Kenmore 153.330401 owner manual Operating Instructions contd, Temperature Regulation

Page 19

Operating Instructions (cont'd)

Temperature Regulation

Due to the nature of the typical gas water heater, the water tem- Foerature in certain situations may vary up to 30°F higher or wet at the point of use such as, bathtubs, showers, sink, etc.

This means that when the temperature adjustment dial is set at the mark approximating 120°F, the actual water temperature at any hot water tap could be as high as 150°F or as low as 90°E

Any water heaters intended purpose Is to heat water. Hot ware is needed for cleaning (bodies, dishes, clothing). Hot water will

present a scald hazard. Dejpending on the time element, and the

people involved (normaladults, children, toddlers, elderly, infirm, etc.) scalding may occur at different temperatures.

AWARNING

HOTTER WATERCAN SCALD:Water heatersare intendedto producehot water.Water heated to a temperaturewhichwill satisfyclotheswashing,dishwashing,and othersanitizingneeds canscaldand permanentlyinjureyou uponcontact.Somepeo- ple are more likelyto be permanentlyinjuredbyhot waterthan others.Theseincludethe elderly,children,theinfirm,or physical- lylmentally handicappedIf. anyoneusinghot water in your home fitsintooneofthesegroupsor ifthere isa localcodeor statelaw requiringa certaintemperaturewater at the hot water tap,then you musttake specialprecautionsIn. additionto usingthe lowest possibletemperaturesetting that satisfiesyour hot water needs, a meanssuchasa mixingvalve,shouldbe usedat the hot water

tapsusedby thesepeopleor at the water heater.Mixingvalves areavailableat plumbingsupplyor hardwarestore_Followman- ufacturers instructionsfor installation of the valves.Before

changingthe factory setting on the thermostat, read the "Temperature Regulation"sectioninthis manual.

AWARNING

Never allow small childrento usea hot water tap, or to draw

their own bathwater. Never leavea childor handicappedper- sonunattendedin a bathtub or shower.

The thermostat of this water heater has been factory set at its lowest position, to reduce the risk of scald injury. It is adiustable and must be reset to the desired temperature setting. The mark

(•)HOT indicative of approximately 120°F is the preferred

starting point. Some states have a requirement for a lower set- ting. If you need hotter water, follow directions for temperature adjustment, but beware of the warnings in this section.

Turn the water temperature dial clockwise Lff'_)

to decrease

the temperature, or counterclockwise (€" _) to increase the temperature.

PILOT

LIGHTING - Set here before lighting pilot.

HOT- Is a thermostat setting of approximately 120°F, which will supply hot water at the most economical temap,eratures.The tempera- ture adjustment knob can be turned lower than _HOT" if desired.

A - Is a thermostat setting of approximately 130°E

B -Is a thermostat setting of approximatey 140°E

C - ls a thermostat setting of approximately 150°E

VERY HOT - Is a thermostat setting of 160°E It is recom- mended that the dial be set lower whenever

possible.

NOTE: Water temperature range of 120°--140°Frecom- mended by most dishwasher manufacturers.

AWARNING1

Should overheatingoccur or the gassupplyfail to shut off,

I turn "OFF" the manualgascontrolvalveto the appliance. I

19

Image 19
Contents What to do if YOU Smell GAS AN Odorant is Added to the GAS Used by this Water HeaterArning Safety PrecautionsSerious Bodily INJURY,OR Property Damage Acaution AwarningContents Customer Responsibilities Product SpecificationsTubing Cutters or Hacksaw Materials and Basic Tools NeededMaterials Needed Basic ToolsRemoving the Old Water Heater Installation InstructionsWater passingouve Facts to Consider About Location Installation Instructions contdDEATH,SERIOUSBODILYINJUR,ORPROPERTYDAMAGE ALL AIR from Inside Buildings Hotterwater can SCALD.Water heatersam intendedto Installation Instructions contdInstallation Completed Using Sears Installation KIT Water PipingReliefvalveopening Temperature-Pressure Relief ValveISCREV¢DRAFTHOODI Filling the Water HeaterVenting Never usethis water heatunlessit mcompletelyfilledwithGas Piping Vent Pipe InstallationVenting contd Sediment Trap Installation InstructionsGAS Piping with Flexible Connector ContdBefore Lighting the Pilot Installation ChecklistContd Check for LeaksLighting Operating InstructionsBeforelighting PROPANEL.RGAS Water Heaters Force Operating Instructions contdWhattodo if Yousmellgas Not ForceOperating Instructions contd Temperature RegulationVenting System Inspection Service and AdjustmentTank Sediment Cleaning Burner CleaningService and Adjustment contd SMOKE/ODOR Troubleshooting GuideStart Up Conditions CondensationSmelly Water Troubleshooting Guide contdAIR in HOT Water Faucets Cold WateheatWater is TOO HOT High Temperature Shut OFF SystemOperational Conditions contd Not Enough or no HOT WaterLeakage Checkpoints Parts Order List Power Misertm 10 GAS Water HeatersModel Numbers Parts Order List contdWarranty

153.330401 specifications

The Kenmore 153.330401 is a highly regarded air conditioner that combines efficient cooling capabilities with user-friendly features, making it an ideal choice for homeowners seeking comfort during the heat of summer. This window-mounted air conditioning unit is designed to deliver powerful cooling while also minimizing energy consumption.

One of the standout features of the Kenmore 153.330401 is its impressive cooling capacity, measured at 10,000 BTU, which allows it to effectively cool spaces of up to approximately 450 square feet. This makes it suitable for medium to large rooms, such as living rooms, bedrooms, or even small office spaces. The air conditioner is equipped with multiple cooling settings, allowing users to tailor the cooling experience to their preferences.

The Kenmore 153.330401 also features an energy-saving mode that enhances its efficiency. This function helps to reduce electricity costs by automatically adjusting the cooling output based on the ambient temperature and the set preferences. The unit is ENERGY STAR certified, which ensures that it meets strict energy efficiency guidelines set by the Environmental Protection Agency.

Another notable technology integrated into the Kenmore 153.330401 is its quiet operation. This air conditioning unit is engineered to minimize noise during operation, ensuring a peaceful and comfortable environment, which is particularly valuable for bedrooms or quiet spaces. The unit also comes equipped with a remote control for added convenience, allowing users to adjust settings from across the room without having to get up.

The Kenmore 153.330401 includes adjustable air vents and a programmable timer, enabling users to set specific cooling schedules based on their daily routines. Additionally, the unit features a washable and reusable air filter, which helps to improve indoor air quality by trapping dust and allergens, and can be easily maintained for long-term performance.

In summary, the Kenmore 153.330401 air conditioner is a versatile and efficient cooling solution that offers robust performance, user-focused features, and energy-saving technologies. Whether for a living room, bedroom, or home office, this air conditioner provides a reliable option for maintaining a comfortable indoor environment during the hottest months of the year. Its combination of power, efficiency, and convenience makes it an excellent choice for any household.