FUNCTIONS OF THE KEYPAD

1DISPLAY WINDOW. Alpha Keypad: A 2-line,32-character Liquid Crystal Display (LCD). Displays protection zone identification, system status, and messages (see page 9).

Fixed-Word Keypad: Displays protection zone ID and system status messages using pre-designated words (see page 6).

2.OFF KEY: Disarms the burglary portion of the system, silences alarms and audible trouble indicators, and clears visual displays after the problem's correction.

3.AWAY KEY: Arms the entire burglary system, perimeter and interior, with entry delay on.

4.STAY KEY: Arms the perimeter portion of burglary system only, with entry delay on. Interior protection zones are not armed, which allows movement within the premises without causing an alarm.

5.MAXIMUM KEY: Arms in a manner similar to the AWAY mode, but without the entry delay feature, thus providing maximum protection. An alarm will occur immediately upon opening of any protection point, including the main door.

6.TEST KEY: Tests the system and alarm sounder (system must be disarmed). Refer to TESTING THE SYSTEM for test procedures.

7.BYPASS KEY: Removes individual protection zones from being monitored by the system.

8.INSTANT KEY: Arms in a manner similar to the STAY mode, but without the entry delay feature. Entering via the entry/exit door will cause an instant alarm.

9.CODE KEY: Used to assign additional security codes for other users of the system.

10.CHIME KEY: Turns CHIME mode on and off. When on, the opening of windows or doors while the system is disarmed will sound 3 tones at the keypad(s).

11. READY KEY: Displays all open protection zones.

12.# KEY: "Quick Arm" key permits ARMING of the system without the use of a security code (if so programmed).

13.KEYS 0–9:Used to enter your security code(s).

14.READY INDICATOR: (GREEN) Lit when the system is ready to be armed (no faults present). While the system is disarmed, this indicator will go on and off as protection zones are closed and opened.

15.ARMED INDICATOR: (RED) Lit when the system has been armed (STAY, AWAY, INSTANT or MAXIMUM).

16.INTERNAL SOUNDER: The built-in keypad sounder mimics the alarm sounder during alarms, and will also sound a tone during certain system functions.

17.EMERGENCY (PANIC) KEYS: On certain keypads, individual keys A , B, and C are present and may be used for emergency functions, if so programmed. On some keypads, individual panic keys are not present and certain key pairs may be available for emergency functions.

In addition, key D or key pair [] & [#] may have been programmed to request service from the central monitoring station.

See the PANIC KEYS section for complete details.

Note: Keys [ 1] through [9] each perform their associated companion functions (OFF, AWAY, STAY, etc.) when preceded by an entry of the security code (as described later).

– 8 –

Image 8
Contents First Alert Table of Contents System Overview Fire Protection Chime Feature System OverviewFixed-Word Keypads About the KeypadsAlpha Keypads Alarm ChimeBAT CheckStyle a Display Style B Display Functions of the Keypad Typical Alpha Keypad Security Codes General To Assign, Change, or Delete User CodesSecurity Codes Duress CodeTo Change Your Master Code Phone Voice ModuleENTRY/EXIT Delays Exit Delay Seconds Entry Delay NoTo Display Open ZONES, Press Using the Ready KeyChecking for Open Zones To Bypass Zones Using Bypass KeyBypassing Protection Zones Bypassing Protection Zones Quick BypassStay Using Stay KeyArming Perimeter only Using Instant KeyArming ALL Protection Using Away KeyUse this key when no one will be staying inside Using Maximum Key An alarm sounds immediately, when someone re-entersMaximum KEY Away ACDisarming the System and Silencing Alarms Using OFF KeyUsing Chime Key Exit AlarmsChime Mode For Manually Activating Silent AND/OR Audible Alarms Panic KeysResponse to zone activity or manual entries Panic KeysOutput Relay Options Testing the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsTrouble Conditions Other Trouble DisplaysCOMM. Failure System LO BATDisabled. Call for Service Immediately AC LossFire Alarm System if Installed 05 ACFire Alarm System Fire AlarmManually Initiating Press the key pair assigned for Fire emergencySmoke Detectors for Minimum Protection Steps to Safety Emergency EvacuationFunction Procedure Comments Quick Guide to System FunctionsSummary of AUDIBLE/VISUAL Notifications Alpha Display KeypadsFIXED-WORD Display Keypads Zone Description Protection Zones ListProtection Zone Descriptions Owners Insurance Premium Credit Request Owners Insurance Premium Canadian Department of Communications DOC Statement AvisUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA145C specifications

The First Alert FA145C is an innovative smoke and carbon monoxide detector designed to enhance safety in residential settings. This intelligent device combines advanced technology with user-friendly features, ensuring that homeowners can protect their families from fire and toxic gas threats effectively.

At the core of the FA145C is its dual-sensor technology, which utilizes both photoelectric and ionization sensors. The photoelectric sensor excels at detecting smoldering fires, often caused by burning materials like mattresses and upholstery, while the ionization sensor is highly effective in identifying flaming fires, such as those ignited by paper or flammable liquids. This combination results in faster response times to a wider range of fire types, significantly increasing safety within the home.

The FA145C also features a built-in carbon monoxide detector, providing an added layer of protection against this odorless and colorless gas. Carbon monoxide is a byproduct of burning fossil fuels, and exposure can lead to serious health hazards. The incorporation of CO detection in one device simplifies the safety measures in a home and ensures comprehensive monitoring.

A standout feature of the First Alert FA145C is its voice alert system. This system provides clear announcements, indicating whether smoke or carbon monoxide has been detected. By minimizing confusion during emergencies, the voice alerts allow for quicker and more informed reactions, particularly in a panic-inducing situation.

The unit is equipped with a 10-year battery life, which reduces the hassle and costs associated with frequent replacements. The long-lasting battery ensures that the device remains operational for an extended period, contributing to peace of mind for homeowners. Additionally, the FA145C includes a convenient battery status indicator, alerting users when the battery is running low.

Installation is straightforward, thanks to the user-friendly design and included mounting hardware. The sleek, modern appearance of the FA145C allows it to blend seamlessly with various interior styles, making it a practical choice for any home.

Overall, the First Alert FA145C stands out as a crucial safety tool, integrating advanced sensors, voice alerts, and long battery life into a single device. This smoke and carbon monoxide detector sets a high standard for residential safety, offering homeowners both reassurance and protection against potential hazards.