Operator’s Guide
Keypad Options
KPD KPD
OPT DIAG STOP
CURRENT KEYPAD ADDRESS: 01
KEYPAD MODE:
*SUP UNSUP
DEFAULT KEYPAD MSG:
Arm panic keys:
PN em F1
Keypad Options (KPD OPT)
To program keypad options, press the left Select key under KPD OPT. The display changes to CURRENT KEYPAD ADDRESS: # #.
Current Keypad Address
The Membrane Keypad must be set to keypad address 01. This is the default setting and should not be changed.
Keypad Mode
The Membrane Keypad can be set for either Supervised or Unsupervised operation. It is recommended the setting be left at the default Supervised setting.
Default Keypad Message
Press COMMAND to scroll past this option. The
Arm Panic Keys
The Panic Keys should be disabled. They cannot be used on the
Activate zone 2
Shunt: no yes
Activate zone 3
Exit: no yes
4 digit entry
Cards: no yes
All?: No yes
Delay: 2
Zone 2 Shunt
Leave this option set to NO.
Zone 3 Exit
Leave this option set to NO.
Entry Cards
Leave this option set to NO.
All?
Leave this option set to NO.
Accessing Keypad Diagnostics
KPD | KPD | Keypad Diagnostics (KPD DIAG) |
OPT | DIAG STOP | The Keypad Diagnostic option allows you to check the display segments, check the |
|
| keyboard backlighting, and test individual keys. |
|
| |
|
| Press the Select key under KPD DIAG. The keypad lights all display segments and |
|
| illuminates the keyboard in green. A few seconds later the keypad turns the display off |
|
| and illuminates the keyboard in red. The keypad then alternates between these two |
|
| states for approximately two minutes. Press COMMAND at any time to continue. |
| Test Individual Keys | |
Press key to | ||
Test |
| The display changes to PRESS KEY TO TEST. This option allows you to test each key on |
|
| the keyboard to ensure it is operating properly. Press and hold each key for about two |
|
| |
|
| seconds. The key number being held appears in the display. Verify the correct number |
|
| displays before testing the next key. |
Exiting the Installer Options
When done, press the COMMAND key once to return to the Installer Options screen. Press the Select key under STOP to exit the Installer Options function.