Kenmore 153.33453, 153.33443 Temperature-Pressure Relief Valve, Valve and Pipe Insulation

Page 14

T & P Valve and Pipe Insulation

Remove insulation for T & P valve and pipe connections from carton.

FIGURE 15A.

Fit pipe insulation over the incoming cold water line and the hot water line. Make sure that the insulation is against the top cover of the heater.

Fit T & P valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T & P valve.

Secure all insulation using tape.

Temperature-Pressure Relief Valve

For safe operation of the water heater, the relief valve must not be removed from its designated opening nor plugged.

The temperature-pressure relief valve must be installed directly into the fi tting of the water heater designed for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches (153 mm) above, or at any distance below the structural fl oor, see Figure 16. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet (9.14 m), or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6 inch air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water fl ow may cause property damage.

FIGURE 16.

This heater is provided with a properly certifi ed combination temperature - pressure relief valve by the manufacturer.

The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment as meeting the requirements for Relief Valves for Hot Water Supply Systems, ANSI Z21.22 and the code requirements of ASME.

If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certifi ed as indicated in the above paragraph.

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 psi = 1,035 kPa) and a discharge capacity not less than the water heater input rate as shown on the model rating plate.

The Discharge Pipe:

Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Shall not be plugged or blocked.

Shall be of material listed for hot water distribution.

Shall be installed so as to allow complete drainage of both

14

Image 14
Contents HydroSense Gas Water Heater Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.ASafe INSTALLATION, USE and Service Important DefinitionsSafety Precautions Table of Contents Product Specifications Customer ResponsibilitiesBasic Tools Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Typical Installation GET to Know Your Water Heater GAS ModelsInstallation Instructions Removing the Old Water HeaterFacts to Consider About the Location Insulation Blankets ALL AIR from Inside Buildings Water Piping Hotter Water can ScaldInstallation Completed Using Installation KIT Temperature-Pressure Relief Valve Valve and Pipe InsulationFilling the Water Heater VentingGas Piping GAS Piping with Flexible Connector Sediment TrapsOperating Instructions Temperature Regulation Temperature Time to Produce 2nd & 3rdBurner Cleaning Service and AdjustmentTank Sediment Cleaning Vent System InspectionAnode Rod Inspection Temperature-Pressure Relief Valve OperationHousekeeping DrainingDrain Valve Washer Replacement ServiceStart Up Conditions Thermal ExpansionOperational Conditions CondensationLeakage Checkpoints Service Instructions for GAS Control Valve Assembly Removing Gas Valve AssemblyGAS Valve Backplate GAS Valve Nipple Troubleshooting Guide OFFTroubleshooting Guide Parts Order List Hydrosense GAS Water HeaterPage MY-HOME