Kenmore 153.331543 Capacity, Perhour Inches Heightto Model Number Gals Ltrs GAS Rate, Jackettop

Page 5

Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME ®.

They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers GAMA - Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA

Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).

Read the"Safety Precautions" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It

could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE A'n'EMPTING

TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1.

Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.

Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.

 

 

 

 

 

RECOVERY

MINIMUM

 

DIMENSIONS

 

TANK

'TYPE

 

RATE GALS,

VENTPIPE

DIAMETER

IN INCHES (mm)

 

CAPACITY

OF

BllJ

PERHOUR

INCHES

INCHES

HEIGHTTO

MODEL NUMBER

IN GALS (LTRS)

GAS

RATE

@ 90°F RISE

(mm)

(mm)

JACKETTOP

153331413HA

40(151)

NATURAL

40,000

44.9

3"(76)or

 

4"(102)

201/2"(521)

58"(1,473)

153,331443

40(151)

NATURAL

40,000

44.9

3"(76)or

 

4"(102)

201/2"(521)

58"(1,473)

153,331514 HA

50

(189)

NATURAL

40,000

44.9

3" (76)

or

4" (102)

22" (558)

59

1/2" (1,511)

153,331543

50

(189)

NATURAL

40,000

44.9

3" (76)

or

4" (102)

22" (558)

59

1/2" (1,511)

Image 5
Contents Model no Power Miser TM GAS Water HeaterImportant Definitions Fire Hazard Improper installation and use may result in property damageExplosion Hazard Fire or Explosion HazardDrain Valve Washer Replacement Lighting & Operating Label Temperature RegulationMaterial Needed Basic Tools Relief ValveJackettop CapacityPerhour Inches Heightto Model Number Gals Ltrs GAS Rate Basic Tools Additional Tools Needed When Sweat SolderingMaterials Needed Thermostat Install in Accordance with Local CodesView Pilot & Main BurnerRGURE3 Removing the Old Water HeaterRGURE4 RGURE5Rgure Facts to Consider About LocationFire or Explosion Hazard Front View Door Insulation BlanketsBreathing Hazard Carbon Monoxide Gas RGURE11 ALL AIR from Inside BuildingsRGURE12 RGURE13Property Damage Hazard Water PipingToxic Chemical Hazard Do not connect to non-potablewater systemInstallation Completed Using Installation KIT Temperature-Pressure Relief ValveInsulation Flue Pipe FloordrainWater Damage Hazard Filling the Water HeaterVenting Rgurei RgureFire and Explosion Hazard Gas PipingCAP Sediment TrapsOptional Valve Topknob GAS Control What to do if YOU Smell GASRGURE22 Temperature RegulationRGURE21 Vent System Inspection Tank Sediment Cleaning Burner InspectionCarbon Monoxide and Fire Hazard RGURE23Housekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingService Drain Valve Washer ReplacementStart Up Conditions Thermal Expansion Tank SpecificationsThermal Expansion Property Damage Hazard Strange SoundsOperational Conditions High Temperature Shut Off SystemCondension Smoke / OdorOperational Conditions Leakage Checkpoints Ventgasodors HOT WaterRumbling This is a Repair Parts LIST, not a Packing List Burner AssemblyLimited Warranty on Parts Full ONE Year Warranty on Water HeaterSears Installation Service Limited Warranty on TAN KS That Leak

153.331413 HA, 153.331514 HA, 153.331543 specifications

The Kenmore model 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units are popular options for consumers seeking reliable and efficient cooling solutions. These models are renowned for their innovative features and robust performance, catering to a range of residential needs.

One of the standout characteristics of the Kenmore 153 series is its energy efficiency. Designed with advanced technology, these air conditioners are equipped with high SEER ratings. This means they consume less energy while providing optimal cooling, ultimately leading to reduced utility bills. Additionally, they utilize environmentally-friendly refrigerants, aligning with modern regulations for eco-friendly appliances.

Another notable feature is the adjustable cooling settings. Users can easily customize their comfort levels with multiple fan speeds and temperature settings. This flexibility allows for energy savings and tailored cooling according to the specific needs of different rooms or times of day.

The Kenmore 153.331514 HA model stands out as a heavy-duty option, suitable for larger spaces, boasting a higher BTU rating for enhanced cooling power. Its smart technology integration facilitates remote control access through smartphones, allowing users to adjust settings even when they are away from home.

The Kenmore 153.331413 HA, meanwhile, is an excellent choice for medium-sized areas, providing efficient cooling without overpowering smaller spaces. Its user-friendly digital display and programmable timers enhance convenience, ensuring that the air conditioning operates only when necessary.

Lastly, the Kenmore 153.331543 model features a sleek and modern design that blends seamlessly with home decor. Its quiet operation ensures that it does not disrupt daily activities, making it ideal for living rooms and bedrooms.

The durability of these air conditioning units is another key aspect. Built with high-quality materials, they promise longevity and continuous performance, reducing the need for frequent repairs or replacements.

In summary, the Kenmore 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units offer a combination of efficiency, flexibility, and durability. With features tailored to enhance user experience and comfort, they stand out as top choices for those seeking effective home cooling solutions.