Kenmore 153.33385 owner manual Installation Checklist, Before Lighting the Pilot

Page 21

INSTALLATION CHECKLIST

BEFORE LIGHTING THE PILOT:

1.Check the gas lines for leaks.

a.Use a soapy water solution. DO NOT test for gas leaks using a match or open flame.

b.Brush the soapy water solution on all gas pipes, joints and fittings.

c.Check for bubbling soap. This means you have leak. Turn “OFF” gas and make the necessary repairs.

2.Is the new temperature-pressure relief valve properly installed and piped to an adequate drain? See “Temperature-Pressure Relief Valve” section.

3.Are the cold and hot water lines connected to the water heater correctly? See “Water Piping” instructions in the “Installing the New Water Heater” section.

4.Is the water heater completely filled with water? See “Filling the Water Heater” instructions in the “Installing the New Water Heater” section.

5.Will a water leak damage anything? See the “Locating the New Water Heater” section.

6.Is there proper clearance between the water heater and anything that might catch fire? See the “FACTS TO CONSIDER ABOUT THE LOCATION” section.

7.Do you have adequate ventilation so that the water heater will operate properly? See the “FACTS TO CONSIDER ABOUT THE LOCATION” section.

8.Is the draft hood vent piping properly secured? See “Venting” instructions in the “Installing the New Water Heater” section.

9.Is there proper clearance between the vent pipe and anything that might catch on fire? See “Venting” Instructions in the “Installing the New Water Heater” section.

10.Is the vent pipe properly sloped and does the vent terminate outdoors? See “Venting” instructions in the “Installing the New Water Heater” section.

11.Do you need to call your gas company to check the gas pipe and its hookup?

21

Image 21
Contents Economizer GAS Water Heater Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Table of Contents Product Specifications Preparing for the InstallationCustomer Responsibilities Materials Needed Materials and Basic Tools NeededGET to Know Your Water Heater Install PERRelief ALL Piping Materials to be Supplied by CustomersRemoving the OLD Water Heater Installation InstructionsHotter Water can Scald Typical InstallationsFacts to Consider about the Location Locating the NEW Water HeaterInsulation Blankets Installing the NEW Water Heater Securing Water Heater to Floor and Wall Water PipingValve and Pipe Insulation TEMPERATURE-PRESSURE Relief Valve Water Piping Pressure TestOr Property Damage Filling the Water Heater Venting Draft Hood InstallationGAS Piping Alternative Sediment Trap Location Sediment TrapsPage Page Operating Instructions Before Lighting the Pilot Installation ChecklistSetting Temperature RegulationBurner Cleaning Service and AdjustmentVenting System Inspection Burner InspectionTEMPERATURE-PRESSURE Relief Valve Operation Anode ROD InspectionDraining Service Drain Valve Washer ReplacementStart UP Conditions Troubleshooting GuideCondensation Operational ConditionsLeakage Checkpoints Troubleshooting Guidelines Parts Order List Burner AssemblyPage Year Exclusive Kenmore Labor Warranty Year Limited Warranty on Water HeaterWarranty Service Sears Installation Service