Kenmore 153.33449, 153.33459 Installation Instructions contd, Facts to Consider About Location

Page 9

Installation Instructions (cont'd)

Facts to Consider About the

Location

You should carefully choose an indoor location for the new water heater, because the placement is a very important consid- eration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in mobile homes or outdoor installation.

Whether replacing an old water heater or putting the water

heater in a new location, the following critical points must be observed.

The location selected should be indoors as close as'practical to the gas vent or chimney to which the water heater vent is going to be connected, and as centralized with the _ater pip- ing system as possible. The water heater, as all water heaters, will eventually leak. Do not install without adequate drainage provisions where water flow will cause damage.

ACAUTION

WATER HEATERS EVENTUALLY LEAK: Installationof the water heater must be accomplishedin sucha manner that if the tank or any connectionsshouldleak,the flowof water will not causedamageto the structure.When suchlocationscan- not be avoided,a suitable drain pan shouldbe installedunder the water heater.Drain pansare availableat your localSears store. Such a drain pan must be not greater than 1½ inches deep, havea minimum length and width of at least 2 inches

greater than the water heater dimensionsand must be piped to anedeqeatedrain.The pan mustnot restrict combustionair flow.Under no circumstancesis the manufactureror Searsto

be held liable for any water damage in connectionwith this water heater.

AWARNING

INSTALLATIONSIN AREASWHERE FLAMMABLELIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED

GARAGES, STORAGE, AND UTILITY AREAS,"ETC): Flammableliquids(suchasgasoline,solvents,propane(LP) or

The location selection must provide adequate clearances for ser- vicing and proper operation of the waterheater.

AWARNING

This water heater mustnot be installeddirectlyon carpeting. Carpeting must be protected by a metal or wood panel beneath the appliance extendingbeyondthe full width and depth of the applianceby at least 3 inches(76.2mm) in any direction,or if the appliance isinstalledin an alcove or closet, the entiretloor mustbe coveredby the panel.Failureto heed this wam.ingmayresultin a Erehazard.

AWARNING

Minimum clearancesbetween the water heater and com- bustibleor non-combustibleconstructionare I" at the sides

and rear,4" at the front, and 6" from the vent pipe.Clearance from the top of the jacketis 18"on mostmodelg Note that a lesserdimensionmaybe allowedon somemodelL Referto the

labelon the water heater adjacentto the gascontrolvalvefor all clearance_

12" MAX

VENTILATION

AlE

OPENINGS

 

TOP VIEW

11

 

OF CLOSET

TOP VIEW ]" MIN.

__

WITHOUT DOOR

OF CLOS)SEIT

12 wMAX.

WITH DOOR

AIR DUCT

Figure I ]

butane, etc.), all of which emit flammable vapors, may be improperlystored or usedin suchareas.The gaswater heater

pilot light or main burnercanignitesuchvapors.The resulting flashbackand fire can causedeathor seriousburnsto anyonein the area,aswellaspropertydamage.

If installationin suchareasisyour onlyoption,then the installa- tion must be accomplishedin a way that the pilot flame and main burnerflameareelevatedfrom the floor at least18inches. While this may reducethe chancesof flammablevaporsfrom a floorspillbeingignited,gasolineand otherflammablesubstances shouldneverbe stored or usedin the same room or area con-

taininga gaswater heateror otheropenflameor sparkproduc- ingappliance.

NOTE: Flammablevaporsmay be drawnby air currentsfrom otherareasofthe structureto the appliance.

AWARNING

Propellants of aerosolspraysand volatile compounds,(clean- ers, chlorinebasedchemicals,refrigerants,etc.) in additionto beinghighlyflammablein manycases,will alsochangeto cor- rosive hydrochloricacid when exposed to the combustion productsof the water heater.The results can be hazardous, and alsocauseproductfailure.

AWARNING

A gaswater heater cannotoperateproperlywithout the cor- rect amount of air for combustionDo. not install in a confined

areasucha closet,unlessyou provideair asshownin the "Facts to ConsiderAbout the Location"section.Never obstructthe

Ilowofventilationair. If you haveany doubtsor questionsat all, callyour gascompanyFailureto. providethe properamount of combustionair canresult in a fire or explosionand cancause

DEATH,SERIOUSBODILYINJUR_,OR PROPERTYDAMAGE.

A, WARNING

If this water heater will be usedin beautyshops,barbershops, cleaningestablishments,or self-servicelaundries with dry cleaningequipment,it isimperativethat the water heater or water heatersbe installedso that combustionand ventilation air be takenfrom outsidethese areas.Refer to the "Facts to ConsiderAbout the Location"section of this manual and also the latestedition ofthe NationalFuelGasCode, ANSI Z223.1,

alsoreferred to as NFPA 54 for specificsprovided concerning air required.

Image 9
Contents What to do if YOU Smell GAS For Your SafetyModel No Odorant is Added to the GAS Used by this Inat E R HeaterSafety Precautions Water Heaters Equipped for ONE Type GASDEATH, Serious Bodily INJURY, or Property Safety Precautions Safety Precautions Contents Product SpecificationsCustomer RespOnsibilities @ 90F RiseMaterials and Basic Tools Needed Materials NeededBasic Tools Installation Instructions Removing the Old Water HeaterCut with a hacksaw approximately Installation Instructions contd Facts to Consider About LocationDEATH,SERIOUSBODILYINJUR,OR Propertydamage ALL AIR from Inside Buildings Installation Instructions contdAE,WARNING Water PipingPpe Temperature-Pressure Relief ValveVenting Filling the Water HeaterGas Piping Venting contdContd GAS Piping with Flexible ConnectorAwarning Sediment TrapInstallation Checklist Before Lighting the PilotModel Rating Plate Lighting Operating InstructionsCheck for Leaks Before Lighting Propane LP. GAS WaterWhatto Doif Yousmellgas Operating Instructions contdControlsystemand any gas controlwhichhas been underwater Not ForceHOT-Is a thermostat setting of approximately Temperature RegulationHotter Water can SCALDWater heatersareintendedto Canscaldand permanentlyinjureyouuponcontact.SomepeoTank Sediment Cleaning Service and AdjustmentBurner Cleaning Burner InspectionService and Adjustment contd Temperature-Pressure ReliefDrain Valve Washer Replacement Start Up Conditions Troubleshooting GuideCondensation Thermal ExpansionStrange Sounds Troubleshooting Guide contdAIR in HOT Water Faucets Smelly WaterContd High Temperature Shut OFF SystemNot Enough or no HOT Water Water is TOO HOTAcaution Leakage CheckpointsParts Order List Parts Order List contd Warranty 8OO-4.MY-HOMELightingpilot

153.33429, 153.33439, 153.33449, 153.33459 specifications

The Kenmore 153 series offers a range of powerful and versatile upright vacuums, specifically models 153.33439, 153.33459, 153.33429, and 153.33449. Each model presents unique features that cater to diverse cleaning needs, making them appealing choices for households seeking efficient cleaning solutions.

All models in the Kenmore 153 series are equipped with a robust motor that delivers strong suction power, allowing them to pick up dirt, debris, and pet hair with ease. The high-performance design ensures that even embedded dirt in carpets is effectively removed. Additionally, these vacuums come with a multi-surface cleaning capability, making them suitable for various floor types, including carpets, hardwoods, and tiles.

One of the standout technologies in the Kenmore 153 series is the advanced filtration system. Each vacuum is fitted with a HEPA filter that captures 99.97% of dust and allergens as small as 0.3 microns. This feature is particularly advantageous for allergy sufferers, ensuring cleaner air and a healthier living environment.

The vacuums also boast a user-friendly design, featuring a lightweight body that enhances maneuverability. The swivel steering allows users to navigate around furniture easily, while the telescoping wand extends for reach in hard-to-access areas, such as ceilings and corners. The convenient dusting brush and upholstery tool make the cleaning process seamless, ensuring no corner of the home is left untouched.

Another attractive aspect of the Kenmore 153 series is their noise-reduction technologies. The "quiet mode" feature allows for efficient cleaning without disturbing the household, making them ideal for any time of day, whether it's during nap times or late at night.

The sturdy construction of these vacuums ensures durability and longevity, paired with a sleek modern design that fits well within any home aesthetic. Each model offers adjustable height settings, allowing users to adapt the vacuum according to their cleaning preferences and the type of flooring being cleaned.

In summary, the Kenmore 153 series, featuring models 153.33439, 153.33459, 153.33429, and 153.33449, exemplifies versatility, power, and user-centric design. With their advanced technologies and robust features, these vacuums are well-suited for households looking to maintain cleanliness and improve indoor air quality. The Kenmore 153 series is worth considering for anyone in the market for a reliable vacuum cleaner.