SERVICE AND ADJUSTMENT

Tank (Sediment) Cleaning

Sediment build-up on the tank bottom may create varying amount of noise, and if left in the tank will cause permanent tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. In these cases Mag-Erad (part no. 23600) can be used to help remove the sediment deposits. This may be ordered from the Sears Service Center. For ordering, refer to the Parts Order List section.

Vent System Inspection

Flue gases may escape if vent pipe is not connected.

Be alert for obstructed, sooted or deteriorated vent system to avoid serious injury or death.

Do not store corrosive chemicals in vicinity of water heater.

Chemical corrosion of fl ue and vent system can cause serious injury or death

At least once a year a visual inspection should be made of the venting system. You should look for:

Obstructions which could cause improper venting. The combustion and ventilation air fl ow must not be obstructed.

Damage or deterioration which could cause improper venting or leakage of combustion products.

Rusted fl akes around top of water heater.

Be sure the vent piping is properly connected to prevent escape of dangerous fl ue gasses which could cause deadly asphyxiation.

Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.

Chemical vapor corrosion of the fl ue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

If when inspecting the vent system you find sooting or deterioration, something is wrong. Call the local gas supplier to correct the problem and clean or replace the fl ue and venting before resuming operation of the water heater.

Burner Inspection

Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a

ooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Contact a Sears Service Center to replace a fl ooded water heater. Do not attempt to repair the unit! It must be replaced!

At least once a year a visual inspection should be made of the main burner and pilot burner. See Figure 23.

You should check for sooting. Soot is not normal and will impair proper combustion.

Soot build-up indicates a problem that requires correction before further use. Turn “OFF” gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fi re causing death, serious injury, or property damage.

FIGURE 23.

Burner Cleaning

In the event your burner needs cleaning, following these instructions:

If inspection of the burner shows that cleaning is required, turn the gas control knob counter-clockwise ( ) to the “OFF” position, depressing slightly.

The burner needs to be removed for cleaning. Call the Sears Service Center to remove and clean the burner and correct the problem that required the burner to be cleaned.

20

Image 20
Contents HydroSense Gas Water Heater Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.ASafe INSTALLATION, USE and Service Important DefinitionsSafety Precautions Table of Contents Product Specifications Customer ResponsibilitiesBasic Tools Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Typical Installation GET to Know Your Water Heater GAS ModelsInstallation Instructions Removing the Old Water HeaterFacts to Consider About the Location Insulation Blankets ALL AIR from Inside Buildings Water Piping Hotter Water can ScaldInstallation Completed Using Installation KIT Temperature-Pressure Relief Valve Valve and Pipe InsulationFilling the Water Heater VentingGas Piping GAS Piping with Flexible Connector Sediment TrapsOperating Instructions Temperature Regulation Temperature Time to Produce 2nd & 3rdService and Adjustment Tank Sediment CleaningBurner Cleaning Vent System InspectionTemperature-Pressure Relief Valve Operation HousekeepingAnode Rod Inspection DrainingDrain Valve Washer Replacement ServiceStart Up Conditions Thermal ExpansionOperational Conditions CondensationLeakage Checkpoints Service Instructions for GAS Control Valve Assembly Removing Gas Valve AssemblyGAS Valve Backplate GAS Valve Nipple Troubleshooting Guide OFFTroubleshooting Guide Parts Order List Hydrosense GAS Water HeaterPage MY-HOME