IMPORTANT SAFETY INSTRUCTIONS

The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.

PREVENT ACCIDENTS

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:

Be sure the electrical service is adequate for the model you have chosen.

If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a screen panel included, you may want to remove the screen completely before installation.

Be sure the air conditioner has been securely and correctly installed according to the separate installation instructions provided with this manual. Save this manual and installation instructions for

possible future use in removing or reinstalling this unit.

Use gloves when handling the air conditioner.

Be careful to avoid cuts from sharp metal fins on front and rear coils.

V.'_V_Vl-'1;t_llELECTRICAL[qINFORMATION

The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements.

Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.

Your air conditioner must be plugged into in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.

Do not run air conditioner with a protective covering. This could result in mechanical damage within the air conditioner.

Do not use an extension cord or an adapter plug.

_Avoid fire hazard or electric shock. Do not use an extension cord or an adapter plug. Do not remove any prong from the power cord.

prong Ground

3-prong

 

 

3-prong

 

I _

I

grounding

plug

I _\_

I

type wall

 

_._

 

receptacle

supply

 

 

 

cord

 

 

 

Reset_

 

 

 

ENERGY SAVING IDEAS

The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation.

Install the room air conditioner on the shady side of your home. A window that faces north is best because it is shaded most of the day.

Do not block air conditioner flow inside with blinds, curtains, or furniture, or outside with shrubs, enclosures, or other buildings.

Close the floor and wall registers and the fireplace damper so cool air does not escape up the chimney or into the duct work.

Keep blinds and drapes in other windows closed during the sunniest part of the day.

Clean the air filter as recommended in the MAINTENANCE section of this manual.

Proper insulation and weather stripping in your home will help keep warm air out and cool air in.

External house shading with trees, plants or awnings will help reduce the air conditioner's work load.

Operate heat producing appliances such as ranges, washers, dryers, and dishwashers during the coolest part of the day.

-3-

Image 3
Contents Room AIR Conditioner Acondicionador DE Aire DE Ventana Numbers TroubleshootingVVl-1tllELECTRICALqINFORMATION Important Safety InstructionsFor Your Safety Prevent AccidentsUsing Slit Do not Usean ExtensioncordRecommendedgroundingmethod QTY Installation RequirementsInstallation Hardware Electrical ServiceHOW to Install InstallationItemf Ill DrainageTFRONT Installation Removal from WindowTIF AIR Conditioner is Blocked by Storm Window Frame Compressor HOW and WHYNormal Sounds Capacity and Running TimePull Open / Push Close FeaturesUsing the AIR Conditioner Vent ControlControl Panel Remote Control SignalTemperature Setting LtimerTimer Remote ControlHOW to Insert Batteries Into Remote Control Temperature SettingHOW to Replace Front Grille AIR Filter CleaningHOW to Remove the Front AIR Conditioner CleaningBefore Calling for Service AIR Conditioner Turns on and OFF RapidlyCheck Then Disponible Contactando AL Servicio Sears AL 1-800-4-MY-HOME Requ ErimientosInformacion Electrica Importantes Instrucciones DE SeguridadPOR SU Seguridad Para Prevenir AccidentesUtilizando Ranura NOUSECABLEELECTRIC0DEEXTENSIONMitodorecomendadodeconexiona Tierra Utilizando LA Ranura BNombre DE LAS Piezas Cantidad Requerimientos Para InstalacionServicio Electrico Instalacion Piezas DE MontajeInterior InstalacionComo Instalarlo ITEM E FiguraIdreanje NotaFigura La ELIMINAClONDE la Ventana Instalacion FrontalCapacidad Y Tiempo DE Funcionamiento Como Y POR QUIControl DE Ventilacion CaractersticasDespliegue Marcador DE ENCENDIDO/APAGADO Control RemotoComo a Baterias DE Adicion EN EL Control Remoto Ajuste DE LA TemperaturaLimpieza DEL Filtro DEL Aire Limpieza DEL Equipo DE Aire AcondicionadoComo a Reemplaza EL Grille Anterior Detrasdelpaneldecorativofrontal Antes DE Llamar Para ServicioEL Equipo DE Aire Acondicionado no Funciona EL Aire DE LA Unidad no Sale Bastante FROPage 1291 30i Master Protection Agreements Sears.oom

580.75281 specifications

The Kenmore 580.75281 is a high-performance air purifier designed to enhance indoor air quality in homes and offices. With an emphasis on advanced filtration technologies, this model effectively captures a wide range of airborne pollutants, making it an ideal choice for individuals with allergies, asthma, or those simply seeking to breathe cleaner air.

One of the standout features of the Kenmore 580.75281 is its comprehensive four-stage filtration system. It includes a pre-filter designed to capture larger particles like dust, pet hair, and lint. This initial layer is crucial as it prevents these larger particles from clogging the more intricate filters that follow. This results in more efficient operation and longer filter life.

The True HEPA filter is the heart of the air purifier. Capable of capturing up to 99.97% of microscopic allergens down to 0.3 microns, this filter effectively reduces common irritants such as pollen, mold spores, smoke, and pet dander. By significantly reducing these harmful particles, the 580.75281 promotes healthier breathing conditions, particularly for those who suffer from seasonal allergies or respiratory issues.

In addition to the True HEPA filter, the Kenmore 580.75281 features an activated carbon filter that effectively absorbs odors and harmful gases. This is particularly beneficial in households where cooking smells, pet odors, or smoke can accumulate. The combination of HEPA and activated carbon filtration ensures that the air is not only free from allergens but also fresh and pleasant.

Another technological highlight is the air purifier’s Smart Sensor feature. This advanced system automatically monitors the air quality and adjusts the fan speed as needed. The LED indicator provides real-time feedback, allowing users to see how changes in the environment impact air quality. This not only optimizes performance but also enhances energy efficiency.

The Kenmore 580.75281 is also user-friendly, equipped with a simple control panel that allows users to select from multiple fan speeds. Additionally, the unit runs quietly, making it suitable for use in bedrooms and living spaces without disturbing daily activities or sleep.

With its robust build, sleek design, and effective multi-stage filtration system, the Kenmore 580.75281 proves to be an excellent investment for anyone looking to ensure cleaner, healthier indoor air. Whether for allergy relief or simply improving overall air quality, this air purifier delivers impressive results in a user-friendly package.