O 'FTNOOD

rE"T,,,,L

$

f,l,

 

_._

VENT TO OUTDOORS

DRAFTHOOD

___R

CHIMNEY

Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.

Chemical vapor corrosion of the flue and vent system may occur

if air for combustion contains certain chemical vapors. Spray

can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and

sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

FIGURE 17.

The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward at least 1/4 inch per linear foot (21 mm per meter).

See Figure 18.

CHIMNEY

FIGURE 18.

All vent gases must be completely vented to the outdoors of the

structure (dwelling). Install only the draft hood provided with the new water heater and no other draft hood.

Vent pipes must be secured at each joint with sheet metal screws.

There must be a minimum of 6 inches (153 mm) clearance

between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and

combustible material with mortar mix, cement, or other

noncombustible substance. For other than single wall, follow

vent pipe manufacturer's clearance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement.

Breathing Hazard - Carbon Monoxide Gas

. Flue gases may escape if vent pipe is not connected.

Do not store corrosive chemicals in vicinity of water heater.

Chemical corrosion of flue and vent system can cause serious injury or death.

Contact a qualified installer or service agency.

Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual.

Failure to have required clearances between vent piping and

combustible material will result in a fire hazard.

Gas Piping

Fire and Explosion Hazard

Do not use water heater with any gas other than the gas shown on the rating plate.

Excessive pressure to gas control valve can cause serious

injury or death.

Turn off gas lines during installation.

Contact qualified installer or service agency.

Make

sure the

gas

supplied

is

the

same

 

type

listed

on

the model

rating

plate.

The

inlet

gas

pressure

must

not

exceed

14 inch water

column

(3.5kPa)

for

natural

and

propane

gas

(L.R)

gas.

The

minimum inlet gas pressure listed on the rating plate

is for

the

purpose

of input

adjustment.

If the

gas

control valve is

subjected

to

pressures

exceeding

1/2

 

pound

per

square

inch

(3.5kPa),

the

damage

to the

gas

control

valve

could

result

in a

fire or explosion from leaking gas.

If the main gas line shutoff serving all gas appliances is used,

also turn "OFF" the gas at each appliance. Leave all gas

appliances shut "OFF" until the water heater installation is complete.

A gas line of sufficient size must be run to the water heater. Consult the current edition of National Fuel Gas Code ANSI

Z223.1/NFPA 54 and your gas supplier concerning pipe size.

There must be:

A readily accessible manual shut off valve in the gas supply line serving the water heater, and

A drip leg (sediment trap) ahead of the gas control valve to

help prevent dirt and foreign materials from entering the gas control valve.

A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse off soapy solution and wipe dry.

The minimum inlet gas pressure shown on the rating plate is that which will permit firing at the rated input.

16

Image 16
Contents For Your Safety Safety instructions , installationOperation Care and Maintenance Troubleshooting Parts List Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.AImportant Definitions Improper installation and use may result Property damage Fire or Explosion HazardFire Hazard Breathing Hazard Carbon Monoxide GasCombustionAirandVentilationAppliances 11-1212-13 13-14ThankYouforpurchasingKenmorewaterheaterProperly ContractorsAdditional Tools Needed When Sweat Soldering Materials NeededSqueeze Tube USE for Water and GASPilot Burner Closed Water SystemPilot Thermopile Tubing TCO Removing the Old Water Heater Facts to Consider About Location MIN Insulation BlanketsFire or Explosion Hazard Breathing Hazard Carbon Monoxide GasAllair from Inside Buildings Toxic Chemical Hazard Water PipingRgure Notbeintroducedintothissystem LookatthetopofthewaterheaterThecoldwaterinletisProperty Damage Hazard PiPE INSULATiON Flue PiPE×plosion Hazard Temperatu re=Pressu re Relief ValveWater Damage Hazard Property Damage Hazard VentingYo outdoors RET,,,,L Gas PipingFire and Explosion Hazard Drafthood ChimneySediment Traps LINIONLACKPiPEIf you cannot reach your gas suppltar,call the fire Rnanual before Changing TemperatureScald injury. Consult Instruction Thermostat Temperature RegulationGenerator Tank Sediment Cleaning Vent System InspectionTemperature=Pressure Relief Valve Operation TEMPERATURE-PRESSUREHousekeeping DrainingCLOSEthecoldwaterinletvalvetothewaterheater Drain Valve Washer ReplacementOPENanearbyhotwaterfaucetandleaveopentoallowfor draining Thermal Expansion Tank Expansion Tank SizingStrange Sounds Draft Hood OperationMakenecessaryairsupplychangestocorrect Operational ConditionsOperational Conditions Leakage Checkpoints Fortheseinstructions, please see Figure Locking TAB Tank Thermopile Sensor Torx GAS Valve BackplateScrew Gas control valve or tank sensor failure Tllllil 153.334530150Ga,on l LIST, not a Packing ListPage 12YEARLIMITED Warranty on Water Heater MY-HOME

334, 530 specifications

The Kenmore 334,530 is a well-regarded appliance in the realm of portable air conditioning units, offering users an efficient cooling solution for both homes and office spaces. Known for its reliability and performance, this model blends advanced technology with user-friendly features to create a cooling experience that meets diverse needs.

One of the standout characteristics of the Kenmore 334,530 is its cooling capacity, rated at 14,000 BTU. This makes it suitable for medium to large-sized rooms, effectively cooling spaces up to 600 square feet. Users can expect rapid temperature drops, making it ideal for sweltering summer days when immediate relief is needed.

The unit features a sleek design that allows for easy portability. Equipped with rolling casters, the Kenmore 334,530 can be effortlessly moved from room to room, providing flexibility based on where cooling is needed most. The convenient window installation kit simplifies the setup process, allowing for a straightforward installation without the need for professional assistance.

Energy efficiency is another key highlight of the Kenmore 334,530. With an impressive Energy Efficiency Ratio (EER), this air conditioner is designed to minimize electricity consumption while maintaining powerful cooling performance. Users can stay cool without worrying excessively about their energy bills.

Additionally, the Kenmore 334,530 is equipped with a programmable thermostat and remote control, allowing users to customize their cooling experience. The programmable timer can be set to operate at specific times, ensuring the room is cool when needed while saving energy when it isn't. The user-friendly interface and digital display make adjustments quick and intuitive.

The unit also features multiple fan speeds and cooling modes, including a dehumidifying option that removes excess moisture from the air. This capability not only enhances comfort but contributes to a healthier indoor environment by preventing mold and mildew growth.

In terms of maintenance, the Kenmore 334,530 includes an easy-to-clean washable filter that captures dust and allergens, promoting cleaner air circulation. This filter is designed to be simple to access and maintain, ensuring ongoing efficiency and performance.

Overall, the Kenmore 334,530 stands out in the portable air conditioning market, offering a combination of power, efficiency, and convenience. Its thoughtful features and advanced technology make it an excellent choice for anyone seeking reliable cooling solutions in various settings.