INSTALLATION

Pick a location which will allow you to blow the cold air into the area you want. Windows used for installation must be strong enough to support the weight of the air conditioner. Good installation with

special attention to the proper position of the unit will lessen the chance that service will be needed.

When cooling more than one room, installation

location is very important. To cool your rooms, cold air must be blown from the air conditioner in a

straight path.

Lastly it is adviced to save the shpping carton for future storage of the unit.

HOW TO INSTALL

If the air conditioner is blocked by a storm window frame, see step 16 on page 8 before beginning to install.

ORemove the screws which fasten the cabinet at the back and side of the unit. Save side screws.

Discard back screws.

FIG. 3

_ Slide the unit out of the cabinet by gripping the base pan handle and pull forward while bracing the cabinet.

FIG. 4

i_"_ Cut the FOAM SEAL (ITEM J) to fit the underside of the window sash. Peel off the backing and attach the FOAM SEAL as shown in Fig. 5.

..... Sash

FIG. 5

L_I Insert the side curtains (ITEM A) into the upper guide and lowerguide on each side of the air conditioner cabinet. Fasten the curtains to the unit with screws (ITEM E).

ITEM E

Lower Guide

ITEM E FIG, 6

_Open the window. Mark a line on the center of the

window inner sill. Loosely attach the sill bracket (ITEM C) to the support bracket (ITEM B) using the carriage bolt (ITEM I) and the lock nut (ITEM D).

ITEM

ITEM I

r'_ Attach the sill bracket to the window sill using the

screws (ITEM F). Carefully place the cabinet on the window inner sill and align the center of the cabinet front with the center line marked on the window inner sill.

 

/Machine

screw(ITEMH)

Cabinet_

/and locknut (ITEMD)

trackhole

_Outer

 

/edge

of

ITEM

windowsill

Carriagebolt................J

Sillbracket

FIG. 8

andlocknut

H Using the M-screw (ITEM H) and the lock nut

(ITEM D), attach the support bracket to the cabinet track hole. Use the first track hole as shown. Tighten the carriage bolt and the lock nut. Be sure the cabinet slants downward 1/4" from level.

CAUTION: Do not drill a hole in the base pan. The unit is designed to operate with approximately 1/2" of water in base pan.

Lowerguide

Cabinet

INDOOR

OUTDOOR

FIG. 9

-6-

Image 6
Contents Room AIR Conditioner Acondicionador DE Aire DE Ventana Troubleshooting NumbersPrevent Accidents Important Safety InstructionsFor Your Safety VVl-1tllELECTRICALqINFORMATIONUsing Slit Do not Usean ExtensioncordRecommendedgroundingmethod Electrical Service Installation RequirementsInstallation Hardware QTYInstallation HOW to InstallIll Drainage ItemfTFRONT Installation Removal from WindowTIF AIR Conditioner is Blocked by Storm Window Frame Capacity and Running Time HOW and WHYNormal Sounds CompressorVent Control FeaturesUsing the AIR Conditioner Pull Open / Push CloseLtimer Remote Control SignalTemperature Setting Control PanelTemperature Setting Remote ControlHOW to Insert Batteries Into Remote Control TimerAIR Conditioner Cleaning AIR Filter CleaningHOW to Remove the Front HOW to Replace Front GrilleBefore Calling for Service AIR Conditioner Turns on and OFF RapidlyCheck Then Requ Erimientos Disponible Contactando AL Servicio Sears AL 1-800-4-MY-HOMEPara Prevenir Accidentes Importantes Instrucciones DE SeguridadPOR SU Seguridad Informacion ElectricaUtilizando LA Ranura B NOUSECABLEELECTRIC0DEEXTENSIONMitodorecomendadodeconexiona Tierra Utilizando RanuraInstalacion Piezas DE Montaje Requerimientos Para InstalacionServicio Electrico Nombre DE LAS Piezas CantidadITEM E Figura InstalacionComo Instalarlo InteriorNota IdreanjeInstalacion Frontal Figura La ELIMINAClONDE la VentanaComo Y POR QUI Capacidad Y Tiempo DE FuncionamientoCaractersticas Control DE VentilacionDespliegue Ajuste DE LA Temperatura Control RemotoComo a Baterias DE Adicion EN EL Control Remoto Marcador DE ENCENDIDO/APAGADOLimpieza DEL Filtro DEL Aire Limpieza DEL Equipo DE Aire AcondicionadoComo a Reemplaza EL Grille Anterior EL Aire DE LA Unidad no Sale Bastante FRO Antes DE Llamar Para ServicioEL Equipo DE Aire Acondicionado no Funciona DetrasdelpaneldecorativofrontalPage 1291 30i Master Protection Agreements Sears.oom

580.75281 specifications

The Kenmore 580.75281 is a high-performance air purifier designed to enhance indoor air quality in homes and offices. With an emphasis on advanced filtration technologies, this model effectively captures a wide range of airborne pollutants, making it an ideal choice for individuals with allergies, asthma, or those simply seeking to breathe cleaner air.

One of the standout features of the Kenmore 580.75281 is its comprehensive four-stage filtration system. It includes a pre-filter designed to capture larger particles like dust, pet hair, and lint. This initial layer is crucial as it prevents these larger particles from clogging the more intricate filters that follow. This results in more efficient operation and longer filter life.

The True HEPA filter is the heart of the air purifier. Capable of capturing up to 99.97% of microscopic allergens down to 0.3 microns, this filter effectively reduces common irritants such as pollen, mold spores, smoke, and pet dander. By significantly reducing these harmful particles, the 580.75281 promotes healthier breathing conditions, particularly for those who suffer from seasonal allergies or respiratory issues.

In addition to the True HEPA filter, the Kenmore 580.75281 features an activated carbon filter that effectively absorbs odors and harmful gases. This is particularly beneficial in households where cooking smells, pet odors, or smoke can accumulate. The combination of HEPA and activated carbon filtration ensures that the air is not only free from allergens but also fresh and pleasant.

Another technological highlight is the air purifier’s Smart Sensor feature. This advanced system automatically monitors the air quality and adjusts the fan speed as needed. The LED indicator provides real-time feedback, allowing users to see how changes in the environment impact air quality. This not only optimizes performance but also enhances energy efficiency.

The Kenmore 580.75281 is also user-friendly, equipped with a simple control panel that allows users to select from multiple fan speeds. Additionally, the unit runs quietly, making it suitable for use in bedrooms and living spaces without disturbing daily activities or sleep.

With its robust build, sleek design, and effective multi-stage filtration system, the Kenmore 580.75281 proves to be an excellent investment for anyone looking to ensure cleaner, healthier indoor air. Whether for allergy relief or simply improving overall air quality, this air purifier delivers impressive results in a user-friendly package.