Kenmore 116.32289, 116.32189 owner manual An authorized service representative

Page 22

Review this chart to find do-it-yourself solutions for minor performance problems. Any ser- vice needed, other than those described in this owner's manual, should be performed by

an authorized service representative.

Cleaner won't run.

Poor job of dirt pick-upo

1.Unplugged at wall outlet

2.Tripped circuit breaker/blown fuse at household service panel,

3.ON/OFF switch not turned ON

1, Full or clogged dust bag

2.Wrong pile height setting

3.Worn agitator

4.Clogged nozzle or dirt tube

5.Clogged hose.

6, Hole in hose

7.Brokenfmisplaced belt

8.Hose not inserted fully

9,, Motor protection system activated, 10. Dirty filters

1o Plug in firmly, push ON/OFF switch tc ON,

2o Reset circuit breaker or replace fuse.

3, Push ONtOFF switch to ON

Change dust bag, (page I3).

2.Adjust setting, (page 7).

3, Replace agitalor, (page 21)

4o Clean nozzle area, (page 19). 5, Check for clogs, (page 19)

6.Replace hose..

7.Replaceffix belt, (page 17)

B_ Insert hose fully, (page !0). 9. Check for clogs, (page t9)

10. Clean filters, (pages 14-15)

Cleaner picks up moveable rugs or pushes too hard°

Light won'twork.

Agltator does not turn°

Performance indicator, some models, is red°

'I,,Wrong pile height setting

1, Burned out light bulb,

1.Broken bell

2.Bare floor seleclor in bare floor setting

3, Belt installed incorrectly

1. Full or clogged dust bag.

2o Dirty filters

3.Clogged airflow passage - dirt tube, nozzle, hose,

4.Certain attachment tools.

Adjust setting, (page 7).

1. Change light bulb, (page 20)

I.Replace belt, (page 16)

2.Switch selector to the carpet setting, (page 7)

3, Check BELT CHANGING AND AG]TATOR CLEANING, (page 17).

1.Change dust bag, (page 13)

2.Clean filters, (pages t4-15)

3.Clear clog from airflow passage, (page !9)_

4,, Should return to normal when tool is removed,

Air flow restricted

1.

Attachment

use restricts

with attachment

use,

 

air flow,

 

Sound changes,.

 

2.

New carpet

fuzz clogged air path

Excessive noise

as

1.

Belt rubbing on carpeL/bare floor

vacuum is shut

off.

 

selector shaft,

1.Check ATTACHMENTS, (page 8),,

2_ Check CLOG REMOVAL and clean hose, (page 19),

1, Push selector all the way forward

22

Image 22
Contents Manual Del Propietario Vacuum Cleaner Aspiradora Parts Before UsingLimited Oneyear Warranty on Kenmore Vacuum Cleaner Sears, Roebuck and Con, D/8t7 WA, Hoffman Estates, ILNot Put any objects Into U.S Canada Handle Assembly Do not overtightenInto QuickSuggested Pile Height Settings Some ModelsHandle Mounted Body MountedSlide To OperatesuctioncontrolTelescoping Wand To USE Extension Hose To Store AttachmentsDusting Brush Crevice Tool Fabric Trouble Performance IndicatorMotor Protection System ShootingCause personal injury or damage To Replace BAG ShootingTo REP LAC E BAG SafetyTo Remove BAG Electrical Shock HazardDo not operate without exhaust filter Exhaust PanelTo Remove Belt Heavy To Clean AgitatorTo Replace Belt ModerateIncorrect Routing of Belt Belt RoutingCorrect Routing of Belt Incorrect Routing Belt Selector Bare Floor PositionElectrical Shock Or Personal Injury Or cleaning UnitCleaner Disconnect Electrical SupplyHazard To Replace Agitator Agitator CleaningTo Check Agitator An authorized service representative Lnstrucciones Operacibn Antes de usar Su aspiradora nueva ,, tEstados Untdos Adverte CIA Objeto Pieza N Orificiopara \\ -.----MangoParte Det mangoLiberaci6n CintaSujetador de Cord6nSUGERENClAS DE Ajuste DE Nivel DE Para seleccionar un ajuste de ntvel de pelo de ia alfombraPelo Alfombra Accesorios Montado EN EL Iviango Montado EN EL CuerpoComo Utilizar LOS OFEDeslizador Papa Operar EL DESLIZA- DOR DE Control DEDe control Accesorio Manguera DE ExtensionAlmacenaje DE LOS Accesorios Peligro de choque elctrico o lesi6n cor Sistema DE Protection DE MiotorPara correglr el pro Peligro de choque elbctrico o lesi6n cor AsParae Para Quitar LA BolsaPara Cambiar LA Bolsa DelmotorDe la belsa Para Quitar LA BolsaPara Cambiar LA Bolsa Nunca Reutilice UNA BolsaPanel de Ranura deEscape Para Quitar LA Correa Del motor ImportantePara Caivibiar LA Correa \d Sprte El cepilloCorrea No Estd Centrada Correa Estd CentradaSobre la Ranura Guia Correa No Estd Centrada Sobre la Ranura GuiaEl plato de Peltgro de choque elctrico o lesi6n corLengietas de Para retirar dola y vaya danPara Quitar EL Agitador DEL AgitadorDe/a Correa Y Limpieza DEL AgitadorADVERTENClA Pe,grodechequeel ctrtco For repair Www, sears.com

116.32189, 116.32289 specifications

The Kenmore 116.32289 and Kenmore 116.32189 are part of Kenmore’s legacy of high-quality canister vacuums designed to deliver powerful cleaning performance while ensuring user-friendly operation. These models combine advanced technologies with practical features to cater to diverse cleaning needs in homes.

One of the main features of the Kenmore 116.32289 and 116.32189 is the powerful motor, which provides strong suction capability. This robust motor allows users to effectively clean various surfaces, from carpets to hard floors, making it suitable for multi-surface cleaning. The vacuums also boast multiple height adjustment settings, accommodating different carpet pile heights and ensuring an efficient clean on any surface.

Both models come equipped with a HEPA filtration system, which captures 99.97% of dust, allergens, and particles as small as 0.3 microns. This feature is particularly appealing for allergy sufferers, as it ensures that indoor air quality is improved during and after cleaning. The dust bag capacity is also noteworthy, allowing users to clean larger areas without the need for frequent bag changes.

The Kenmore 116.32289 and 116.32189 feature a range of attachments designed for versatile cleaning. These include a dusting brush, upholstery nozzle, and crevice tool, enabling users to tackle various cleaning tasks efficiently. The integrated wand provides extended reach, making it easier to clean high or hard-to-reach spaces such as ceilings, corners, and behind large furniture.

Another characteristic that enhances user convenience is the lightweight design of these canister vacuums. Weighing significantly less than traditional upright models, they are easy to maneuver and transport from room to room. The retractable cord adds to the ease of use, allowing for quick storage without tangling.

Additionally, both models have a sleek and modern design, complemented by user-friendly controls. The ability to easily switch between different cleaning modes and adjust suction power further enhances their appeal.

In conclusion, the Kenmore 116.32289 and 116.32189 vacuum cleaners excel in delivering powerful suction, effective filtration, and versatile functionality. With their combination of advanced technology, practical features, and user convenience, they stand out as reliable choices for anyone looking to maintain a clean and healthy living environment. These models truly embody Kenmore's dedication to quality and innovation in home cleaning solutions.