2.CLOSEthecoldwaterinletvalvetothewaterheater.

3.OPENanearbyhotwaterfaucetandleaveopentoallowfor draining.

4.Connecta hosetothedrainvalveandterminatetoan adequatedrain.

5.OPENthewaterheaterdrainvalvetoallowfortankdraining.

NOTE:Ifthewaterheaterisgoingtobeshutdownand

drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain.

6.Close the drain valve.

7.Follow instructions in the Fifling The Water heatersectien.

8.Fellow the lighting instructions in the Lighting section to restart the water heater.

5.Screw the handle and cap assembly back into the drain

valve and retighten using a wrench. DO NOT OVER TIGHTEN.

6.Follow instructions in the Filling The Water Heater section.

7.Check for leaks.

8.Follow the lighting instructions in the Lighting section to restart the water heater.

_HANDLEAND

_ CAPASSEMBLY

WASHER

FIGURE 25.

Drain Valve Washer Replacement

(See Figure 25)

1.Tum "OFF" gas supply to water heater.

2.Follow "Draining" instructions.

3.Turning counter clockwise ( _ ), remove the hex cap below the screw handle.

4.Remove the washer and put the new one in place.

Service

Before calling for repair service, read the Start Up Conditions and Operational Conditions found in the Troubleshooting Guide of this manual.

If a condition persists or you are uncertain about the operation of the water heater, let the Sears Service Center check it out.

Contact Sears Service Center at:

1-800-4-MY-HOME (1-800-469-4663).

22

Image 22
Contents Power Miser TM GAS Water Heater Model noImportant Definitions Explosion Hazard Improper installation and use may result in property damageFire Hazard Fire or Explosion HazardMaterial Needed Basic Tools Lighting & Operating Label Temperature RegulationDrain Valve Washer Replacement Relief ValvePerhour Inches Heightto Model Number Gals Ltrs GAS Rate CapacityJackettop Materials Needed Additional Tools Needed When Sweat SolderingBasic Tools View Install in Accordance with Local CodesThermostat Pilot & Main BurnerRGURE4 Removing the Old Water HeaterRGURE3 RGURE5Fire or Explosion Hazard Facts to Consider About LocationRgure Breathing Hazard Carbon Monoxide Gas Insulation BlanketsFront View Door RGURE12 ALL AIR from Inside BuildingsRGURE11 RGURE13Toxic Chemical Hazard Water PipingProperty Damage Hazard Do not connect to non-potablewater systemInsulation Flue Pipe Temperature-Pressure Relief ValveInstallation Completed Using Installation KIT FloordrainVenting Filling the Water HeaterWater Damage Hazard Rgure RgureiGas Piping Fire and Explosion HazardOptional Valve Sediment TrapsCAP What to do if YOU Smell GAS Topknob GAS ControlRGURE21 Temperature RegulationRGURE22 Carbon Monoxide and Fire Hazard Tank Sediment Cleaning Burner InspectionVent System Inspection RGURE23Anode Rod Inspection Temperature-Pressure Relief Valve OperationHousekeeping DrainingDrain Valve Washer Replacement ServiceThermal Expansion Property Damage Hazard Thermal Expansion Tank SpecificationsStart Up Conditions Strange SoundsCondension High Temperature Shut Off SystemOperational Conditions Smoke / OdorOperational Conditions Leakage Checkpoints Rumbling HOT WaterVentgasodors Burner Assembly This is a Repair Parts LIST, not a Packing ListSears Installation Service Full ONE Year Warranty on Water HeaterLimited Warranty on Parts Limited Warranty on TAN KS That Leak

153.331413 HA, 153.331514 HA, 153.331543 specifications

The Kenmore model 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units are popular options for consumers seeking reliable and efficient cooling solutions. These models are renowned for their innovative features and robust performance, catering to a range of residential needs.

One of the standout characteristics of the Kenmore 153 series is its energy efficiency. Designed with advanced technology, these air conditioners are equipped with high SEER ratings. This means they consume less energy while providing optimal cooling, ultimately leading to reduced utility bills. Additionally, they utilize environmentally-friendly refrigerants, aligning with modern regulations for eco-friendly appliances.

Another notable feature is the adjustable cooling settings. Users can easily customize their comfort levels with multiple fan speeds and temperature settings. This flexibility allows for energy savings and tailored cooling according to the specific needs of different rooms or times of day.

The Kenmore 153.331514 HA model stands out as a heavy-duty option, suitable for larger spaces, boasting a higher BTU rating for enhanced cooling power. Its smart technology integration facilitates remote control access through smartphones, allowing users to adjust settings even when they are away from home.

The Kenmore 153.331413 HA, meanwhile, is an excellent choice for medium-sized areas, providing efficient cooling without overpowering smaller spaces. Its user-friendly digital display and programmable timers enhance convenience, ensuring that the air conditioning operates only when necessary.

Lastly, the Kenmore 153.331543 model features a sleek and modern design that blends seamlessly with home decor. Its quiet operation ensures that it does not disrupt daily activities, making it ideal for living rooms and bedrooms.

The durability of these air conditioning units is another key aspect. Built with high-quality materials, they promise longevity and continuous performance, reducing the need for frequent repairs or replacements.

In summary, the Kenmore 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units offer a combination of efficiency, flexibility, and durability. With features tailored to enhance user experience and comfort, they stand out as top choices for those seeking effective home cooling solutions.