Kenmore 153.331413 HA Material Needed Basic Tools, Relief Valve, Filling the Water Heater, Guide

Page 4

SAFE

INSTALLATION,

USE AND SERVICE

2

SAFETY

PRECAUTIONS

3

TABLE

OF CONTENTS

................................................................................................................................

4

CUSTOMER

 

RESPONSIBILITIES

5

PRODUCT

SPECIFICATIONS

5

MATERIALS

AND

BASIC TOOLS NEEDED

6

Material Needed

6

Basic Tools

.............................................................................................................................................................

 

6

TYPICAL

INSTALLATION

7

INSTALLATION

INSTRUCTIONS

8-16

Removing

the Old Water Heater

8

Facts to Consider About the Location

9-10

Insulation

Jackets

10

Combustion Air and Ventilation Appliances

 

in Unconfined Spaces

............................................................................................................................................

10

Combustion Air and Ventilation Appliances

 

in Confined

Spaces

11-12

Water

Piping

 

12-13

Temperature Pressure

Relief Valve

13-14

Filling the Water Heater

14

Venting

 

 

 

14-15

Gas Piping

.......................................................................................................................................................

 

15-16

Sediment Trap

 

16-17

OPERATING

 

INSTRUCTIONS

18-19

Lighting & Operating

Label

18

Temperature Regulation

19

SERVICE

AND ADJUSTMENT

20-22

Tank (Sediment) Cleaning

20

Venting System

Inspection

20

Burner

Inspection

20

Burner Cleaning

20

Housekeeping

 

20-21

Anode Rod Inspection

...........................................................................................................................................

21

Temperature-Pressure

Relief Valve Operation

21

Draining

 

 

 

21-22

Drain Valve Washer Replacement

22

Service

 

 

 

_

TROUBLESHOOTING

GUIDE

23-26

Start Up Conditions

23-24

 

Thermal Expansion

23

 

Strange Sounds

23

 

Draft Hood Operation

23-24

 

Condensation

24

 

Smoke/Odor

24

Operational

Conditions

24-25

 

Smelly Odor

24

 

Air in Hot Water Faucets

25

 

High Temperature

Shut-Off System

24

 

Leakage Checkpoints

25

Troubleshooting

Guide

26

PARTS

ORDER

LIST

.................................................................................................................................

27

WARRANTY

................................................................................................................................................

 

 

28

Image 4
Contents Power Miser TM GAS Water Heater Model noImportant Definitions Improper installation and use may result in property damage Fire HazardExplosion Hazard Fire or Explosion HazardLighting & Operating Label Temperature Regulation Drain Valve Washer ReplacementMaterial Needed Basic Tools Relief ValvePerhour Inches Heightto Model Number Gals Ltrs GAS Rate CapacityJackettop Materials Needed Additional Tools Needed When Sweat SolderingBasic Tools Install in Accordance with Local Codes ThermostatView Pilot & Main BurnerRemoving the Old Water Heater RGURE3RGURE4 RGURE5Fire or Explosion Hazard Facts to Consider About LocationRgure Breathing Hazard Carbon Monoxide Gas Insulation BlanketsFront View Door ALL AIR from Inside Buildings RGURE11RGURE12 RGURE13Water Piping Property Damage HazardToxic Chemical Hazard Do not connect to non-potablewater systemTemperature-Pressure Relief Valve Installation Completed Using Installation KITInsulation Flue Pipe FloordrainVenting Filling the Water HeaterWater Damage Hazard Rgure RgureiGas Piping Fire and Explosion HazardOptional Valve Sediment TrapsCAP What to do if YOU Smell GAS Topknob GAS ControlRGURE21 Temperature RegulationRGURE22 Tank Sediment Cleaning Burner Inspection Vent System InspectionCarbon Monoxide and Fire Hazard RGURE23Temperature-Pressure Relief Valve Operation HousekeepingAnode Rod Inspection DrainingDrain Valve Washer Replacement ServiceThermal Expansion Tank Specifications Start Up ConditionsThermal Expansion Property Damage Hazard Strange SoundsHigh Temperature Shut Off System Operational ConditionsCondension Smoke / OdorOperational Conditions Leakage Checkpoints Rumbling HOT WaterVentgasodors Burner Assembly This is a Repair Parts LIST, not a Packing ListFull ONE Year Warranty on Water Heater Limited Warranty on PartsSears Installation Service Limited Warranty on TAN KS That Leak

153.331413 HA, 153.331514 HA, 153.331543 specifications

The Kenmore model 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units are popular options for consumers seeking reliable and efficient cooling solutions. These models are renowned for their innovative features and robust performance, catering to a range of residential needs.

One of the standout characteristics of the Kenmore 153 series is its energy efficiency. Designed with advanced technology, these air conditioners are equipped with high SEER ratings. This means they consume less energy while providing optimal cooling, ultimately leading to reduced utility bills. Additionally, they utilize environmentally-friendly refrigerants, aligning with modern regulations for eco-friendly appliances.

Another notable feature is the adjustable cooling settings. Users can easily customize their comfort levels with multiple fan speeds and temperature settings. This flexibility allows for energy savings and tailored cooling according to the specific needs of different rooms or times of day.

The Kenmore 153.331514 HA model stands out as a heavy-duty option, suitable for larger spaces, boasting a higher BTU rating for enhanced cooling power. Its smart technology integration facilitates remote control access through smartphones, allowing users to adjust settings even when they are away from home.

The Kenmore 153.331413 HA, meanwhile, is an excellent choice for medium-sized areas, providing efficient cooling without overpowering smaller spaces. Its user-friendly digital display and programmable timers enhance convenience, ensuring that the air conditioning operates only when necessary.

Lastly, the Kenmore 153.331543 model features a sleek and modern design that blends seamlessly with home decor. Its quiet operation ensures that it does not disrupt daily activities, making it ideal for living rooms and bedrooms.

The durability of these air conditioning units is another key aspect. Built with high-quality materials, they promise longevity and continuous performance, reducing the need for frequent repairs or replacements.

In summary, the Kenmore 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units offer a combination of efficiency, flexibility, and durability. With features tailored to enhance user experience and comfort, they stand out as top choices for those seeking effective home cooling solutions.