First Alert FA145C user manual Typical Alpha Keypad

Page 9

1

15

**** DISARMED ****

READY TO ARM

17

3

14

2

5

16

SHOWN WIH

SHOWN WITH

FLIP-DOWN

FLIP-DOWN

KEY COVER

ARMED

READY

First Alert

AB

CD

OFF AWAY STAY

1 2 3

MAXIMUM TEST BYPASS

4 5 6

INSTANT CODE CHIME

7 8 9

READY

* 0 #

Professional

4

6

7

10

9

KEYREMOVEDCOVER REMOVED

8

11

13

12

TYPICAL ALPHA KEYPAD

Fixed-Word Keypads are functionally similar, except for screen displays (see page 6).

IMPORTANT!: When entering codes and commands, sequential key depressions must be made within 2 seconds of one another. If 2 seconds elapses without a key depression, the entry is aborted and must be repeated from its beginning.

– 9 –

Image 9
Contents First Alert Table of Contents System Overview System Overview Fire Protection Chime FeatureAbout the Keypads Alpha KeypadsFixed-Word Keypads Chime AlarmBAT CheckStyle a Display Style B Display Functions of the Keypad Typical Alpha Keypad General To Assign, Change, or Delete User Codes Security CodesDuress Code Security CodesTo Change Your Master Code Phone Voice ModuleExit Delay Seconds Entry Delay No ENTRY/EXIT DelaysUsing the Ready Key Checking for Open ZonesTo Display Open ZONES, Press Using Bypass Key Bypassing Protection ZonesTo Bypass Zones Quick Bypass Bypassing Protection ZonesUsing Stay Key Arming Perimeter onlyStay Instant Key UsingUsing Away Key Use this key when no one will be staying insideArming ALL Protection An alarm sounds immediately, when someone re-enters Using Maximum KeyMaximum KEY Away ACUsing OFF Key Disarming the System and Silencing AlarmsExit Alarms Chime ModeUsing Chime Key Panic Keys For Manually Activating Silent AND/OR Audible AlarmsPanic Keys Output Relay OptionsResponse to zone activity or manual entries Using Test Key Testing the SystemPaging Feature Testing the SystemTrouble Conditions Check and Battery DisplaysOther Trouble Displays Trouble ConditionsCOMM. Failure System LO BATAC Loss Disabled. Call for Service Immediately05 AC Fire Alarm System if InstalledFire Alarm Fire Alarm SystemManually Initiating Press the key pair assigned for Fire emergencySmoke Detectors for Minimum Protection Emergency Evacuation Steps to SafetyQuick Guide to System Functions Function Procedure CommentsAlpha Display Keypads Summary of AUDIBLE/VISUAL NotificationsFIXED-WORD Display Keypads Protection Zones List Protection Zone DescriptionsZone Description Owners Insurance Premium Credit Request Owners Insurance Premium Avis Canadian Department of Communications DOC StatementUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA145C specifications

The First Alert FA145C is an innovative smoke and carbon monoxide detector designed to enhance safety in residential settings. This intelligent device combines advanced technology with user-friendly features, ensuring that homeowners can protect their families from fire and toxic gas threats effectively.

At the core of the FA145C is its dual-sensor technology, which utilizes both photoelectric and ionization sensors. The photoelectric sensor excels at detecting smoldering fires, often caused by burning materials like mattresses and upholstery, while the ionization sensor is highly effective in identifying flaming fires, such as those ignited by paper or flammable liquids. This combination results in faster response times to a wider range of fire types, significantly increasing safety within the home.

The FA145C also features a built-in carbon monoxide detector, providing an added layer of protection against this odorless and colorless gas. Carbon monoxide is a byproduct of burning fossil fuels, and exposure can lead to serious health hazards. The incorporation of CO detection in one device simplifies the safety measures in a home and ensures comprehensive monitoring.

A standout feature of the First Alert FA145C is its voice alert system. This system provides clear announcements, indicating whether smoke or carbon monoxide has been detected. By minimizing confusion during emergencies, the voice alerts allow for quicker and more informed reactions, particularly in a panic-inducing situation.

The unit is equipped with a 10-year battery life, which reduces the hassle and costs associated with frequent replacements. The long-lasting battery ensures that the device remains operational for an extended period, contributing to peace of mind for homeowners. Additionally, the FA145C includes a convenient battery status indicator, alerting users when the battery is running low.

Installation is straightforward, thanks to the user-friendly design and included mounting hardware. The sleek, modern appearance of the FA145C allows it to blend seamlessly with various interior styles, making it a practical choice for any home.

Overall, the First Alert FA145C stands out as a crucial safety tool, integrating advanced sensors, voice alerts, and long battery life into a single device. This smoke and carbon monoxide detector sets a high standard for residential safety, offering homeowners both reassurance and protection against potential hazards.