First Alert FA145C user manual Bypassing Protection Zones, Using Bypass Key, To Bypass Zones

Page 14

BYPASSING PROTECTION ZONES

Using the

6BYPASS Key

LIMITATION

The system will not allow fire zones to be bypassed.

All bypasses are removed when an OFF sequence (security code plus OFF) is performed.

This key is used when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first.

1.Enter your security code and press the BYPASS key.

2.Enter the zone number(s) for the zone(s) to be bypassed (e.g., 06, 10, 13, etc.). Single digit zone numbers must be preceded by a zero (e.g. 05, 06).

3.When finished, the keypad will momentarily display a "Bypass" message for each by- passed zone number. Wait for these zones to be displayed, to confirm their bypass.

4.Arm the system as usual.

Bypassed zones are unprotected and will not cause an alarm if violated while your system is armed.

TO BYPASS ZONES:

ENTER CODE.

PRESS BYPASS KEY.

ENTER ZONE Nos.

WAIT FOR BYPASSED ZONES TO BE DISPLAYED.

ARM SYSTEM AS USUAL.

TYPICAL MOMENTARY DISPLAYS

OF BYPASSED ZONE

BYPASS 06 FRONT UPSTAIRS BEDROOM

 

 

ALPHA

 

 

 

 

 

ÊÊ06

AC

 

 

BYPASS

 

 

 

 

 

 

 

 

 

FIXED-WORD

– 14 –

Image 14
Contents First Alert Table of Contents System Overview Fire Protection Chime Feature System OverviewFixed-Word Keypads About the KeypadsAlpha Keypads BAT AlarmChime CheckStyle a Display Style B Display Functions of the Keypad Typical Alpha Keypad Security Codes General To Assign, Change, or Delete User CodesTo Change Your Master Code Security CodesDuress Code Phone Voice ModuleENTRY/EXIT Delays Exit Delay Seconds Entry Delay NoTo Display Open ZONES, Press Using the Ready KeyChecking for Open Zones To Bypass Zones Using Bypass KeyBypassing Protection Zones Bypassing Protection Zones Quick BypassStay Using Stay KeyArming Perimeter only Using Instant KeyArming ALL Protection Using Away KeyUse this key when no one will be staying inside Maximum KEY Using Maximum KeyAn alarm sounds immediately, when someone re-enters Away ACDisarming the System and Silencing Alarms Using OFF KeyUsing Chime Key Exit AlarmsChime Mode For Manually Activating Silent AND/OR Audible Alarms Panic KeysResponse to zone activity or manual entries Panic KeysOutput Relay Options Testing the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsCOMM. Failure Trouble ConditionsOther Trouble Displays System LO BATDisabled. Call for Service Immediately AC LossFire Alarm System if Installed 05 ACManually Initiating Fire Alarm SystemFire Alarm Press the key pair assigned for Fire emergencySmoke Detectors for Minimum Protection Steps to Safety Emergency EvacuationFunction Procedure Comments Quick Guide to System FunctionsSummary of AUDIBLE/VISUAL Notifications Alpha Display KeypadsFIXED-WORD Display Keypads Zone Description Protection Zones ListProtection Zone Descriptions Owners Insurance Premium Credit Request Owners Insurance Premium Canadian Department of Communications DOC Statement AvisUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA145C specifications

The First Alert FA145C is an innovative smoke and carbon monoxide detector designed to enhance safety in residential settings. This intelligent device combines advanced technology with user-friendly features, ensuring that homeowners can protect their families from fire and toxic gas threats effectively.

At the core of the FA145C is its dual-sensor technology, which utilizes both photoelectric and ionization sensors. The photoelectric sensor excels at detecting smoldering fires, often caused by burning materials like mattresses and upholstery, while the ionization sensor is highly effective in identifying flaming fires, such as those ignited by paper or flammable liquids. This combination results in faster response times to a wider range of fire types, significantly increasing safety within the home.

The FA145C also features a built-in carbon monoxide detector, providing an added layer of protection against this odorless and colorless gas. Carbon monoxide is a byproduct of burning fossil fuels, and exposure can lead to serious health hazards. The incorporation of CO detection in one device simplifies the safety measures in a home and ensures comprehensive monitoring.

A standout feature of the First Alert FA145C is its voice alert system. This system provides clear announcements, indicating whether smoke or carbon monoxide has been detected. By minimizing confusion during emergencies, the voice alerts allow for quicker and more informed reactions, particularly in a panic-inducing situation.

The unit is equipped with a 10-year battery life, which reduces the hassle and costs associated with frequent replacements. The long-lasting battery ensures that the device remains operational for an extended period, contributing to peace of mind for homeowners. Additionally, the FA145C includes a convenient battery status indicator, alerting users when the battery is running low.

Installation is straightforward, thanks to the user-friendly design and included mounting hardware. The sleek, modern appearance of the FA145C allows it to blend seamlessly with various interior styles, making it a practical choice for any home.

Overall, the First Alert FA145C stands out as a crucial safety tool, integrating advanced sensors, voice alerts, and long battery life into a single device. This smoke and carbon monoxide detector sets a high standard for residential safety, offering homeowners both reassurance and protection against potential hazards.