Kenmore 153.335863, 153.335846 Installation Instructions contd, Venting, Wiring Diagram

Page 16

Installation Instructions (cont'd)

USE WITHOUT POWER CORD (cont'd)

3.A standard _" conduit opening has been made in the water heater junction box for the conduit connection.

4.Use wire nuts and connect the power supply wiring to the wires inside the water heater's junction box.

5.The water heater must be electrically "grounded" by the installer. A green ground screw has been provided on the

WIRING DIAGRAM

_v

ON_F

SW;TCH

GA$

P_ESSURE

SWITCH

laOV GAS

 

 

SOLENOID

HI.UMIT

 

 

SWlTC_ N_ N O

RESW_TCH

INOICATOn LIGHT I_V

o

Venting

water heater's junction box. Connect ground wire to this location. For complete grounding details and all allowable exceptions, refer to local codes or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70.

6.Replace the wiring junction cover using the screw provided.

Ain PRE$$UnE

sWITCH

F\

_ J

 

_

 

ItL_CK

HOT

_

_

_ITE

NEuTnAc

 

...... 11I[ WXlTE....

I

[

*_v GAS SOLENOIO

AWARNINGI

To insureproperventingof this gas.firedwater heater,the cor- rect vent pipe diameter must be utilized. Any additions of other gas appliances on vent with this water heater will

[ adversey affectthe operationofthe water heater.

I

The combustion and ventilation air flow must not be obstructed.

AWARNING

]

The water heater with_stalled

must be properly

vented to a chimneywhichterminatesoutdoors.Never oper-I ate the water heater unlessit isventedto the outdoorsand has adequateair supplyto avoidrisks of improperoperation,explo-

sionor asphyxiation.

]

AWARNING

Obstructed or deterioratedventsystemsmay presenta serious

healthrisk or asphyxation.

_,WARNING

The vent pipe from the water heater must slopeupward I/4 nch per near foot.

All vent gases must be completely vented to the outdoors of the structure (dwelling).

MIN. RISE I/4"

PERFOOT

I

Failureto haverequired clearancesbetweenwater heater

_,WARNINGand

combustibe material wi resu t n a Erehazard.

16

Image 16
Contents For Your Safety Water HeaterWhat to do if YOU Smell GAS Or Operating this Water HeaterSafety Precautions DEATH, Serious Bodily INJURY, or PropertySafety Precautions Safety Precautions onAwarningj AwarningAwarning Contents Install or Operate the Water Heater Customer ResponsibilitiesAdditional Tools Needed When Sweat Soldering Materials and Basic Tools NeededRemoving the Old Water Heater Installation InstructionsWater passingouve Locating the New Water Heater While this may reduce the chancesof flammablevaporsfrom aThis warningmay result in a fire hazard Heateradjacentto the gascontrolvalvefor all clearancesInstallation Instructions ContdVenting Clearances IFigure 3aInstallation Instructions contd Venting Through Roof- ClearancesVErTm Temperature Regulationsectioninthismanual Installation Completed Using Sears Installation KITWater Piping Hotter Water can SCALDWater heatersare intendedtoTemperature-Pressure Relief Valve At the time of manufacturethis water heater was providedWiring USE with Power CordUSE Without Power Cord Filling the Water HeaterWiring Diagram Installation Instructions contdVenting Venting contd Venting Through AN Outside Wall ALL ModelsVenting System Example Installations for ALL Models Precautions Installation Showing USE of PVC, ABS or Cpvc PipeConnecting PVC Pipe Vent to Blower Venting Through a Roof ALL ModelsPVC Schedule 40 vent piping Gas Piping Sediment TrapGAS Piping with GAS Piping with ALL Black Iron Pipe to GAS ControlContd Installation ChecklistBefore Lighting the Pilot Operating Instructions Before the Water Heater will OperateBy this Water Heater For Your Safety If YOU Shell GAS LightingAwarning Before Lighting Propane L.R GAS Water AN Odorant iS Added to the GAS UsedOperating Instructions contd Whattodoif YousmellgasOperating Instructions contd Temperature RegulationSonunattendedin a bathtubor shower Service and Adjustment Tank Sediment CleaningBurner Inspection Oiling InstructionsService and Adjustment contd Gas Control Valve & Burner Assembly Replacement InformationTemperature-Pressure Relief Valve Operation DrainingService Drain Valve Washer ReplacementHousekeeping Strange Sounds Start Up ConditionsThermal Expansion Troubleshooting Guide contd Operational ConditionsCondensation SMOKE/ODOROperational Conditions contd High Temperature Shut OFF SystemWater is TOO HOT Leakage Checkpoints AcautioniTroubleshooting Guide contd Thermostat and GAS Supply Check0RE Troubleshooting Guide contdAcaution Property DamageYes Page Power Miser TM 9 Power Vent GAS Water Heaters Parts Order ListPower Miser TM 9 Power Vent GAS Water Heaters Model Numbers Parts Order List contdParts Order List Parts Order List contd Part DescriptionWarranty MY-HOMIE