Kenmore 153.330401 owner manual Safety Precautions, Arning

Page 2

Safety Precautions

_W,.ARNING .

Impro.per installation, adjustment , alteration, service or maintenance can cause DEATH, SERIOUS BODILY

INJURY, OR PROPERTY DAMAGE. Refer to this manu- I al for assistance or consult your local Sears Service

[ Center for further information.

AWARNING

WATER HEATERS EQUIPPED FOR ONE TYPE GAS ONLY: This water heater is equipped for one type gas only. Check the model rating plate near the gas control

valve for the correct gas. DO NOT USE THIS WATER HEATER WITH ANY GAS OTHER THAN THE ONE

SHOWN QN THE MODEL RATING PLATE. Failure to usethe correct gascan causeproblem'swhich canresult in

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you have any questions or doubts consult your gassupplieror localutility.

AWARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ- UIDS (VAPORS) ARE LIKELY TO BE PRESENT OR

STORED (GARAGES, STORAGE, AND UTILITY AREAS, ETC): Flammable liquids (such as gasoline, solvents, propane (LP) or butane, etc.), all of which emit flammable vapors, may be improperly stored or used in such areas. The gas water heater pilot light or main burner can ignite such vapors. The resulting flashback and fire can cause death or serious burns to anyone in the area, as well as property damage.

If installation in such areas is your only option, then the

installation must be accomplishedin a way that the pilot flame and main burner flame are elevated from the floor

at least 18 inches. While this may reduce the chancesof flammable vapors from a floor spill being ignited, gasoline and other flammable substancesshouldnever be stored or used in the same room or area containing a gas water heater or other open flame or spark producingappliance. NOTE: Flammable vapors may be drawn by air currents from other areasof the structure to the appliance.

AWARNING

If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries

with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that com-

bustion and ventilation air be taken from outside these areas. Refer to the "Facts to Consider About the

Location" section of this manual and also the latest edi- tion of the National Fuel Gas Code, ANSI Z223.1, also

referred to as NFPA 54 for specificsprovided concerning air required.

_.WARNING

]

A fire can start if co_Hals

such as clothing,

cleaningmaterials, or flammable liquidsare placed against

or next to the water heater.

/

_,WARNING

At the time of manufacture this water heater was provid- ed with a combination temperature-pressures relief valve

certified by a nation.ally, recognized testing laboratory that maintains penodlc inspection of production of listed

equipment or materials, as meeting the requirements for

Relief Valves and Automatic Gas Shutoff Devicesfor Hot Water Supply Systems, and the latest edition of ANSI

Z21.22 and the code requirements of ASME. If replaced, the valve must meet the requirements of local codes,but not less than a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devicesfor Hot Water Supply Systems,ANSI Z21.22 by a nationally rec- ognized testing laboratory that maintains periodic

inspection of production of listed equipment or materials.

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 Ibs./sq. in.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3415 equal BTU/Hr. rate.)

Your local jurisdictional authority, while mandating the use of a temperature-prossure relief valve complying

with ANSI Z21.22 and ASME, may require a valve model different from the one furnished with the water heater.

Compliance with such local requirements must be satis- fied by the installer or end user of the water heater with a locally prescribed temperature-pressure relief valve installed in the designated opening in the water heater in place of the factory furnished valve.

For safe operation of the water heater, the relief valve must not b_ _OV---e'a'Trom_-'T_-'ed_g_aT_d_openingor plugged...........................

The temperature-pressure relief valve must be installed directly into_he_fieein_f_the-weterheater designatedfor the relief valve. Positionthe valve downward and provide tubing so that any dischal_e-WHT_it only within 6 inches above, or at any_dis.tancebe!ow the structural floor. Be certain that no contact is made with any live electrical part. The discharge.opening must not be blocked or reduced in size under any circumstances. Excessive length, over'30"feet,-oruse of more than four elbows can

cause restriction and reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between

the relief valve and the tank. Do not connect tubing directly to dischargedrain unlessa 6 air gap is provided.

To prevent bodily injury, hazard to life, or property dam- age, the relief valve must be allowed to dischargewater in quantities should circumstances demand• If the dis- charge pipe is not connected to a drain or other suitable means, the water flow may causeproperty damage.

The Discharge Pipe:

Must not be smaller in size than the outlet pipe size of

the valve, or have any reducing couplings or other restrictions.

Must not be pluggedor blocked.

Must be of material listed for hot water distribution. Must be installed so as to allow complete drainage of

both the temperature-pressure relief valve, and the dis- charge pipe.

Must terminate at an adequate drain.

Must not have any valve between the relief valve and tank.

Image 2
Contents AN Odorant is Added to the GAS Used by this Water Heater What to do if YOU Smell GASSafety Precautions ArningSerious Bodily INJURY,OR Property Damage Awarning AcautionContents Product Specifications Customer ResponsibilitiesBasic Tools Materials and Basic Tools NeededMaterials Needed Tubing Cutters or HacksawWater passingouve Installation InstructionsRemoving the Old Water Heater DEATH,SERIOUSBODILYINJUR,ORPROPERTYDAMAGE Installation Instructions contdFacts to Consider About Location ALL AIR from Inside Buildings Water Piping Installation Instructions contdInstallation Completed Using Sears Installation KIT Hotterwater can SCALD.Water heatersam intendedtoTemperature-Pressure Relief Valve ReliefvalveopeningNever usethis water heatunlessit mcompletelyfilledwith Filling the Water HeaterVenting ISCREV¢DRAFTHOODIVenting contd Vent Pipe InstallationGas Piping Contd Installation InstructionsGAS Piping with Flexible Connector Sediment TrapCheck for Leaks Installation ChecklistContd Before Lighting the PilotBeforelighting PROPANEL.RGAS Water Heaters Operating InstructionsLighting Not Force Operating Instructions contdWhattodo if Yousmellgas ForceTemperature Regulation Operating Instructions contdBurner Cleaning Service and AdjustmentTank Sediment Cleaning Venting System InspectionService and Adjustment contd Condensation Troubleshooting GuideStart Up Conditions SMOKE/ODORCold Wateheat Troubleshooting Guide contdAIR in HOT Water Faucets Smelly WaterNot Enough or no HOT Water High Temperature Shut OFF SystemOperational Conditions contd Water is TOO HOTLeakage Checkpoints Power Misertm 10 GAS Water Heaters Parts Order ListParts Order List contd Model NumbersWarranty

153.330401 specifications

The Kenmore 153.330401 is a highly regarded air conditioner that combines efficient cooling capabilities with user-friendly features, making it an ideal choice for homeowners seeking comfort during the heat of summer. This window-mounted air conditioning unit is designed to deliver powerful cooling while also minimizing energy consumption.

One of the standout features of the Kenmore 153.330401 is its impressive cooling capacity, measured at 10,000 BTU, which allows it to effectively cool spaces of up to approximately 450 square feet. This makes it suitable for medium to large rooms, such as living rooms, bedrooms, or even small office spaces. The air conditioner is equipped with multiple cooling settings, allowing users to tailor the cooling experience to their preferences.

The Kenmore 153.330401 also features an energy-saving mode that enhances its efficiency. This function helps to reduce electricity costs by automatically adjusting the cooling output based on the ambient temperature and the set preferences. The unit is ENERGY STAR certified, which ensures that it meets strict energy efficiency guidelines set by the Environmental Protection Agency.

Another notable technology integrated into the Kenmore 153.330401 is its quiet operation. This air conditioning unit is engineered to minimize noise during operation, ensuring a peaceful and comfortable environment, which is particularly valuable for bedrooms or quiet spaces. The unit also comes equipped with a remote control for added convenience, allowing users to adjust settings from across the room without having to get up.

The Kenmore 153.330401 includes adjustable air vents and a programmable timer, enabling users to set specific cooling schedules based on their daily routines. Additionally, the unit features a washable and reusable air filter, which helps to improve indoor air quality by trapping dust and allergens, and can be easily maintained for long-term performance.

In summary, the Kenmore 153.330401 air conditioner is a versatile and efficient cooling solution that offers robust performance, user-focused features, and energy-saving technologies. Whether for a living room, bedroom, or home office, this air conditioner provides a reliable option for maintaining a comfortable indoor environment during the hottest months of the year. Its combination of power, efficiency, and convenience makes it an excellent choice for any household.