Kenmore 153.33429, 153.33459, 153.33449, 153.33439 owner manual Water Piping, Ae,Warning

Page 11

Installation Instructions (cont'd)

Water Piping

AWARNING

HOTTER WATER CAN SCAI._. Water heaters are intended to

produce hot water. Water _ to a temperature which will satisfyclothes washing, dishwathm_ and other sanitizing needs can scaldand permanently injure you upon contact. Some peo- ple are more likely to be permanently injured by hot water than other*. These includethe elderly, child_n, the infirm, or physical- ly/mentaily handicapped.If anyone usinghot water in your home fits into one of these groups or if there is a localcede or state law requiring a certain temperature water at the hot water _ then you must take speciaiprecautions In addition to usingthe lowest possil_etemperature setting that satisfiesyour hot water needs, a means suchas a mixing valve, should be usedat the hot water taps used by these people or at she water heater. Mixing valves are availableat plumbing supplyor hardware store_ Followman- ufacturers instructions for installation of the valves. Before changing the factory setting on the thermostat, read the "Temperature Regulation" section in this manual.

 

 

AE,WARNING

 

]

This water

heate_connected

to

any

heating

systems or component(s)

used with a

non-[

potable

water

heating appliance.

 

 

Look at the top cover of the water heater. The cold water inlet is markedcold. Put two or three turns of teflon tape

around the threaded end of the threaded_to-sweat coupling and around both ends of the 3A threaded nipple. Using flexi-

ble connectors, connect the cold water pipe to the coldwater inlet of the water heater.

NOTE: This water heater is super insulated to minimize heat loss from the tank. Further reduction in heat loss

can be accomplished by insulating the hot water lines from the water heater.

 

INSTALLATION

COMPLETED

USING

 

SEARS

INSTALLATION

KIT

 

 

 

SHUTOFF

 

CONNECTORS

Ig3

 

FLEXIBLE WATER

 

 

H_T OUTLET

 

 

COLD INLET

TO HOUSE

]

 

WATER LINE

 

 

THREADED TO

 

THREADED TO

SWEAT

COUPLING

 

SWEAT COUPLING

 

 

_,WARNING

.

]

 

 

Toxic chemicals

suc_reatment

 

of boders

[

NIPPLE

NIPPLE

or

non-potable

water

heating appliances

shall never

[

 

 

be

introduced

into a potable

water heating

system.

J

 

 

If a water heater is installed in a closed water supply system;

 

 

 

such as one having a back-flow preventer, check valve, water

 

 

 

meter with a check valve, etc.., in the cold water supply; means

 

 

 

shall be provided to control thermal expansion. Contact the

 

 

 

local utility or local Sears Service Center on how to control this

 

 

PRESSURE

situation.

 

 

 

 

 

 

 

 

 

 

 

 

RELIEF VALVE

NOTE: To ,protect against untimely corrosion of hot and

 

 

 

cold

water lattings, it is

strongly

recommended

that all-elec-

 

 

 

tric unions or couplings be installed on this water heater

when connected to copper pipe.

[]

 

The illustration shows the attachment of the water piping to the

water heater. The water heater is equipped with 3A" water connections.

PIPE (Do not cap or plug)

NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connec- tion. Do not solder the cold water supply line directly to the

cold water inlet. It will harm the dip tube and damage the tank.

Look at the top cover of the water heater. The water outlet is marked hot. Put two or three turns of teflon tape around the

threaded end of the threaded-to-sweat coupling and around both ends of the ¾" threaded nipple. Using flexible connec-

tors, connect the hot water pipe to the hot water outlet on the water heater.

_" AIR GAP

FLOOR DRAIN

11

Image 11
Contents Odorant is Added to the GAS Used by this Inat E R Heater For Your SafetyWhat to do if YOU Smell GAS Model NoDEATH, Serious Bodily INJURY, or Property Safety PrecautionsWater Heaters Equipped for ONE Type GAS Safety Precautions Safety Precautions Contents @ 90F Rise SpecificationsProduct Customer RespOnsibilitiesBasic Tools Materials and Basic Tools NeededMaterials Needed Cut with a hacksaw approximately Installation InstructionsRemoving the Old Water Heater DEATH,SERIOUSBODILYINJUR,OR Propertydamage Installation Instructions contdFacts to Consider About Location ALL AIR from Inside Buildings Installation Instructions contdAE,WARNING Water PipingPpe Temperature-Pressure Relief ValveVenting Filling the Water HeaterGas Piping Venting contdSediment Trap GAS Piping with Flexible ConnectorContd AwarningModel Rating Plate Installation ChecklistBefore Lighting the Pilot Before Lighting Propane LP. GAS Water Operating InstructionsLighting Check for LeaksNot Force Operating Instructions contdWhatto Doif Yousmellgas Controlsystemand any gas controlwhichhas been underwaterCanscaldand permanentlyinjureyouuponcontact.Somepeo Temperature RegulationHOT-Is a thermostat setting of approximately Hotter Water can SCALDWater heatersareintendedtoBurner Inspection Service and AdjustmentTank Sediment Cleaning Burner CleaningDrain Valve Washer Replacement Service and Adjustment contdTemperature-Pressure Relief Thermal Expansion Troubleshooting GuideStart Up Conditions CondensationSmelly Water Troubleshooting Guide contdStrange Sounds AIR in HOT Water FaucetsWater is TOO HOT High Temperature Shut OFF SystemContd Not Enough or no HOT WaterAcaution Leakage CheckpointsParts Order List Parts Order List contd Lightingpilot Warranty8OO-4.MY-HOME

153.33429, 153.33439, 153.33449, 153.33459 specifications

The Kenmore 153 series offers a range of powerful and versatile upright vacuums, specifically models 153.33439, 153.33459, 153.33429, and 153.33449. Each model presents unique features that cater to diverse cleaning needs, making them appealing choices for households seeking efficient cleaning solutions.

All models in the Kenmore 153 series are equipped with a robust motor that delivers strong suction power, allowing them to pick up dirt, debris, and pet hair with ease. The high-performance design ensures that even embedded dirt in carpets is effectively removed. Additionally, these vacuums come with a multi-surface cleaning capability, making them suitable for various floor types, including carpets, hardwoods, and tiles.

One of the standout technologies in the Kenmore 153 series is the advanced filtration system. Each vacuum is fitted with a HEPA filter that captures 99.97% of dust and allergens as small as 0.3 microns. This feature is particularly advantageous for allergy sufferers, ensuring cleaner air and a healthier living environment.

The vacuums also boast a user-friendly design, featuring a lightweight body that enhances maneuverability. The swivel steering allows users to navigate around furniture easily, while the telescoping wand extends for reach in hard-to-access areas, such as ceilings and corners. The convenient dusting brush and upholstery tool make the cleaning process seamless, ensuring no corner of the home is left untouched.

Another attractive aspect of the Kenmore 153 series is their noise-reduction technologies. The "quiet mode" feature allows for efficient cleaning without disturbing the household, making them ideal for any time of day, whether it's during nap times or late at night.

The sturdy construction of these vacuums ensures durability and longevity, paired with a sleek modern design that fits well within any home aesthetic. Each model offers adjustable height settings, allowing users to adapt the vacuum according to their cleaning preferences and the type of flooring being cleaned.

In summary, the Kenmore 153 series, featuring models 153.33439, 153.33459, 153.33429, and 153.33449, exemplifies versatility, power, and user-centric design. With their advanced technologies and robust features, these vacuums are well-suited for households looking to maintain cleanliness and improve indoor air quality. The Kenmore 153 series is worth considering for anyone in the market for a reliable vacuum cleaner.