TESTING THE SYSTEM

5.

(Security Code)

+

OFF

1

Walk in front of any interior motion detectors (if used) and listen for three beeps. The identification of the detector should appear on the display when it is activated. The display will clear when no motion is detected. Note that if wireless motion detectors are used, there is a 3-minute delay between activations. This is to conserve battery life.

To test all smoke detectors, follow the manufacturer's instructions. The identification of each detector should appear on the display when each is activated.

If a problem is experienced with any protection point (no confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY .

When all protection points have been checked and are intact (closed), there should be no zone identification numbers displayed on the keypad

When testing is completed, exit the TEST mode by continuing with step 5.

EXIT TEST MODE

Enter your security code and press the OFF key.

If the test mode is inadvertently left active, it automatically turns off after 4 hours.

– 30 –

Image 30
Contents Users Manual Page Table of Contents System Overview Instant AwayStay MaximumPhone Access ENTRY/EXIT Delays Common Zone Operation About the Keypads FA450KP/FA550KP Alpha Keypads Stay AlarmAway InstantFunctions of the Keypad See Typical Alpha Keypad on NextTypical Alpha Keypad Press the Ready KEY Secure Faulted ZonesChecking for Open Zones System can be ArmedArming Perimeter only Enter Security Code then Press StayListen for 3 Beeps With Entry Delay OFF Enter Security Code then Press InstantArming ALL Protection Enter Security Code then Press AwayListen Enter Master Code then Press Away Twice Arming ALL Protection Enter Security Code then Press MaximumDisarming and Silencing Alarms Enter Security CODE, then Press OFFListen for 1 Beep Enter Zone Numbers Bypassing Protection ZonesEnter Security Code then Press Bypass WaitBypassing Protection Zones Chime Mode Enter Security Code then Press ChimeView For Manually Activating Silent AND/OR Audible Alarms Panic KeysEnter Security Code then Press # Using Device CommandsEnter Security Code then Press # + 7 + Device Number + Device NumberPaging Feature SSSS-EEE-NNNSecurity Codes Code must be entered twice To be Conducted Weekly Testing the SystemFault Zones Disarm the SystemExit Test Mode Trouble Conditions Or CheckSystem LO BAT Call for Service AT OnceCall for Service Immediately Modem CommFire Alarm System if Installed Smoke Detectors for Minimum Protection Steps to Safety Emergency EvacuationMaintaining Your System Maintaining Your System Function Procedure Comments AWAY, STAY, Instant MaximumQuick Guide to Summary of Audible Notifications Alpha Display KeypadsSound Cause Display Glossary Following terms are used throughout the manualCanadian Department of Communications DOC Statement AvisOwners Insurance Premium Credit Request General InformationOwners Insurance Premium Credit Request Event of Telephone Operational Problems Federal Communications Commission FCC Part 68 Notice Page Page Servicing Information Index ONE Year Limited Warranty ÀN7527-1V2!ä

FA162C specifications

The First Alert FA162C is a versatile and highly efficient fire extinguisher designed for home and business safety. Engineered to tackle multiple types of fires, this model ensures peace of mind with its robust features and innovative technologies.

One of the standout characteristics of the FA162C is its multi-purpose capability. It is classified to fight Class A, B, and C fires, making it suitable for use against ordinary combustibles like wood and paper, flammable liquids like grease and gasoline, and electrical fires involving live wires. This versatility is critical in everyday scenarios where the nature of a fire can vary, allowing users to handle emergencies effectively and safely.

This fire extinguisher features a durable metal construction, which enhances its longevity and reliability. The professional-grade valve and easy-to-pull safety pin provide user confidence during high-pressure moments. An important aspect of the FA162C is its pressure gauge, which allows users to easily monitor the readiness of the extinguisher at a glance. This feature is crucial for ensuring that the unit is always prepared for emergency situations.

The FA162C is equipped with a wide nozzle that creates a strong and effective stream, which can reach up to 10 feet, allowing users to maintain a safe distance from the fire while effectively combating it. Additionally, the lightweight design ensures ease of handling, making it manageable even for individuals who may not have experience using fire extinguishers.

For added safety, the FA162C comes with clear operating instructions directly on the label, promoting ease of use. First Alert also emphasizes the importance of regular maintenance, advising users to check their extinguishers monthly to ensure they remain in optimal condition.

With a compact design that offers portability, the First Alert FA162C can be conveniently placed in various locations, such as kitchens, garages, or vehicles. Overall, the First Alert FA162C epitomizes reliability and user-friendly design, making it a valuable addition for anyone looking to enhance their safety preparedness against fire hazards.