DSCover Satellite Products PC1555MX Third System Option Code Default Off Section Page #

Page 36

[015] Third System Option Code

 

 

 

Default

 

 

Option

ON

Off

Section Page #

ON

I

I

1

Fire Keys Enabled

Fire Keys Disabled

5.16

23

OFF

I

I

2

Panic Keys Audible (Bell / Beeps)

Panic Keys Silent

5.16

23

OFF

I

I

3

Quick Exit Enabled

Quick Exit Disabled

3.4

8

ON*

I

I

4

Quick Arming Enabled

Quick Arming Dis. / Function keys Req. Code 3.4

8

OFF

I

I

5

Code Required For Bypassing

No Code Required

3.4

8

OFF

I

I

6

Master Code Not Changeable

Master Code Changeable

5.1

15

ON

I

I

7

TLM Enabled

TLM Disabled

5.12

22

OFF

I

I

8

TLM Audible (Bell) When Armed

TLM Trouble Beeps When Armed

5.12

22

* When using a PC5132 version 2.1 or older with WLS909 Wireless Keys, option [4] must be ON for the Arm button to work.

 

[016] Fourth System Option Code

 

 

 

Default

 

 

Option

ON

Off

Section Page #

ON

I

I

1

AC Trouble Displayed

AC Trouble Not Displayed

3.4

8

OFF

I

I

2

Trouble Light Flashes if AC Fails

Trouble Light Does Not Follow AC Status

3.4

8

OFF

I

I

3

Blank Keypad When Not Used

Keypad Active Always

5.22

25

OFF

I

I

4

Code Required to Remove Kypd BlankingNo Code Required

5.22

25

ON

I

I

5

Keypad Backlighting is enabled

Keypad Backlighting is disabled

5.23

25

OFF

I

I

6

Power Save Mode enabled

Power Save Mode disabled

5.22

25

OFF

I

I

7

Bypass Status Displayed While Armed

Bypass Status Not Displayed While Armed

5.17

23

OFF

I

I

8

Keypad Tampers enabled

Keypad Tampers disabled

5.25

25

[017] Fifth System Option Code

 

 

 

Default

 

 

Option

ON

Off

Section Page #

ON

I

I

1

WLS Key Does Not Use Access Codes*

WLS Key Uses Access Codes

5.17

23

OFF

I

I

2-7

For Future Use

 

 

 

OFF

I

I

8

Squawk on Away Arming/Disarming OnlyBell Squawk on all Arming/Disarming

5.17

23

*This option must be enabled when using a PC5132 v2.1 or earlier.

[020]Keypad Zone Assignments (Section 2.13 “Keypad Zones” on page 7)

NOTE: Only one keypad may be assigned to a zone.

Default

00

I

I

I

00

I

I

I

00

I

I

I

00

I

I

I

00

I

I

I

00

I

I

I

00

I

I

I

00

I

I

I

Keypad (slot 1) Zone

Valid entries are zones 01-32

Keypad (slot 2) Zone

Valid entries are zones 01-32

Keypad (slot 3) Zone

Valid entries are zones 01-32

Keypad (slot 4) Zone

Valid entries are zones 01-32

Keypad (slot 5) Zone

Valid entries are zones 01-32

Keypad (slot 6) Zone

Valid entries are zones 01-32

Keypad (slot 7) Zone

Valid entries are zones 01-32

Keypad (slot 8) Zone

Valid entries are zones 01-32

[030]Zone Loop Response Options

Default

 

 

Option

ON

Off

Section Page #

OFF

I

I

1

Zone 1 is Fast Loop Response

Zone 1 is Normal Loop Response

5.24

25

OFF

I

I

2

Zone 2 is Fast Loop Response

Zone 2 is Normal Loop Response

5.24

25

OFF

I

I

3

Zone 3 is Fast Loop Response

Zone 3 is Normal Loop Response

5.24

25

OFF

I

I

4

Zone 4 is Fast Loop Response

Zone 4 is Normal Loop Response

5.24

25

OFF

I

I

5

Zone 5 is Fast Loop Response

Zone 5 is Normal Loop Response

5.24

25

OFF

I

I

6

Zone 6 is Fast Loop Response

Zone 6 is Normal Loop Response

5.24

25

OFF

I

I

7-8

For future use

 

 

 

WWW.DIYALARMFORUM.COM

32

Image 36
Contents Installation Manual See Back Cover for New FeaturesLimited Warranty Table of Contents PC1555MX Wiring Diagram Specifications System IntroductionAdditional Devices Out of the BoxInstallation Steps Getting StartedTerminal Descriptions Wire Routing for Power & Non-Power Limited Keybus Operation & WiringExample of Keybus Wiring Zone Input Terminals Z1 to Z6Current Ratings Modules & Accessories Zone WiringKeypad Assignment SupervisionFire Zone Wiring 11 24-Hr Auxiliary Input Wiring PGM2Links Zone Wiring Keypad Zones Links Supervision 24 Hour SupervisoryLinks Answer Assigning Keypad ZonesKeypad Commands CommandsArming and Disarming Auto Bypass Stay ArmingAlarm Memory Trouble DisplayTo view trouble conditions from an LED keypad Door Chime On/OffMaster Code Access Code Supervisor Codes Access Code 41Access Code Attributes Viewing the Event Buffer from an LCD KeypadFunction Keys Features Available for the LCD5500Z How to Program Installer’s ProgrammingProgramming Decimal Data Programming HEX DataPage Program Descriptions Programming Security CodesZone Programming Zone Attributes Communicator Account Numbers Assigning Keypad ZonesCommunicator Dialing Communicator Telephone NumbersOpenings/Closings by Wireless Key AC Failure Trouble Alarm CodeZone Restorals Closings Arming CodesPulse Formats Contact IDAdditional Notes on Contact ID Pager FormatDownloading PGM Output OptionsKeypad Buzzer Follower Mode TLM and AlarmArmed Status Ready To ArmTelephone Line Monitor TLM BellTransmission Delay Test TransmissionFire, Auxiliary and Panic Keys Arming/Disarming OptionsEntry/Exit Delay Options Swinger ShutdownEvent Buffer Keypad Lockout OptionsKeypad Blanking Keypad BacklightingLoop Response Keypad TampersResetting Factory Defaults Installer’s LockoutWalk Test Installer Additional System ModulesProgramming Worksheets For the RecordModule Name Description Location Keypads Keypad Type LocationSerial Number Wireless Zone Programming SummarySystem Zone Label Zone Attributes Type Default Keypad ProgrammingBasic Programming Function Key OptionsSystem Times Default Valid entries Programmable Output OptionsFirst System Option Code Default Off Section Page # Second System Option Code Default Off SectionProgram PGM Option Attributes in sections 143 Program PGM Option Attributes in sections 151Third System Option Code Default Off Section Page # Fourth System Option Code Default Off Section Page #Fifth System Option Code Default Off Section Page # Zone Loop Response Options Default Off Section Page #Zone Attribute Defaults Y = Option on N = Option OFF Advanced System ProgrammingZone Type Section Zone # TypePGM Attribute Defaults Y = Attribute on N = Attribute OFF PGM OptionMain Board PC5208PC5204 Communicator Programming Miscellaneous Closing Arming Reporting Codes Default Option Miscellaneous Opening Disarming Reporting Codes01 20 BPS, 1400 HZ handshake 02 20 BPS, 2300 HZ handshake PagerCommunication Variables Default Section First Communicator Option Code DefaultSecond Communicator Option Code Default Default FfffDefault Ffffff I I I I I Default Option OffSpecial Installer Functions International ProgrammingModule Programming Appendix a Reporting Codes SIA Format Level 2 HardcodedContact ID Zone Alarm/Restoral Event Codes as per Ademco SIA Format Automatic Zone Alarm/Restoral CodesAppendix B Programming LCD Keypads Second User Display Mask Default Option Third User Display Mask Default OptionKey Options Default Fourth User Display Mask Default OptionUL Listed Commercial and Residential Installations Fifth User Display Mask Default OptionSixth User Display Mask Default Option Reset LCD Eeprom to Factory Defaults Ascii CharactersImportant Information PC1555MX Module Compatibility Changes for PC1555MX

PC1555MX specifications

The DSCover Satellite Products PC1555MX is an advanced satellite communication device designed to meet the demands of both commercial and industrial sectors. Its high-performance capabilities are complemented by a robust design, making it an excellent choice for users who require reliable connectivity in remote or challenging environments.

At the heart of the PC1555MX is its cutting-edge satellite technology, which enables seamless communication regardless of geographical constraints. The device operates on multiple frequency bands, enhancing its versatility and ensuring optimal performance in diverse conditions. This multi-band capability allows for greater flexibility in communication, accommodating various applications from data transmission to voice calls.

One of the standout features of the PC1555MX is its impressive data transfer speeds. With advancements in modulation techniques, users can enjoy fast and efficient data upload and download rates. This makes the device particularly suitable for applications that require real-time data processing, such as telemetry, remote monitoring, and emergency response communications.

The PC1555MX also incorporates advanced encryption protocols to ensure data security during transmission. This is especially crucial for industries such as defense, security, and finance, where sensitive information must be safeguarded against potential breaches. Users can have peace of mind knowing that their communications are protected by state-of-the-art security measures.

In addition to its communication capabilities, the PC1555MX is designed with user-friendly operation in mind. Its intuitive interface allows for easy navigation and control, making it accessible even to those with limited technical expertise. Furthermore, the device is equipped with a comprehensive alert system that notifies users of any connectivity issues or performance deviations, ensuring that they remain informed and can take swift action if necessary.

Durability is another key characteristic of the DSCover PC1555MX. Built to withstand harsh environmental conditions, it features a rugged exterior that is both weather-resistant and shockproof. This level of durability makes the device suitable for deployment in various settings, from outdoor expeditions to industrial sites.

Overall, the DSCover Satellite Products PC1555MX stands out as a premier choice for satellite communication. With its advanced features, robust design, and commitment to security and performance, it effectively meets the needs of users in an increasingly connected world. Whether for business operations or emergency services, the PC1555MX ensures that critical communications remain uninterrupted.