VENTILATION LOUVERS

OUTLET

HEATER

"FURNACE

iNLET AiR DUCT

{ENDS 1'OR 30 cm

ABOVE FLOOR)

FIGURE 12.

When communicating with the outdoors through horizontal ducts, each opening shall have a minimum free area of 1 square inch per 2,000 BTU per hour (11 cm2/kW) of total

input rating of all equipment in the enclosure. See Figure 13.

When ducts are used, they shall be of the same cross- sectional area as the free area of the openings to which they connect. The minimum short side dimension of rectangular

air ducts shall not be less than 3 inches (76.2 mm). See Figure 13.

_i__ a_

CHIMNEY OR GAS VENT

 

 

 

__W_

FURNA

II

_

OUTLET AIR DUCT

 

 

 

Water Piping

Water temperature over 125°F (52°C) can cause severe burns

instantly resulting in severe injury or death.

Children, elderly, and the physically or mentally disabled are at highest riskfor scald injury.

Feel water before bathing or showering.

Temperature limiting valves are available.

Read instruction manual for safe temperature setting.

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated

to a temperature which will satisfy space heating, clothes

washing, dish washing, cleaning and other sanitizing needs

can scald and permanently injure you upon contact. Some

people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or

physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local

code or state law requiring a certain temperature water at the

hot water tap, then you must take special precautions. In

addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a *mixing valve, shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. See Figure 14. Valves for reducing

point of use temperature by mixing cold and hot water are also

available. Follow manufacturer's instructions for installation of

the valves. Before changing the factory setting on the

thermostat, read the Temperature Regulation section in this manual.

HOT WATER

_

COLD WATER

OUTLET

]

IN__LET

FIGURE 13.

Louvers and Grilles: In calculating free area, consideration shall be given to the blocking effect of louvers, grilles or

screens protecting openings. Screens used shall not be smaller than 1/4 inch (6.4 mm) mesh. If the free area through

a design of louver or grille is known, it should be used in

calculating

the

size

opening

required

to provide

the

free

area

specified.

If the

design

and

free

area

is not known,

it may be

assumed that wood

louvers

will be

20-25

percent

free

area

and metal

louvers

and

grilles

will have

60-75

percent

free

area. Louvers and grilles shall be fixed in the open position

or interlocked with the equipment so that they are opened

automatically during equipment operation.

Special Conditions Created by Mechanical Exhausting or

Fireplaces: operation of exhaust fans, ventilation systems, clothes dryers or fireplaces may create conditions requiring

special attention to avoid unsatisfactory operation of installed gas utilization equipment.

TEMPERE[_o

WATER OUTLET

LD WATER

ERb. T'WA%iNLET ON.EATER

*MIXINGHOT WATER

VALVEOUTLET ON WATER HEATER

RGURE 14,

Toxic Chemical Hazard

• Do not connect to non-potable water system.

12

Image 12
Contents For Your Safety Safety instructions , installationOperation Care and Maintenance Troubleshooting Parts List Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.AImportant Definitions Improper installation and use may result Property damage Fire or Explosion HazardFire Hazard Breathing Hazard Carbon Monoxide GasCombustionAirandVentilationAppliances 11-1212-13 13-14ThankYouforpurchasingKenmorewaterheaterProperly ContractorsAdditional Tools Needed When Sweat Soldering Materials NeededSqueeze Tube USE for Water and GASClosed Water System Pilot BurnerPilot Thermopile Tubing TCO Removing the Old Water Heater Facts to Consider About Location MIN Insulation BlanketsFire or Explosion Hazard Breathing Hazard Carbon Monoxide GasAllair from Inside Buildings Water Piping Toxic Chemical HazardRgure Notbeintroducedintothissystem LookatthetopofthewaterheaterThecoldwaterinletisProperty Damage Hazard PiPE INSULATiON Flue PiPETemperatu re=Pressu re Relief Valve ×plosion HazardWater Damage Hazard Venting Property Damage HazardYo outdoors RET,,,,L Gas PipingFire and Explosion Hazard Drafthood ChimneySediment Traps LINIONLACKPiPERnanual before Changing Temperature If you cannot reach your gas suppltar,call the fireScald injury. Consult Instruction Temperature Regulation ThermostatGenerator Tank Sediment Cleaning Vent System InspectionTemperature=Pressure Relief Valve Operation TEMPERATURE-PRESSUREHousekeeping DrainingDrain Valve Washer Replacement CLOSEthecoldwaterinletvalvetothewaterheaterOPENanearbyhotwaterfaucetandleaveopentoallowfor draining Thermal Expansion Tank Expansion Tank SizingStrange Sounds Draft Hood OperationMakenecessaryairsupplychangestocorrect Operational ConditionsOperational Conditions Leakage Checkpoints Fortheseinstructions, please see Figure GAS Valve Backplate Locking TAB Tank Thermopile Sensor TorxScrew Gas control valve or tank sensor failure Tllllil 153.334530150Ga,on l LIST, not a Packing ListPage 12YEARLIMITED Warranty on Water Heater MY-HOME

334, 530 specifications

The Kenmore 334,530 is a well-regarded appliance in the realm of portable air conditioning units, offering users an efficient cooling solution for both homes and office spaces. Known for its reliability and performance, this model blends advanced technology with user-friendly features to create a cooling experience that meets diverse needs.

One of the standout characteristics of the Kenmore 334,530 is its cooling capacity, rated at 14,000 BTU. This makes it suitable for medium to large-sized rooms, effectively cooling spaces up to 600 square feet. Users can expect rapid temperature drops, making it ideal for sweltering summer days when immediate relief is needed.

The unit features a sleek design that allows for easy portability. Equipped with rolling casters, the Kenmore 334,530 can be effortlessly moved from room to room, providing flexibility based on where cooling is needed most. The convenient window installation kit simplifies the setup process, allowing for a straightforward installation without the need for professional assistance.

Energy efficiency is another key highlight of the Kenmore 334,530. With an impressive Energy Efficiency Ratio (EER), this air conditioner is designed to minimize electricity consumption while maintaining powerful cooling performance. Users can stay cool without worrying excessively about their energy bills.

Additionally, the Kenmore 334,530 is equipped with a programmable thermostat and remote control, allowing users to customize their cooling experience. The programmable timer can be set to operate at specific times, ensuring the room is cool when needed while saving energy when it isn't. The user-friendly interface and digital display make adjustments quick and intuitive.

The unit also features multiple fan speeds and cooling modes, including a dehumidifying option that removes excess moisture from the air. This capability not only enhances comfort but contributes to a healthier indoor environment by preventing mold and mildew growth.

In terms of maintenance, the Kenmore 334,530 includes an easy-to-clean washable filter that captures dust and allergens, promoting cleaner air circulation. This filter is designed to be simple to access and maintain, ensuring ongoing efficiency and performance.

Overall, the Kenmore 334,530 stands out in the portable air conditioning market, offering a combination of power, efficiency, and convenience. Its thoughtful features and advanced technology make it an excellent choice for anyone seeking reliable cooling solutions in various settings.