Kenmore 580.75281 Installation Requirements, Installation Hardware, Electrical Service, Qty

Page 5

INSTALLATION REQUIREMENTS

Your air conditioner will install into standard double

hung windows with actual clear opening widths of 29 to 41 inches (737mm to 1041mm) (FIG. 1)

Lower sash must open sufficiently to allow a clear

vertical opening of 19 inches (483mm). Side louvers and the rear of the air conditioner must have clear

air space to allow enough airflow through the condenser for heat removal. The rear of the unit must be outdoors, not inside a building or garage.

INSTALLATION HARDWARE

B C D E

F G H I J K

H..........Sash

. 29,,to4t,,-t/

19"min.

/

 

, . ,

Inner sillL

[

_

wlnaow

,',,2<>

 

_--Offset

,

 

 

 

si,

 

 

 

f"--,_; Exterior

/""J

"- ....

1/

FIG 1

Interior wall

"

 

ELECTRICAL SERVICE

Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on right side of cabinet).

All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the necessary corrections.

SAVE CARTON and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use.

To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit.

To prevent injury or strain, use proper lifting and carrying techniques when moving unit.

Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time.

Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils.

Make sure air conditioner does not fall during installation.

L

 

 

FIG. 2

ITEM

NAME OF PARTS

Q'TY

A

SIDE CURTAIN

2

B

SUPPORT BRACKET

2

C

SILL BRACKET

2

D

LOCK NUT

4

E

SCREW: 25/64"

11

F

SCREW: 13/16''

7

G

SCREW: 9/16"

5

H

M-SCREW

2

I

CARRIAGE BOLT

2

J

FOAM SEAL

1

K

FOAM STRIP

1

L

WINDOW LOCKING BRACKET

1

M

DRAIN PIPE

1

REQUIRED TOOLS:

Tight Fitting gloves

Standard screwdriver

Phillips screwdriver

Pliers

Sharp knife

3/8-inch open end wrench or adjustable wrench

1/4-inch hex socket and ratchet

Tape measure

Electric drill

1/4qnch drill bit

-5-

Image 5
Contents Room AIR Conditioner Acondicionador DE Aire DE Ventana Numbers TroubleshootingFor Your Safety Important Safety InstructionsPrevent Accidents VVl-1tllELECTRICALqINFORMATIONRecommendedgroundingmethod Using SlitDo not Usean Extensioncord Installation Hardware Installation RequirementsElectrical Service QTYHOW to Install InstallationItemf Ill DrainageTIF AIR Conditioner is Blocked by Storm Window Frame TFRONT InstallationRemoval from Window Normal Sounds HOW and WHYCapacity and Running Time CompressorUsing the AIR Conditioner FeaturesVent Control Pull Open / Push CloseTemperature Setting Remote Control SignalLtimer Control PanelHOW to Insert Batteries Into Remote Control Remote ControlTemperature Setting TimerHOW to Remove the Front AIR Filter CleaningAIR Conditioner Cleaning HOW to Replace Front GrilleCheck Then Before Calling for ServiceAIR Conditioner Turns on and OFF Rapidly Disponible Contactando AL Servicio Sears AL 1-800-4-MY-HOME Requ ErimientosPOR SU Seguridad Importantes Instrucciones DE SeguridadPara Prevenir Accidentes Informacion ElectricaMitodorecomendadodeconexiona Tierra NOUSECABLEELECTRIC0DEEXTENSIONUtilizando LA Ranura B Utilizando RanuraServicio Electrico Requerimientos Para InstalacionInstalacion Piezas DE Montaje Nombre DE LAS Piezas CantidadComo Instalarlo InstalacionITEM E Figura InteriorIdreanje NotaFigura La ELIMINAClONDE la Ventana Instalacion FrontalCapacidad Y Tiempo DE Funcionamiento Como Y POR QUIControl DE Ventilacion CaractersticasDespliegue Como a Baterias DE Adicion EN EL Control Remoto Control RemotoAjuste DE LA Temperatura Marcador DE ENCENDIDO/APAGADOComo a Reemplaza EL Grille Anterior Limpieza DEL Filtro DEL AireLimpieza DEL Equipo DE Aire Acondicionado EL Equipo DE Aire Acondicionado no Funciona Antes DE Llamar Para ServicioEL Aire DE LA Unidad no Sale Bastante FRO DetrasdelpaneldecorativofrontalPage 1291 30i Master Protection Agreements Sears.oom

580.75281 specifications

The Kenmore 580.75281 is a high-performance air purifier designed to enhance indoor air quality in homes and offices. With an emphasis on advanced filtration technologies, this model effectively captures a wide range of airborne pollutants, making it an ideal choice for individuals with allergies, asthma, or those simply seeking to breathe cleaner air.

One of the standout features of the Kenmore 580.75281 is its comprehensive four-stage filtration system. It includes a pre-filter designed to capture larger particles like dust, pet hair, and lint. This initial layer is crucial as it prevents these larger particles from clogging the more intricate filters that follow. This results in more efficient operation and longer filter life.

The True HEPA filter is the heart of the air purifier. Capable of capturing up to 99.97% of microscopic allergens down to 0.3 microns, this filter effectively reduces common irritants such as pollen, mold spores, smoke, and pet dander. By significantly reducing these harmful particles, the 580.75281 promotes healthier breathing conditions, particularly for those who suffer from seasonal allergies or respiratory issues.

In addition to the True HEPA filter, the Kenmore 580.75281 features an activated carbon filter that effectively absorbs odors and harmful gases. This is particularly beneficial in households where cooking smells, pet odors, or smoke can accumulate. The combination of HEPA and activated carbon filtration ensures that the air is not only free from allergens but also fresh and pleasant.

Another technological highlight is the air purifier’s Smart Sensor feature. This advanced system automatically monitors the air quality and adjusts the fan speed as needed. The LED indicator provides real-time feedback, allowing users to see how changes in the environment impact air quality. This not only optimizes performance but also enhances energy efficiency.

The Kenmore 580.75281 is also user-friendly, equipped with a simple control panel that allows users to select from multiple fan speeds. Additionally, the unit runs quietly, making it suitable for use in bedrooms and living spaces without disturbing daily activities or sleep.

With its robust build, sleek design, and effective multi-stage filtration system, the Kenmore 580.75281 proves to be an excellent investment for anyone looking to ensure cleaner, healthier indoor air. Whether for allergy relief or simply improving overall air quality, this air purifier delivers impressive results in a user-friendly package.