._,WARNINGI

The water heater with draft hood installedmust be prep. [ erly vented to a chimney which termm.ates outdoors. I Never operate the water heater unlessit is vented to the outdoors and has adequate air supply.to avoid risks of

improper operation, explosionor asphyxiation.

AWARNING

Minimum clearancesbetween the water heater and com- bustibleconstruction are I" at the sidesand rear, 4" at the front, and 6" from the vent pipe. Clearance from the top of the jacket is 18" on most models. Note that a lesser dimension may be allowed on some models. Refer to the

label on the water heater adjacent to the gascontrol valve for all clearances.

. &WARNING[

Do not use this applianceif any part of.it has been under I water. Immediately call a Sears Service Technician to [ inspectthe applianceand to replace the gascontrol or any

part of the burner systemwhich hasbeen under water.

_,WARNING

HYDROGEN GAS: Hydrogen gascan be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive.To prevent the possi- bility of injury under these conditions,we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are

connectedto the hot water system are used(such as a dis- hwasher or washing machine). If hydrogen gas is present, there will probably he an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucnt at the time it is open.

a, WARNING

INSULATING JACKETS: When installing an external water heater insulationjacket on a gaswater heater:

DO NOT cover the temperature-pressure relief valve.

DO NOT put insulation over any part of the top of the gaswater heater,

DO NOT put insulation over the gascontrol valve or gas

control valve/burner cover, or any access areas to the burner.

DO NOT let insulation around the gas water heater to get within 8 inches of the floor (air must get to the burner).

DO NOT cover or remove operating instructions, and

safety related warning labelsand materials affixed to the water heater.

Failure to heed this will result in the possibilityof a fire or explosion.

ACAUTION.....

WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in sucha manner that if the tank or any connectionsshouldleak, the flow of water will not causedamage to the structure. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater, Drain pans are avail-

able at your local Sears store. Such a drain pan must be not greater than 1% inchesdeep, have a minimum length

and width of at least 2 Inches greater than the water heater dimensions and must be piped to an adequate drain. The pan must not restrict combustion air'flow, Under no circumstances is the manufacturer or Sears to

be held liable for any water damage in connection with this water heater,

4

Image 4
Contents AN Odorant is Added to the GAS Used by this Water Heater What to do if YOU Smell GASSafety Precautions ArningSerious Bodily INJURY,OR Property Damage Awarning AcautionContents Product Specifications Customer ResponsibilitiesMaterials and Basic Tools Needed Materials NeededBasic Tools Tubing Cutters or HacksawRemoving the Old Water Heater Installation InstructionsWater passingouve Facts to Consider About Location Installation Instructions contdDEATH,SERIOUSBODILYINJUR,ORPROPERTYDAMAGE ALL AIR from Inside Buildings Installation Instructions contd Installation Completed Using Sears Installation KITWater Piping Hotterwater can SCALD.Water heatersam intendedtoTemperature-Pressure Relief Valve ReliefvalveopeningFilling the Water Heater VentingNever usethis water heatunlessit mcompletelyfilledwith ISCREV¢DRAFTHOODIGas Piping Vent Pipe InstallationVenting contd Installation Instructions GAS Piping with Flexible ConnectorContd Sediment TrapInstallation Checklist ContdCheck for Leaks Before Lighting the PilotLighting Operating InstructionsBeforelighting PROPANEL.RGAS Water Heaters Operating Instructions contd Whattodo if YousmellgasNot Force ForceTemperature Regulation Operating Instructions contdService and Adjustment Tank Sediment CleaningBurner Cleaning Venting System InspectionService and Adjustment contd Troubleshooting Guide Start Up ConditionsCondensation SMOKE/ODORTroubleshooting Guide contd AIR in HOT Water FaucetsCold Wateheat Smelly WaterHigh Temperature Shut OFF System Operational Conditions contdNot Enough or no HOT Water Water is TOO HOTLeakage Checkpoints Power Misertm 10 GAS Water Heaters Parts Order ListParts Order List contd Model NumbersWarranty

153.330401 specifications

The Kenmore 153.330401 is a highly regarded air conditioner that combines efficient cooling capabilities with user-friendly features, making it an ideal choice for homeowners seeking comfort during the heat of summer. This window-mounted air conditioning unit is designed to deliver powerful cooling while also minimizing energy consumption.

One of the standout features of the Kenmore 153.330401 is its impressive cooling capacity, measured at 10,000 BTU, which allows it to effectively cool spaces of up to approximately 450 square feet. This makes it suitable for medium to large rooms, such as living rooms, bedrooms, or even small office spaces. The air conditioner is equipped with multiple cooling settings, allowing users to tailor the cooling experience to their preferences.

The Kenmore 153.330401 also features an energy-saving mode that enhances its efficiency. This function helps to reduce electricity costs by automatically adjusting the cooling output based on the ambient temperature and the set preferences. The unit is ENERGY STAR certified, which ensures that it meets strict energy efficiency guidelines set by the Environmental Protection Agency.

Another notable technology integrated into the Kenmore 153.330401 is its quiet operation. This air conditioning unit is engineered to minimize noise during operation, ensuring a peaceful and comfortable environment, which is particularly valuable for bedrooms or quiet spaces. The unit also comes equipped with a remote control for added convenience, allowing users to adjust settings from across the room without having to get up.

The Kenmore 153.330401 includes adjustable air vents and a programmable timer, enabling users to set specific cooling schedules based on their daily routines. Additionally, the unit features a washable and reusable air filter, which helps to improve indoor air quality by trapping dust and allergens, and can be easily maintained for long-term performance.

In summary, the Kenmore 153.330401 air conditioner is a versatile and efficient cooling solution that offers robust performance, user-focused features, and energy-saving technologies. Whether for a living room, bedroom, or home office, this air conditioner provides a reliable option for maintaining a comfortable indoor environment during the hottest months of the year. Its combination of power, efficiency, and convenience makes it an excellent choice for any household.