First Alert FA145C user manual ENTRY/EXIT Delays, Exit Delay Seconds Entry Delay No

Page 12

ENTRY/EXIT DELAYS

General Information Your system has preset time delays, known as exit delay and entry delay. When you arm your system, exit delay gives you time to leave through the entry/exit door without setting off an alarm. Entry delay gives you time to disarm the system when you re-enter through the entry/exit door. The system must be disarmed, however, before the entry delay period ends, or an alarm will occur. The keypad will beep slowly during the entry delay period, reminding you to disarm the system.

There are two entry delays (as programmed). The first is generally used for your primary entrance and the second can be used for a secondary entrance, where a longer delay may be required to walk to the keypad to disarm the system.

You can also arm the system with no entry delay at all by using either INSTANT or MAXIMUM arming modes. These modes can provide greater security while you are sleeping or while you are away for extended periods of time.

See your installer for your programmed delay times and record them here:

Exit Delay:

seconds Entry Delay No. 1:

Entry Delay No. 2:

seconds

seconds

Remember, there will be no entry delay when arming INSTANT or MAXIMUM.

Exit Delay When arming the system AWAY (see page 18) or MAXIMUM (see page 19), slow Alerting warning tones will sound from the keypad(s) as a warning during the exit delay, turning to

Sound fast tones during the final five seconds of the exit delay time.

Ask your installer if this feature is active for your system, and if so, check here:

– 12 –

Image 12
Contents First Alert Table of Contents System Overview Fire Protection Chime Feature System OverviewAbout the Keypads Alpha KeypadsFixed-Word Keypads Alarm ChimeBAT CheckStyle a Display Style B Display Functions of the Keypad Typical Alpha Keypad Security Codes General To Assign, Change, or Delete User CodesSecurity Codes Duress CodeTo Change Your Master Code Phone Voice ModuleENTRY/EXIT Delays Exit Delay Seconds Entry Delay NoUsing the Ready Key Checking for Open ZonesTo Display Open ZONES, Press Using Bypass Key Bypassing Protection ZonesTo Bypass Zones Bypassing Protection Zones Quick BypassUsing Stay Key Arming Perimeter onlyStay Using Instant KeyUsing Away Key Use this key when no one will be staying insideArming ALL Protection Using Maximum Key An alarm sounds immediately, when someone re-entersMaximum KEY Away ACDisarming the System and Silencing Alarms Using OFF KeyExit Alarms Chime ModeUsing Chime Key For Manually Activating Silent AND/OR Audible Alarms Panic KeysPanic Keys Output Relay OptionsResponse to zone activity or manual entries Testing the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsTrouble Conditions Other Trouble DisplaysCOMM. Failure System LO BATDisabled. Call for Service Immediately AC LossFire Alarm System if Installed 05 ACFire Alarm System Fire AlarmManually Initiating Press the key pair assigned for Fire emergencySmoke Detectors for Minimum Protection Steps to Safety Emergency EvacuationFunction Procedure Comments Quick Guide to System FunctionsSummary of AUDIBLE/VISUAL Notifications Alpha Display KeypadsFIXED-WORD Display Keypads Protection Zones List Protection Zone DescriptionsZone Description Owners Insurance Premium Credit Request Owners Insurance Premium Canadian Department of Communications DOC Statement AvisUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA145C specifications

The First Alert FA145C is an innovative smoke and carbon monoxide detector designed to enhance safety in residential settings. This intelligent device combines advanced technology with user-friendly features, ensuring that homeowners can protect their families from fire and toxic gas threats effectively.

At the core of the FA145C is its dual-sensor technology, which utilizes both photoelectric and ionization sensors. The photoelectric sensor excels at detecting smoldering fires, often caused by burning materials like mattresses and upholstery, while the ionization sensor is highly effective in identifying flaming fires, such as those ignited by paper or flammable liquids. This combination results in faster response times to a wider range of fire types, significantly increasing safety within the home.

The FA145C also features a built-in carbon monoxide detector, providing an added layer of protection against this odorless and colorless gas. Carbon monoxide is a byproduct of burning fossil fuels, and exposure can lead to serious health hazards. The incorporation of CO detection in one device simplifies the safety measures in a home and ensures comprehensive monitoring.

A standout feature of the First Alert FA145C is its voice alert system. This system provides clear announcements, indicating whether smoke or carbon monoxide has been detected. By minimizing confusion during emergencies, the voice alerts allow for quicker and more informed reactions, particularly in a panic-inducing situation.

The unit is equipped with a 10-year battery life, which reduces the hassle and costs associated with frequent replacements. The long-lasting battery ensures that the device remains operational for an extended period, contributing to peace of mind for homeowners. Additionally, the FA145C includes a convenient battery status indicator, alerting users when the battery is running low.

Installation is straightforward, thanks to the user-friendly design and included mounting hardware. The sleek, modern appearance of the FA145C allows it to blend seamlessly with various interior styles, making it a practical choice for any home.

Overall, the First Alert FA145C stands out as a crucial safety tool, integrating advanced sensors, voice alerts, and long battery life into a single device. This smoke and carbon monoxide detector sets a high standard for residential safety, offering homeowners both reassurance and protection against potential hazards.