5.1Specifications

FOR HVAC INSTALLER ONLY

5.(DEH 2000) DIGITAL CONTROL Installation Instructions

Figure 5:

5.1Specifications

Model: 4024539

Electrical: 24 VAC

Humidity Range: 20 – 90%

RH Humidity Accuracy: +/- 4%

Output: 3 Amps 24 VAC

5.2Installation

This control panel must be installed in the conditioned space and in accordance with all applicable codes and standards. Follow the instructions below when installing and setting this control.

5.2A Install Instructions

1.Separate the front panel from the back panel by depressing the tongue located in the bottom of the control.

Figure 6:

2.Gently disconnect the quick connector on the back panel

3.Remove the battery from the back panel by sliding it to the left and out from it’s retaining clip. To mount in the black battery holder on the front panel, insert it from the top, gently pressing downward until it snaps into place and is held under the top clip of the holder. The + engraved on the battery should be visible.

4.Line the back panel up against the wall or flat surface onto which it is to be mounted and drill in the appropriate mounting holes

5.Insert the screws so they extend approximately 1/8" from the wall or flat surface.

6.Align the back panel against these screws, pushing it forward, allowing it to slide downward to lock into position.

7.Make the electrical connections to the terminals on theback panel as shown in the wiring diagram.

8.Seal the hole around the wires to prevent air movement.

9.Reconnect the quick connector onto the back panel.

10.Reassemble the front to the back panel. Connect at the top first, then at the bottom.

5.2B Wiring

5.2InstallationWARNING

Warning: Do not allow the yellow lead from the Ultra-Aire to contact the red lead or orange lead from the Ultra-Aire or damage to the transformer will result.

The installer must supply the wiring between the Ultra-Aire and the control panel. Be sure to safely route the control wires to prevent damage during installation. Be careful not to cross wires when connecting the Ultra-Aire and the remote control panel or damage to the transformer may result.

5.2A Install Instructions IMPORTANT

The remote controls of the Ultra-Aire are powered by a low voltage circuit (24 VAC) and must NEVER contact or be connected to a high voltage circuit.

Some of the control wires may not be used with certain control panels and should be left safely disconnected with wire nuts taped onto the stripped ends. Be

sure to consult the electrical schematic in this manual

before making the control connections.

Figure 7:

11

Ultra-Aire 150H Installer’s & Owner’s Manual

Image 11
Contents Dehumidification HVAC INSTALLER PLEASE LEAVE MANUAL FOR HOMEOWNERUltra-Aire150H Whole House Ventilating DehumidifierTable of Contents TABLE OF CONTENTSREAD AND SAVE THESE INSTRUCTIONS SAFETY PRECAUTIONS1. Safety Precautions 1. Intended Application for Ultra-Aire150H FOR HVAC INSTALLER ONLY2. Specifications 3. Installation3.4B Ducting for Dehumidification FOR HVAC INSTALLER ONLY3.4 Ducting 3.4A Installing Duct Collars 3.3 Condensate Removal3.4C Ducting for Fresh Air FOR HVAC INSTALLER ONLY4.1 Humidity/Fan Control Panel FOR HVAC INSTALLER ONLY3.5 Quiet Installation 4. Controls4.4 Fan/Filter Switch FOR HVAC INSTALLER ONLY4.2Ventilation Timer and Humidity Control Panel 4.3 Humidity Control Adjustment4.6 Low Pressure Control FOR HVAC INSTALLER ONLYATTENTION INSTALLER 5.2A Install Instructions FOR HVAC INSTALLER ONLY5.1Specifications 5.2Installation5.3D Setting Clock Time FOR HVAC INSTALLER AND HOMEOWNER5.3B Setting 5.3C On/Off Setting5.3H Damper Operation and Setting Ventilation FOR HVAC INSTALLER ONLY AND HOMEOWNER5.3E Setting Relative Humidity Set point 5.3F Fan Setting and Operation5.3M Low Pressure Control FOR HVAC INSTALLER ONLY AND HOMEOWNER5.3J Programming Notes 5.3L Stop Start7.1 Warranty FOR HVAC INSTALLER ONLY6. Maintenance 7. Service7.3 Troubleshooting FOR HVAC INSTALLER ONLY7.4 Refrigerant Charging FOR HVAC INSTALLER ONLY7.6Compressor/Capacitor Replacement 7.5 Impeller Fan Replacement7.6C Replacing a Compressor, Nonburn Out FOR HVAC INSTALLER ONLY7.7 Remote Controls 7.7B Programmable Ventilation Timer7.11 Condensate Pump Kit FOR HVAC INSTALLER ONLYElectric Schematics of the UA-150H 7.10 Low Pressure ControlPictorial Electrical Diagrams of UA-150H FOR HVAC INSTALLER ONLYWiring Diagrams FOR HVAC INSTALLER ONLYThe UA-150H SERVICE PARTS LIST UA-150HAccessories OPTIONAL PARTS LIST UA-150HVIBRATION ISOLATION KIT UA-150H THE INSULATION TO THE UA-150H EXTERNAL INSULATION KIT UA-150HINSTRUCTIONS FOR APPLYING ATTENTION INSTALLER WARRANTOR ULTRA-AIRE150H Dehumidifier Limited WarrantyPhone: 608-222-5301 Fax PO Box 8680 Madison, WI