FOR HVAC INSTALLER ONLY
1. Intended Application for Ultra-Aire 150H
For the ideal installation, draw air from the central part of the home and return it to isolated areas of the home like the bedrooms, den, utility room, or family room. The ductwork of the existing heating system can be used to supply air to the home.
2. Specifications
Model: | ||||||
Electrical: |
|
| ||||
| grounded |
|
|
|
| |
Capacity: | 145 pints/day @ 80°F, 60% RH |
| ||||
Operating Temp. Range: | 56°F min., 100°F max. |
|
| |||
Air Flow: | 400 CFM without external ducting | |||||
| 355 CFM @ .20 IWG external static | |||||
| 290 CFM @ .40 IWG external static | |||||
Refrigerant Charge: | 2 lb., 2 oz. |
|
|
|
| |
Duct connections: | Round 10" & 6" inlets, 10" outlet | |||||
Filter Size: Pleated cloth: | 2" X 20" X 24" High Efficiency: 4" X 20" | |||||
X 24" | 45 / " long x 24 |
| / " wide x 20 |
| / " high | |
Size (w/o duct collars): |
|
| ||||
| 3 | 4 | 3 | 4 | 1 | 2 |
Unit Weight: | 145 lb., Shipping Weight 229 lb. |
3. Installation
3.1 Location
The
•It is designed to be installed INDOORS IN A SPACE THAT IS PROTECTED FROM RAIN AND FLOODING.
•Install the unit with space to access the front panel for maintenance and service. Also allow easy access to the filter cover panel. DO NOT INSTALL UNIT WITH THE FRONT PANEL OR FILTER COVER PANEL INACCESSIBLE.
•Avoid discharging the air directly at people, or over the water in pool areas.
•If used near a pool or spa, be certain there is NO chance the unit could fall into the water or be splashed and that it is plugged into a
GROUND FAULT INTERRUPTER.
•DO NOT use the
•DO NOT place the
•A drain pan MUST be placed under the unit if installed above a living area or above an area where water leakage could cause damage.
Place the
The
The
An external insulation kit is available for the
If fresh air ventilation is desired, thought should be given to the location for the fresh air ducting. A 6” round insulated duct will have to be installed on the
3.2 Electrical Requirements
WARNING: DO NOT ALLOW THE YELLOW LEAD FROM THE
The
20 Amp circuit. It draws around 12 Amps under normal operating conditions. If used in a wet area (pool, spa room, or basement prone to flooding), a ground fault interrupter protected circuit is required.
Install the remote control panel in a central area of the structure where it will sense the relative humidity of the structure accurately. Do not install the control panel where it may not accurately sense the relative humidity such as near HVAC supply registers, near exterior doors, or near a pool or spa. The installer must supply the wiring between the
4 |