Kenmore 153.335863, 153.335846 Operating Instructions, Before the Water Heater will Operate

Page 24

Operating Instructions

This water heater is equipped with an electrically operated vent- ing system and a standing pilot. For the burner to come on, the water heater thermostat must call for heat. Then the system will

begin sequencing, each section proving itself before gas is allowed to flow to the burner.

BEFORE THE WATER HEATER WILL OPERATE:

1."['he control system must be connected to a 110/120 volt power supply. The control system has an overall rating of 2 amps. The water heater must be securely and adequately grounded in accordance with local codes and with the latest

edition of the National Electrical Code ANSI/NFPA 70.

2.The ON/OFF toggle switch, located on the control box above the thermostat must be in the "ON" position for the electrical control system to operate allowing the gas portion to operate (ignite burner).

3.The pilot must be lit. See Lighting instructions on page 23

of this manual or located adjacent to the thermostat on the

water heater.

_"

4.The gas control knob located on the thermostat must be turned to the "ON" position for the gas to be able to flow.

5.The venting manual reset switch must be in the closed posi- tion. See "Venting Manual Reset Switch" in the "For Your Information Section".

6.There is a non-resettable hi-limit switch in the thermostat, which must be good (closed) for the thermostat to be oper-

ated. See "High Temperature Shut Off System" in the "For Your Information Section".

OPERATION

VENTING MANUAL RESET SWITCH

DRAFT HOOD

GASCONTROL

KNOB,

BLOWER MOTOR

AIR PRESSURE

When the thermostat calls for heat, gas is allowed to flow to a (Normally open) pressure switch closing it. An electrical circuit

is then made to the blower, turning it on. The indicator light located on the control box will come on. When the blower has

achieved sufficient venting, the air pressure switch will close and the indicator light will go oK A 120 volt circuit will be com- pleted through the venting manual reset switch and on to the

120 volt gas valve located just below the thermostat. The 120 voltgas valve will open allowing gas to flow to the burner. The standing pilot will establish a main burner flame.

/

GAS THERMOSTAT

120V GAS VALVE

j BURNER

24

Image 24
Contents For Your Safety Water HeaterWhat to do if YOU Smell GAS Or Operating this Water HeaterSafety Precautions DEATH, Serious Bodily INJURY, or PropertySafety Precautions Safety Precautions onAwarning AwarningjAwarning Contents Install or Operate the Water Heater Customer ResponsibilitiesAdditional Tools Needed When Sweat Soldering Materials and Basic Tools NeededInstallation Instructions Removing the Old Water HeaterWater passingouve Locating the New Water Heater While this may reduce the chancesof flammablevaporsfrom aThis warningmay result in a fire hazard Heateradjacentto the gascontrolvalvefor all clearancesInstallation Instructions ContdVenting Clearances IFigure 3aInstallation Instructions contd Venting Through Roof- ClearancesVErTm Temperature Regulationsectioninthismanual Installation Completed Using Sears Installation KITWater Piping Hotter Water can SCALDWater heatersare intendedtoTemperature-Pressure Relief Valve At the time of manufacturethis water heater was providedWiring USE with Power CordUSE Without Power Cord Filling the Water HeaterInstallation Instructions contd Wiring DiagramVenting Venting contd Venting Through AN Outside Wall ALL ModelsVenting System Example Installations for ALL Models Precautions Installation Showing USE of PVC, ABS or Cpvc PipeConnecting PVC Pipe Vent to Blower Venting Through a Roof ALL ModelsPVC Schedule 40 vent piping Gas Piping Sediment TrapGAS Piping with GAS Piping with ALL Black Iron Pipe to GAS ControlInstallation Checklist ContdBefore Lighting the Pilot Operating Instructions Before the Water Heater will OperateBy this Water Heater For Your Safety If YOU Shell GAS LightingAwarning Before Lighting Propane L.R GAS Water AN Odorant iS Added to the GAS UsedOperating Instructions contd Whattodoif YousmellgasTemperature Regulation Operating Instructions contdSonunattendedin a bathtubor shower Service and Adjustment Tank Sediment CleaningBurner Inspection Oiling InstructionsService and Adjustment contd Gas Control Valve & Burner Assembly Replacement InformationTemperature-Pressure Relief Valve Operation DrainingDrain Valve Washer Replacement ServiceHousekeeping Start Up Conditions Strange SoundsThermal Expansion Troubleshooting Guide contd Operational ConditionsCondensation SMOKE/ODORHigh Temperature Shut OFF System Operational Conditions contdWater is TOO HOT Leakage Checkpoints AcautioniTroubleshooting Guide contd Thermostat and GAS Supply Check0RE Troubleshooting Guide contdAcaution Property DamageYes Page Power Miser TM 9 Power Vent GAS Water Heaters Parts Order ListPower Miser TM 9 Power Vent GAS Water Heaters Model Numbers Parts Order List contdParts Order List Parts Order List contd Part DescriptionWarranty MY-HOMIE