Kenmore 153.33385 Service and Adjustment, Venting System Inspection, Burner Inspection

Page 23

SERVICE AND ADJUSTMENT

VENTING SYSTEM INSPECTION

At least once a year a visual inspection should be made of the venting system. You should look for:

1.Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed.

2.Damage or deterioration which could cause improper venting or leakage of combustion products.

3.Rusted flakes around top of water heater.

Be sure the vent piping is properly connected to prevent escape of dangerous flue gasses which could cause deadly asphyxiation.

Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

If after inspection of the vent system you found sooting or deterioration, something is wrong. Call the local gas utility to correct the problem and clean or replace the flue and venting before resuming operation of the water heater.

BURNER INSPECTION

Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a flooded water heater will create dangerous conditions which can cause

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

At least once a year a visual inspection should be made of the main burner and pilot burner, see Figure 27.

You should check for sooting. Soot is not normal and will impair proper combustion.

Soot build-up indicates a problem that requires correction before further use. Turn “OFF” gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fire causing death, serious injury, or property damage.

FIGURE 27.

BURNER CLEANING

In the event your burner needs cleaning, follow these instructions:

If inspection of the burner shows that cleaning is required, turn the gas control knob clockwise ( ) to the “OFF” position, depressing slightly.

NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly. DO NOT FORCE.

The burner needs to be removed for cleaning. Call a service agency to remove and clean the burner and correct the problem that required the burner to be cleaned.

HOUSEKEEPING

Vacuum around base of water heater for dust, dirt, and lint on a regular basis.

AT LEAST ONCE EVERY SIX MONTHS A VISUAL INSPECTION SHOULD BE MADE OF THE AIR INTAKE SCREEN. CLEAN IF LINT ACCUMULATIONS ARE NOTICED.

23

Image 23
Contents Economizer GAS Water Heater Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Table of Contents Customer Responsibilities Product SpecificationsPreparing for the Installation Materials Needed Materials and Basic Tools NeededALL Piping Materials to be Supplied by Customers Install PERGET to Know Your Water Heater ReliefRemoving the OLD Water Heater Installation InstructionsHotter Water can Scald Typical InstallationsFacts to Consider about the Location Locating the NEW Water HeaterInsulation Blankets Valve and Pipe Insulation Installing the NEW Water HeaterSecuring Water Heater to Floor and Wall Water Piping Or Property Damage TEMPERATURE-PRESSURE Relief ValveWater Piping Pressure Test Filling the Water Heater Venting Draft Hood InstallationGAS Piping Alternative Sediment Trap Location Sediment TrapsPage Page Operating Instructions Before Lighting the Pilot Installation ChecklistSetting Temperature RegulationBurner Inspection Service and AdjustmentBurner Cleaning Venting System InspectionDraining TEMPERATURE-PRESSURE Relief Valve OperationAnode ROD Inspection Service Drain Valve Washer ReplacementStart UP Conditions Troubleshooting GuideCondensation Operational ConditionsLeakage Checkpoints Troubleshooting Guidelines Parts Order List Burner AssemblyPage Sears Installation Service Year Limited Warranty on Water HeaterYear Exclusive Kenmore Labor Warranty Warranty Service