23.Place screwdriver in slot “C”, see Figure 25. Depress and turn counterclockwise () to stop. Control screw must be in “IN” position for propane (LP) gas and in “OUT” position for natural gas. STOP! Read label “For Your Safety” located on your water heater.

FIGURE 25.

24.Light pilot following the lighting and operating instructions on the front surface of the heater.

25.Install outer door.

FUEL CONVERSION INSTRUCTIONS FROM PROPANE (L.P.) GAS TO NATURAL GAS

For conversion of Propane (LP) gas to Natural gas follow the “Fuel Conversion Instructions From Natural Gas to Propane (LP) Gas” except in:

1.Step 14, remove LP gas pilot assembly.

2.Step 16, remove LP gas burner head.

3.Step 17, use burner orifice marked “N”.

4.Step 18, use Natural gas burner head.

5.Step 20, use Natural gas pilot assembly.

6.Step 23, turn control screw in slot “C” in Figure 25 clockwise to stop. Screw must be in “OUT” position for Natural gas.

See “Instruction Label” for orifice sizes.

Maximum Supply Pressure: 10.5” W.C. for Natural Gas.

13” W.C. for Propane (L.P.) Gas.

Minimum Supply Pressure: 5” W.C. for Natural Gas.

11” W.C. for Propane (L.P.) Gas.

19

Image 19
Contents Economizer GAS Water Heater Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Table of Contents Preparing for the Installation Product SpecificationsCustomer Responsibilities Materials Needed Materials and Basic Tools NeededALL Piping Materials to be Supplied by Customers Install PERGET to Know Your Water Heater ReliefRemoving the OLD Water Heater Installation InstructionsHotter Water can Scald Typical InstallationsFacts to Consider about the Location Locating the NEW Water HeaterInsulation Blankets Securing Water Heater to Floor and Wall Water Piping Installing the NEW Water HeaterValve and Pipe Insulation Water Piping Pressure Test TEMPERATURE-PRESSURE Relief ValveOr Property Damage Filling the Water Heater Venting Draft Hood InstallationGAS Piping Alternative Sediment Trap Location Sediment TrapsPage Page Operating Instructions Before Lighting the Pilot Installation ChecklistSetting Temperature RegulationBurner Inspection Service and AdjustmentBurner Cleaning Venting System InspectionAnode ROD Inspection TEMPERATURE-PRESSURE Relief Valve OperationDraining Service Drain Valve Washer ReplacementStart UP Conditions Troubleshooting GuideCondensation Operational ConditionsLeakage Checkpoints Troubleshooting Guidelines Parts Order List Burner AssemblyPage Sears Installation Service Year Limited Warranty on Water HeaterYear Exclusive Kenmore Labor Warranty Warranty Service