Kenmore 153.331543, 153.331514 HA Filling the Water Heater, Venting, Water Damage Hazard

Page 14

OUTLET

 

COLD WATER

HOT WATER

 

 

 

 

VALVE

HOT

COLD

TEMPERATURE=PRESSURE

 

 

RELIEF VALVE

 

 

(OPTIONAL TOP T & P RELIEF

DRAFT HOOD

VALVE NOT SHOWN)

The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot.

If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions,

and replace the temperature-pressure relief valve with a new one.

DISHCARGE PIPE

(DO NOT CAP OR PLUG)

DRAIN VALVE

_ FLOOR DRAIN

FIGURE16,

Water Damage Hazard

Temperature-pressure relief valve discharge pipe must terminate at adequate drain.

The Discharge Pipe:

Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Shall not be plugged or blocked.

Shall be of material listed for hot water distribution.

Shall be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe.

Shall terminate at an adequate drain.

Shall not have any valve between the relief valve and tank.

Water temperature over 125°F (52°C) can cause severe burns

instantly resulting in severe injury ordeath.

Children, the elderly, and the physically or mentally disabled are at highest riskfor scald injury.

Feel water before bathing or showering.

Temperature limiting valves are available.

Read instruction manual for safe temperature setting.

Filling the Water Heater

Property Damage Hazard

• Avoid water heater damage.

•Fili tank with water before operating.

Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" gas to the water heater.

To fill the water heater with water:

Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.

Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

Check all water piping and connections for leaks. Repair as needed.

Venting

VENT DAMPERS - Any vent damper, whether it is operated thermally or otherwise must be removed if its use inhibits proper drafting of the water heater.

Thermally Operated Vent Dampers: Gas-fired water heaters having thermal efficiency in excess of 80% may produce a relatively low flue gas temperature. Such temperatures may not be high enough to properly open thermally operated vent dampers. This would cause spillage of the flue gases and may cause carbon monoxide poisoning.

Vent dampers must bear evidence of certification as complying with the current edition of the American National Standard

ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically

14

Image 14
Contents Power Miser TM GAS Water Heater Model noImportant Definitions Explosion Hazard Improper installation and use may result in property damageFire Hazard Fire or Explosion HazardMaterial Needed Basic Tools Lighting & Operating Label Temperature RegulationDrain Valve Washer Replacement Relief ValveJackettop CapacityPerhour Inches Heightto Model Number Gals Ltrs GAS Rate Basic Tools Additional Tools Needed When Sweat SolderingMaterials Needed View Install in Accordance with Local CodesThermostat Pilot & Main BurnerRGURE4 Removing the Old Water HeaterRGURE3 RGURE5Rgure Facts to Consider About LocationFire or Explosion Hazard Front View Door Insulation BlanketsBreathing Hazard Carbon Monoxide Gas RGURE12 ALL AIR from Inside BuildingsRGURE11 RGURE13Toxic Chemical Hazard Water PipingProperty Damage Hazard Do not connect to non-potablewater systemInsulation Flue Pipe Temperature-Pressure Relief ValveInstallation Completed Using Installation KIT FloordrainWater Damage Hazard Filling the Water HeaterVenting Rgure RgureiGas Piping Fire and Explosion HazardCAP Sediment TrapsOptional Valve What to do if YOU Smell GAS Topknob GAS ControlRGURE22 Temperature RegulationRGURE21 Carbon Monoxide and Fire Hazard Tank Sediment Cleaning Burner InspectionVent System Inspection RGURE23Anode Rod Inspection Temperature-Pressure Relief Valve OperationHousekeeping DrainingDrain Valve Washer Replacement ServiceThermal Expansion Property Damage Hazard Thermal Expansion Tank SpecificationsStart Up Conditions Strange SoundsCondension High Temperature Shut Off SystemOperational Conditions Smoke / OdorOperational Conditions Leakage Checkpoints Ventgasodors HOT WaterRumbling Burner Assembly This is a Repair Parts LIST, not a Packing ListSears Installation Service Full ONE Year Warranty on Water HeaterLimited Warranty on Parts Limited Warranty on TAN KS That Leak

153.331413 HA, 153.331514 HA, 153.331543 specifications

The Kenmore model 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units are popular options for consumers seeking reliable and efficient cooling solutions. These models are renowned for their innovative features and robust performance, catering to a range of residential needs.

One of the standout characteristics of the Kenmore 153 series is its energy efficiency. Designed with advanced technology, these air conditioners are equipped with high SEER ratings. This means they consume less energy while providing optimal cooling, ultimately leading to reduced utility bills. Additionally, they utilize environmentally-friendly refrigerants, aligning with modern regulations for eco-friendly appliances.

Another notable feature is the adjustable cooling settings. Users can easily customize their comfort levels with multiple fan speeds and temperature settings. This flexibility allows for energy savings and tailored cooling according to the specific needs of different rooms or times of day.

The Kenmore 153.331514 HA model stands out as a heavy-duty option, suitable for larger spaces, boasting a higher BTU rating for enhanced cooling power. Its smart technology integration facilitates remote control access through smartphones, allowing users to adjust settings even when they are away from home.

The Kenmore 153.331413 HA, meanwhile, is an excellent choice for medium-sized areas, providing efficient cooling without overpowering smaller spaces. Its user-friendly digital display and programmable timers enhance convenience, ensuring that the air conditioning operates only when necessary.

Lastly, the Kenmore 153.331543 model features a sleek and modern design that blends seamlessly with home decor. Its quiet operation ensures that it does not disrupt daily activities, making it ideal for living rooms and bedrooms.

The durability of these air conditioning units is another key aspect. Built with high-quality materials, they promise longevity and continuous performance, reducing the need for frequent repairs or replacements.

In summary, the Kenmore 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units offer a combination of efficiency, flexibility, and durability. With features tailored to enhance user experience and comfort, they stand out as top choices for those seeking effective home cooling solutions.