Kenmore 153.331514 HA Facts to Consider About Location, Fire or Explosion Hazard, Rgure

Page 9

Facts to Consider About

the Location

Carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation,

Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed:

Select a location indoors as close as practical to the gas vent or chimney to which the water heater vent is going to be connected, and as centralized with the water piping system as possible.

Selected location must provide adequate clearances for servicing and proper operation of the water heater.

Property Damage Hazard

Allwaterheaterseventuallyleak

De notinstallwithout adequatedrainage

Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local Sears or hardware store. Such a drain pan must have a minimum length and width of at least 2 inches (51 mm) greater that the water heater dimensions and must be

piped to an adequate drain. The pan must not restrict combustion air flow.

heater's pilot light or main burner. The resulting flashback and fire can cause death or serious burns to anyone in the area. Even though this water heater is a flammable vapors ignition resistant water heater and is designed to reduce the chances of flammable vapors being ignited, gasoline and other flammable substances should never be stored or used in the same vicinity or area containing a gas water heater or other open flame or spark producing appliance.

Also, the water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle.

For continued protection against risk of fire:

• Do not install water heater on

I i_carpeted floor,

Fire Hazard

Do not operate water heater if flood damaged.

This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor

must be covered by the panel. Failure to heed this warning may result in a fire hazard.

Fire or Explosion Hazard

using or servicing water heater.

Improper use may result in fire or explosion.

Maintain required clearances to combustibles.

Fire or Explosion Hazard

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance,

Avoid all ignition sources if you smell LP gas.

Do not expose water heater control to excessive gas pressure

Use only gas shown on rating plate.

Maintain required clearances to combustibles,

Keep ignition sources away from faucets after

installing, using or servicing

,, extendedReadperiodinstructionof non-usemanual. before water heater.

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED

(GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable liquids (such as gasoline, solvents, propane [LP or butane, etc.] and other substances such as adhesives, etc.) emit flammable vapors which can be ignited by a gas water

Minimum clearances between the water heater and combustible

construction are 0 inch at the sides and rear, 4 inches (102 mm) at the front, and 6 inches (153 mm) from the vent pipe, see Figure 8. Clearance from the top of the jacket is 12 inches (305 mm) on most models. Note that a lesser dimension may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater.

TOP VIEW

TOP

VIEW

OF CLOSET

OF CLOSET

WITHOUT DOOR

WITH

DOOR

I I 0" MIN.

4" MIN.

 

4 mm)

 

0" MIN.

RGURE&

9

Image 9
Contents Model no Power Miser TM GAS Water HeaterImportant Definitions Fire Hazard Improper installation and use may result in property damageExplosion Hazard Fire or Explosion HazardDrain Valve Washer Replacement Lighting & Operating Label Temperature RegulationMaterial Needed Basic Tools Relief ValveCapacity Perhour Inches Heightto Model Number Gals Ltrs GAS RateJackettop Additional Tools Needed When Sweat Soldering Materials NeededBasic Tools Thermostat Install in Accordance with Local CodesView Pilot & Main BurnerRGURE3 Removing the Old Water HeaterRGURE4 RGURE5Facts to Consider About Location Fire or Explosion HazardRgure Insulation Blankets Breathing Hazard Carbon Monoxide GasFront View Door RGURE11 ALL AIR from Inside BuildingsRGURE12 RGURE13Property Damage Hazard Water PipingToxic Chemical Hazard Do not connect to non-potablewater systemInstallation Completed Using Installation KIT Temperature-Pressure Relief ValveInsulation Flue Pipe FloordrainFilling the Water Heater VentingWater Damage Hazard Rgurei RgureFire and Explosion Hazard Gas PipingSediment Traps Optional ValveCAP Topknob GAS Control What to do if YOU Smell GASTemperature Regulation RGURE21RGURE22 Vent System Inspection Tank Sediment Cleaning Burner InspectionCarbon Monoxide and Fire Hazard RGURE23Housekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingService Drain Valve Washer ReplacementStart Up Conditions Thermal Expansion Tank SpecificationsThermal Expansion Property Damage Hazard Strange SoundsOperational Conditions High Temperature Shut Off SystemCondension Smoke / OdorOperational Conditions Leakage Checkpoints HOT Water RumblingVentgasodors This is a Repair Parts LIST, not a Packing List Burner AssemblyLimited Warranty on Parts Full ONE Year Warranty on Water HeaterSears Installation Service Limited Warranty on TAN KS That Leak

153.331413 HA, 153.331514 HA, 153.331543 specifications

The Kenmore model 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units are popular options for consumers seeking reliable and efficient cooling solutions. These models are renowned for their innovative features and robust performance, catering to a range of residential needs.

One of the standout characteristics of the Kenmore 153 series is its energy efficiency. Designed with advanced technology, these air conditioners are equipped with high SEER ratings. This means they consume less energy while providing optimal cooling, ultimately leading to reduced utility bills. Additionally, they utilize environmentally-friendly refrigerants, aligning with modern regulations for eco-friendly appliances.

Another notable feature is the adjustable cooling settings. Users can easily customize their comfort levels with multiple fan speeds and temperature settings. This flexibility allows for energy savings and tailored cooling according to the specific needs of different rooms or times of day.

The Kenmore 153.331514 HA model stands out as a heavy-duty option, suitable for larger spaces, boasting a higher BTU rating for enhanced cooling power. Its smart technology integration facilitates remote control access through smartphones, allowing users to adjust settings even when they are away from home.

The Kenmore 153.331413 HA, meanwhile, is an excellent choice for medium-sized areas, providing efficient cooling without overpowering smaller spaces. Its user-friendly digital display and programmable timers enhance convenience, ensuring that the air conditioning operates only when necessary.

Lastly, the Kenmore 153.331543 model features a sleek and modern design that blends seamlessly with home decor. Its quiet operation ensures that it does not disrupt daily activities, making it ideal for living rooms and bedrooms.

The durability of these air conditioning units is another key aspect. Built with high-quality materials, they promise longevity and continuous performance, reducing the need for frequent repairs or replacements.

In summary, the Kenmore 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units offer a combination of efficiency, flexibility, and durability. With features tailored to enhance user experience and comfort, they stand out as top choices for those seeking effective home cooling solutions.