First Alert FA145C user manual Table of Contents

Page 2

TABLE OF CONTENTS

SYSTEM OVERVIEW

3

General

3

Zones

3

Burglary Protection

3

Chime Feature

3

Alarms

4

Fire Protection

4

Memory of Alarm

4

Phone Access & Voice Response Capability

4

Paging Feature

4

ABOUT THE KEYPADS

5

Keypad Styles

5

Keypad Types

5

FUNCTIONS OF THE KEYPAD

8

SECURITY CODES

10

To Assign, Change, or Delete User Codes

10

Duress Code

11

To Change Your Master Code

11

Quick Arming

11

Phone (Voice) Module

11

ENTRY/EXIT DELAYS

12

General

12

Exit Delay Alerting Sound

12

CHECKING FOR OPEN ZONES

13

BYPASSING PROTECTION ZONES

14

Using the BYPASS Key

14

Quick Bypass

15

ARMING PERIMETER ONLY (STAY)

16

ARMING PERIMETER ONLY (INSTANT)

17

ARMING ALL PROTECTION (AWAY)

18

ARMING ALL PROTECTION (MAXIMUM)

19

DISARMING THE SYSTEM AND SILENCING ALARMS

20

EXIT ALARMS

21

CHIME MODE

21

PANIC KEYS

22

OUTPUT RELAY OPTIONS

23

TESTING THE SYSTEM

24

PAGING FEATURE

25

TROUBLE CONDITIONS

26

"CHECK" and "BATTERY" Displays

26

Other Trouble Displays

27

Total Power Failure

28

CALLING FOR SERVICE

28

FIRE ALARM SYSTEM (IF INSTALLED)

29

Silencing Fire Alarms

29

Manually Initiating a Fire Alarm

30

NFPA RECOMMENDATIONS ON SMOKE DETECTORS

31

EMERGENCY EVACUATION

32

QUICK GUIDE TO SYSTEM FUNCTIONS

33

SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS

34

Alpha Display Keypads

34

Fixed-Word Display Keypads

35

PROTECTION ZONES LIST

36

OWNER’S INSURANCE CREDIT REQUEST FORM

37

CANADIAN (DOC) STATEMENT

39

FCC STATEMENTS

40

LIMITATIONS STATEMENT

42

WARRANTY

Back Cover

This manual is a step-by-step guide that will acquaint you with the system's features and benefits. It defines the components and their functions, describes their operation, and provides clear step-by-step instructions for normal and emergency procedures.

Keep this manual in a convenient place so that you can refer to it as necessary.

– 2 –

Image 2
Contents First Alert Table of Contents System Overview Fire Protection Chime Feature System OverviewFixed-Word Keypads About the KeypadsAlpha Keypads BAT AlarmChime CheckStyle a Display Style B Display Functions of the Keypad Typical Alpha Keypad Security Codes General To Assign, Change, or Delete User CodesTo Change Your Master Code Security CodesDuress Code Phone Voice ModuleENTRY/EXIT Delays Exit Delay Seconds Entry Delay NoTo Display Open ZONES, Press Using the Ready KeyChecking for Open Zones To Bypass Zones Using Bypass KeyBypassing Protection Zones Bypassing Protection Zones Quick BypassStay Using Stay KeyArming Perimeter only Using Instant KeyArming ALL Protection Using Away KeyUse this key when no one will be staying inside Maximum KEY Using Maximum KeyAn alarm sounds immediately, when someone re-enters Away ACDisarming the System and Silencing Alarms Using OFF KeyUsing Chime Key Exit AlarmsChime Mode For Manually Activating Silent AND/OR Audible Alarms Panic KeysResponse to zone activity or manual entries Panic KeysOutput Relay Options Testing the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsCOMM. Failure Trouble ConditionsOther Trouble Displays System LO BATDisabled. Call for Service Immediately AC LossFire Alarm System if Installed 05 ACManually Initiating Fire Alarm SystemFire Alarm Press the key pair assigned for Fire emergencySmoke Detectors for Minimum Protection Steps to Safety Emergency EvacuationFunction Procedure Comments Quick Guide to System FunctionsSummary of AUDIBLE/VISUAL Notifications Alpha Display KeypadsFIXED-WORD Display Keypads Zone Description Protection Zones ListProtection Zone Descriptions Owners Insurance Premium Credit Request Owners Insurance Premium Canadian Department of Communications DOC Statement AvisUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA145C specifications

The First Alert FA145C is an innovative smoke and carbon monoxide detector designed to enhance safety in residential settings. This intelligent device combines advanced technology with user-friendly features, ensuring that homeowners can protect their families from fire and toxic gas threats effectively.

At the core of the FA145C is its dual-sensor technology, which utilizes both photoelectric and ionization sensors. The photoelectric sensor excels at detecting smoldering fires, often caused by burning materials like mattresses and upholstery, while the ionization sensor is highly effective in identifying flaming fires, such as those ignited by paper or flammable liquids. This combination results in faster response times to a wider range of fire types, significantly increasing safety within the home.

The FA145C also features a built-in carbon monoxide detector, providing an added layer of protection against this odorless and colorless gas. Carbon monoxide is a byproduct of burning fossil fuels, and exposure can lead to serious health hazards. The incorporation of CO detection in one device simplifies the safety measures in a home and ensures comprehensive monitoring.

A standout feature of the First Alert FA145C is its voice alert system. This system provides clear announcements, indicating whether smoke or carbon monoxide has been detected. By minimizing confusion during emergencies, the voice alerts allow for quicker and more informed reactions, particularly in a panic-inducing situation.

The unit is equipped with a 10-year battery life, which reduces the hassle and costs associated with frequent replacements. The long-lasting battery ensures that the device remains operational for an extended period, contributing to peace of mind for homeowners. Additionally, the FA145C includes a convenient battery status indicator, alerting users when the battery is running low.

Installation is straightforward, thanks to the user-friendly design and included mounting hardware. The sleek, modern appearance of the FA145C allows it to blend seamlessly with various interior styles, making it a practical choice for any home.

Overall, the First Alert FA145C stands out as a crucial safety tool, integrating advanced sensors, voice alerts, and long battery life into a single device. This smoke and carbon monoxide detector sets a high standard for residential safety, offering homeowners both reassurance and protection against potential hazards.