Kenmore 153.331514 HA, 153.331413 HA, 153.331543 What to do if YOU Smell GAS, Topknob GAS Control

Page 18

FOR YOUR SAFETY READ BEFORE LIGHTING

I WARNING=,fyoudenotfo"owthese=nstructexact=yons f reor

explosion may result causing property damage, personal injury or loss of life.

BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.

A.This appliance has a pilot which must be lighted by hand When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier'sinstructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob wili not push in or turn by hand, don't try to repair it. call a qualified service

technician. Force or attempted repair may result in a fire or explosion.

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater

LIGHTING INSTRUCTIONS

GAS CONTROL KNOB

FIGURE "A"

FIGURE "B"

FIGURE "C"

MAIN BURNER

IGNITER

TH ERMOCOUpLE

GENERATOR

_PIE2'O

"OFF POSITION "PILOT" POSITION "ON" F=O_ITION

THERMOSTAT

DEAL

TOPKNOB

GAS CONTROL

1._'l_ STOP! Read the safety information above on this label

2.Set the thermostat to lowest setting (PILOT LIGHTING). Turn thermostat dial fully clockwise _ until it stops.

3.Push the gas control knob down slightly and turn clockwise

to"OFF", SEE FIGURE "A".

NOTE: Knob CANNOT be turned from "PILOT" to "OFF" unless it is pushed down slightly. Do not force.

4.Remove the outer burner door located below the gas control.

5.Wait five (5) minutes to clear oat any gas. If you then

smell gas. (_) STOP! Follow"B" in the safety information above on this label. It you don'tsmell gas, go to next step.

6.This unit is equipped with a push button pilot igniter, which is used to light the pilot. Locate the igniter on the gas control.

7.Turn gascontrol knob counterclockwise _ to"PILOT", SEE FIGURE "B".

8.The pilot is located on the right side of the burner. It can be located by looking through the glass view port while pressing the piezo igniter button several times. Look for a spark at the pilot location, FIGURE"D'.

FIGURE"D"

9.Once the pilot has been found, push the gas knob al! the way down. Immediately press the pilot igniter button rapidly

(4)to (5) times, if the pilot will not light, repeat step (3)

through (9).

10Continue to hold the gas control knob down for about one

(1)minute after the pilot is lit. Release the gas control knob and it will pop back up. Pilot should remain lit. If it goes out. repeat step (3) through (9). It may take several minutes for air to clear the lines before the pilot will light.

It knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas

control knob cieckwise _ to "OFF" and call your service technician or gas supplier. SEE FIGURE "A".

11.Once the pilot flame is established replace the outer burner door.

12 At arms length away, turn gas control knob counterclockwise t_"_ to"ON". SEE FIGURE "C".

13 Set thermostat to desired setting

scald injury. Consult the instruction manual DANGER: Hotter water increases the risk of before changing temperature,

/_to "OFF". Do not force. SEE FIGURE "A".

18

Image 18
Contents Power Miser TM GAS Water Heater Model noImportant Definitions Explosion Hazard Improper installation and use may result in property damageFire Hazard Fire or Explosion HazardMaterial Needed Basic Tools Lighting & Operating Label Temperature RegulationDrain Valve Washer Replacement Relief ValveCapacity Perhour Inches Heightto Model Number Gals Ltrs GAS RateJackettop Additional Tools Needed When Sweat Soldering Materials NeededBasic Tools View Install in Accordance with Local CodesThermostat Pilot & Main BurnerRGURE4 Removing the Old Water HeaterRGURE3 RGURE5Facts to Consider About Location Fire or Explosion HazardRgure Insulation Blankets Breathing Hazard Carbon Monoxide GasFront View Door RGURE12 ALL AIR from Inside BuildingsRGURE11 RGURE13Toxic Chemical Hazard Water PipingProperty Damage Hazard Do not connect to non-potablewater systemInsulation Flue Pipe Temperature-Pressure Relief ValveInstallation Completed Using Installation KIT FloordrainFilling the Water Heater VentingWater Damage Hazard Rgure RgureiGas Piping Fire and Explosion HazardSediment Traps Optional ValveCAP What to do if YOU Smell GAS Topknob GAS ControlTemperature Regulation RGURE21RGURE22 Carbon Monoxide and Fire Hazard Tank Sediment Cleaning Burner InspectionVent System Inspection RGURE23Anode Rod Inspection Temperature-Pressure Relief Valve OperationHousekeeping DrainingDrain Valve Washer Replacement ServiceThermal Expansion Property Damage Hazard Thermal Expansion Tank SpecificationsStart Up Conditions Strange SoundsCondension High Temperature Shut Off SystemOperational Conditions Smoke / OdorOperational Conditions Leakage Checkpoints HOT Water RumblingVentgasodors Burner Assembly This is a Repair Parts LIST, not a Packing ListSears Installation Service Full ONE Year Warranty on Water HeaterLimited Warranty on Parts Limited Warranty on TAN KS That Leak

153.331413 HA, 153.331514 HA, 153.331543 specifications

The Kenmore model 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units are popular options for consumers seeking reliable and efficient cooling solutions. These models are renowned for their innovative features and robust performance, catering to a range of residential needs.

One of the standout characteristics of the Kenmore 153 series is its energy efficiency. Designed with advanced technology, these air conditioners are equipped with high SEER ratings. This means they consume less energy while providing optimal cooling, ultimately leading to reduced utility bills. Additionally, they utilize environmentally-friendly refrigerants, aligning with modern regulations for eco-friendly appliances.

Another notable feature is the adjustable cooling settings. Users can easily customize their comfort levels with multiple fan speeds and temperature settings. This flexibility allows for energy savings and tailored cooling according to the specific needs of different rooms or times of day.

The Kenmore 153.331514 HA model stands out as a heavy-duty option, suitable for larger spaces, boasting a higher BTU rating for enhanced cooling power. Its smart technology integration facilitates remote control access through smartphones, allowing users to adjust settings even when they are away from home.

The Kenmore 153.331413 HA, meanwhile, is an excellent choice for medium-sized areas, providing efficient cooling without overpowering smaller spaces. Its user-friendly digital display and programmable timers enhance convenience, ensuring that the air conditioning operates only when necessary.

Lastly, the Kenmore 153.331543 model features a sleek and modern design that blends seamlessly with home decor. Its quiet operation ensures that it does not disrupt daily activities, making it ideal for living rooms and bedrooms.

The durability of these air conditioning units is another key aspect. Built with high-quality materials, they promise longevity and continuous performance, reducing the need for frequent repairs or replacements.

In summary, the Kenmore 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units offer a combination of efficiency, flexibility, and durability. With features tailored to enhance user experience and comfort, they stand out as top choices for those seeking effective home cooling solutions.