First Alert FA162C user manual Bypassing Protection Zones

Page 22

BYPASSING PROTECTION ZONES (Continued)

Quick Bypass Your system may allow you to easily bypass all open (faulted) zones without having to enter zone numbers individually. Ask your installer if this feature is active.

All open (faulted) zones

All open zones, plus these zones as checked:

BYPASS

17

30

31

1. + 6

(Security Code)

2.BYPASS 07 F RONT UPST AIRS BE DROOM

Typical bypass message

3.DISARME D BYPASS RE ADY T O ARM

ENTER SECURITY CODE THEN PRESS BYPASS

Example: 7 2 9 6 then press the BYPASS key.

WAIT. In a few moments, all open zones will be displayed along with the word BYPASS. Wait for these zones to be displayed before arming. Arming the system before zones are displayed eliminates all bypasses.

ARM AS USUAL. Arm the system as usual when the keypad displays the "Ready" message.

Displaying Bypassed

Previously bypassed zones can be displayed only when the system is disarmed, and when the

Zones

“Bypass” message shown in step 3 above is displayed.

 

BYPASS

1.

2.

+ 6

(Security Code)

BYPASS 07 F RONT UPST AIRS BE DROOM

Typical bypass message

ENTER SECURITY CODE THEN PRESS BYPASS

Example: 7 2 9 6 then press the BYPASS key.

WAIT

In a few moments, all open zones will be sequentially displayed along with the word BYPASS.

– 22 –

Image 22
Contents Users Manual Page Table of Contents System Overview Instant AwayStay MaximumPhone Access ENTRY/EXIT Delays Common Zone Operation About the Keypads FA450KP/FA550KP Alpha Keypads Stay AlarmAway InstantFunctions of the Keypad See Typical Alpha Keypad on NextTypical Alpha Keypad Press the Ready KEY Secure Faulted ZonesChecking for Open Zones System can be ArmedEnter Security Code then Press Stay Arming Perimeter onlyListen for 3 Beeps With Entry Delay OFF Enter Security Code then Press InstantEnter Security Code then Press Away Arming ALL ProtectionListen Enter Master Code then Press Away Twice Arming ALL Protection Enter Security Code then Press MaximumEnter Security CODE, then Press OFF Disarming and Silencing AlarmsListen for 1 Beep Enter Zone Numbers Bypassing Protection ZonesEnter Security Code then Press Bypass WaitBypassing Protection Zones Enter Security Code then Press Chime Chime ModeView For Manually Activating Silent AND/OR Audible Alarms Panic KeysEnter Security Code then Press # Using Device CommandsEnter Security Code then Press # + 7 + Device Number + Device NumberPaging Feature SSSS-EEE-NNNSecurity Codes Code must be entered twice To be Conducted Weekly Testing the SystemFault Zones Disarm the SystemExit Test Mode Trouble Conditions Or CheckSystem LO BAT Call for Service AT OnceCall for Service Immediately Modem CommFire Alarm System if Installed Smoke Detectors for Minimum Protection Steps to Safety Emergency EvacuationMaintaining Your System Maintaining Your System Function Procedure Comments AWAY, STAY, Instant MaximumQuick Guide to Alpha Display Keypads Summary of Audible NotificationsSound Cause Display Glossary Following terms are used throughout the manualCanadian Department of Communications DOC Statement AvisOwners Insurance Premium Credit Request General InformationOwners Insurance Premium Credit Request Event of Telephone Operational Problems Federal Communications Commission FCC Part 68 Notice Page Page Servicing Information Index ONE Year Limited Warranty ÀN7527-1V2!ä

FA162C specifications

The First Alert FA162C is a versatile and highly efficient fire extinguisher designed for home and business safety. Engineered to tackle multiple types of fires, this model ensures peace of mind with its robust features and innovative technologies.

One of the standout characteristics of the FA162C is its multi-purpose capability. It is classified to fight Class A, B, and C fires, making it suitable for use against ordinary combustibles like wood and paper, flammable liquids like grease and gasoline, and electrical fires involving live wires. This versatility is critical in everyday scenarios where the nature of a fire can vary, allowing users to handle emergencies effectively and safely.

This fire extinguisher features a durable metal construction, which enhances its longevity and reliability. The professional-grade valve and easy-to-pull safety pin provide user confidence during high-pressure moments. An important aspect of the FA162C is its pressure gauge, which allows users to easily monitor the readiness of the extinguisher at a glance. This feature is crucial for ensuring that the unit is always prepared for emergency situations.

The FA162C is equipped with a wide nozzle that creates a strong and effective stream, which can reach up to 10 feet, allowing users to maintain a safe distance from the fire while effectively combating it. Additionally, the lightweight design ensures ease of handling, making it manageable even for individuals who may not have experience using fire extinguishers.

For added safety, the FA162C comes with clear operating instructions directly on the label, promoting ease of use. First Alert also emphasizes the importance of regular maintenance, advising users to check their extinguishers monthly to ensure they remain in optimal condition.

With a compact design that offers portability, the First Alert FA162C can be conveniently placed in various locations, such as kitchens, garages, or vehicles. Overall, the First Alert FA162C epitomizes reliability and user-friendly design, making it a valuable addition for anyone looking to enhance their safety preparedness against fire hazards.