays Common Zone Operation About the Keypads FA450KP/FA550KP Alpha Keypads Instant AlarmAway StaySee Typical Alpha Keypad on Next Functions of the KeypadTypical Alpha Keypad System can be Armed Secure Faulted ZonesChecking for Open Zones Press the Ready KEYArming Perimeter only Enter Security Code then Press StayListen for 3 Beeps Enter Security Code then Press Instant With Entry Delay OFFArming ALL Protection Enter Security Code then Press AwayListen Enter Master Code then Press Away Twice Enter Security Code then Press Maximum Arming ALL ProtectionDisarming and Silencing Alarms Enter Security CODE, then Press OFFListen for 1 Beep Wait Bypassing Protection ZonesEnter Security Code then Press Bypass Enter Zone NumbersBypassing Protection Zones Chime Mode Enter Security Code then Press ChimeView Panic Keys For Manually Activating Silent AND/OR Audible Alarms+ Device Number Using Device CommandsEnter Security Code then Press # + 7 + Device Number Enter Security Code then Press #SSSS-EEE-NNN Paging FeatureSecurity Codes Code must be entered twice Disarm the System Testing the SystemFault Zones To be Conducted WeeklyExit Test Mode Or Check Trouble ConditionsModem Comm Call for Service AT OnceCall for Service Immediately System LO BATFire Alarm System if Installed Smoke Detectors for Minimum Protection Emergency Evacuation Steps to SafetyMaintaining Your System Maintaining Your System AWAY, STAY, Instant Maximum Function Procedure CommentsQuick Guide to Summary of Audible Notifications Alpha Display KeypadsSound Cause Display Following terms are used throughout the manual GlossaryAvis Canadian Department of Communications DOC StatementGeneral Information Owners Insurance Premium Credit RequestOwners Insurance Premium Credit Request Event of Telephone Operational Problems Federal Communications Commission FCC Part 68 Notice Page Page Servicing Information Index ONE Year Limited Warranty ÀN7527-1V2!ä

FA162C specifications

The First Alert FA162C is a versatile and highly efficient fire extinguisher designed for home and business safety. Engineered to tackle multiple types of fires, this model ensures peace of mind with its robust features and innovative technologies.

One of the standout characteristics of the FA162C is its multi-purpose capability. It is classified to fight Class A, B, and C fires, making it suitable for use against ordinary combustibles like wood and paper, flammable liquids like grease and gasoline, and electrical fires involving live wires. This versatility is critical in everyday scenarios where the nature of a fire can vary, allowing users to handle emergencies effectively and safely.

This fire extinguisher features a durable metal construction, which enhances its longevity and reliability. The professional-grade valve and easy-to-pull safety pin provide user confidence during high-pressure moments. An important aspect of the FA162C is its pressure gauge, which allows users to easily monitor the readiness of the extinguisher at a glance. This feature is crucial for ensuring that the unit is always prepared for emergency situations.

The FA162C is equipped with a wide nozzle that creates a strong and effective stream, which can reach up to 10 feet, allowing users to maintain a safe distance from the fire while effectively combating it. Additionally, the lightweight design ensures ease of handling, making it manageable even for individuals who may not have experience using fire extinguishers.

For added safety, the FA162C comes with clear operating instructions directly on the label, promoting ease of use. First Alert also emphasizes the importance of regular maintenance, advising users to check their extinguishers monthly to ensure they remain in optimal condition.

With a compact design that offers portability, the First Alert FA162C can be conveniently placed in various locations, such as kitchens, garages, or vehicles. Overall, the First Alert FA162C epitomizes reliability and user-friendly design, making it a valuable addition for anyone looking to enhance their safety preparedness against fire hazards.