First Alert FA145C user manual Arming ALL Protection, Using Away Key

Page 18

Using the

2AWAY Key

BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13.

ARMING ALL PROTECTION

WITH ENTRY DELAY ON

Use this key when no one will be staying inside.

1. Enter your security code and press the AWAY key.

2.The keypad beeps twice and displays the armed message. The red ARMED indicator lights.

3.You may leave through an entry/exit door during the exit delay period without causing an alarm.

After the exit delay expires, the system arms and sounds an alarm immediately if a protected window or non-entry/exit door is opened, or if any movement is detected inside your premises.

You may re-enter through an entry/exit door, but must disarm the system within the entry delay period to avoid an alarm.

NOTE ON ARMING “AWAY“

If the system is armed AWAY and no one has passed through an Entry/Exit zone, the system will automatically arm in the STAY mode, if so programmed. Ask if this feature is present in your system and,

if so, check here:

THE AWAY KEY ARMS THE ENTIRE SYSTEM (INTERIOR AND PERIMETER), BUT ALLOWS USE OF THE ENTRY/EXIT DOOR.

TYPICAL DISPLAYS "ARMED AWAY"

ARMED *** AWAY ***

YOU MAY EXIT NOW

The message “you may exit now” changes to ALL SECURE when the exit delay expires.

ALPHA

AWAY AC

FIXED-WORD

– 18 –

Image 18
Contents First Alert Table of Contents System Overview Fire Protection Chime Feature System OverviewAbout the Keypads Alpha KeypadsFixed-Word Keypads BAT AlarmChime CheckStyle a Display Style B Display Functions of the Keypad Typical Alpha Keypad Security Codes General To Assign, Change, or Delete User CodesTo Change Your Master Code Security CodesDuress Code Phone Voice ModuleENTRY/EXIT Delays Exit Delay Seconds Entry Delay NoUsing the Ready Key Checking for Open ZonesTo Display Open ZONES, Press Using Bypass Key Bypassing Protection ZonesTo Bypass Zones Bypassing Protection Zones Quick BypassUsing Stay Key Arming Perimeter onlyStay Using Instant KeyUsing Away Key Use this key when no one will be staying insideArming ALL Protection Maximum KEY Using Maximum KeyAn alarm sounds immediately, when someone re-enters Away ACDisarming the System and Silencing Alarms Using OFF KeyExit Alarms Chime ModeUsing Chime Key For Manually Activating Silent AND/OR Audible Alarms Panic KeysPanic Keys Output Relay OptionsResponse to zone activity or manual entries Testing the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsCOMM. Failure Trouble ConditionsOther Trouble Displays System LO BATDisabled. Call for Service Immediately AC LossFire Alarm System if Installed 05 ACManually Initiating Fire Alarm SystemFire Alarm Press the key pair assigned for Fire emergencySmoke Detectors for Minimum Protection Steps to Safety Emergency EvacuationFunction Procedure Comments Quick Guide to System FunctionsSummary of AUDIBLE/VISUAL Notifications Alpha Display KeypadsFIXED-WORD Display Keypads Protection Zones List Protection Zone DescriptionsZone Description Owners Insurance Premium Credit Request Owners Insurance Premium Canadian Department of Communications DOC Statement AvisUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA145C specifications

The First Alert FA145C is an innovative smoke and carbon monoxide detector designed to enhance safety in residential settings. This intelligent device combines advanced technology with user-friendly features, ensuring that homeowners can protect their families from fire and toxic gas threats effectively.

At the core of the FA145C is its dual-sensor technology, which utilizes both photoelectric and ionization sensors. The photoelectric sensor excels at detecting smoldering fires, often caused by burning materials like mattresses and upholstery, while the ionization sensor is highly effective in identifying flaming fires, such as those ignited by paper or flammable liquids. This combination results in faster response times to a wider range of fire types, significantly increasing safety within the home.

The FA145C also features a built-in carbon monoxide detector, providing an added layer of protection against this odorless and colorless gas. Carbon monoxide is a byproduct of burning fossil fuels, and exposure can lead to serious health hazards. The incorporation of CO detection in one device simplifies the safety measures in a home and ensures comprehensive monitoring.

A standout feature of the First Alert FA145C is its voice alert system. This system provides clear announcements, indicating whether smoke or carbon monoxide has been detected. By minimizing confusion during emergencies, the voice alerts allow for quicker and more informed reactions, particularly in a panic-inducing situation.

The unit is equipped with a 10-year battery life, which reduces the hassle and costs associated with frequent replacements. The long-lasting battery ensures that the device remains operational for an extended period, contributing to peace of mind for homeowners. Additionally, the FA145C includes a convenient battery status indicator, alerting users when the battery is running low.

Installation is straightforward, thanks to the user-friendly design and included mounting hardware. The sleek, modern appearance of the FA145C allows it to blend seamlessly with various interior styles, making it a practical choice for any home.

Overall, the First Alert FA145C stands out as a crucial safety tool, integrating advanced sensors, voice alerts, and long battery life into a single device. This smoke and carbon monoxide detector sets a high standard for residential safety, offering homeowners both reassurance and protection against potential hazards.