Burnham 81441001R8-3/06 installation instructions Base-RayAssembly Chart

Page 4

Dimensions and Specifications

BASE-RAY TAPPINGS- Tapped 3/4" top and bot- tom of end sections. A 3/4" x 1/8" vent bushing is furnished with each Base-Ray Assembly. Only one air vent location need be used.

Use of PTFE (TeÀon®) tape or paste containing PTFE is not recommended as overtightening is possible, causing cracking of the Base Ray tappings.

Copper tubing is not recommended for steam appli- cations due to high heat loss through the tubing and thermal expansion noise.

Maximum recommended length for steam applications is 10 lineal feet.

Base-Ray®Assembly Chart

BASE-RAY Assemblies up to and including 6 lineal ft. are shipped in one piece.

Longer Assemblies are shipped in two or more pieces or sub- assemblies, none of which exceeds 6 lineal ft.

ASSEMBLIES AND SUB-ASSEMBLIES ARE MADE

UP OF FOLLOWING SECTIONS

 

18"

24"

 

24"

12"

18"

24"

ASSEMBLIES

Left

Left 24" Int.

Right

Right

Panel

Panel

 

End

End

 

End

End

 

 

1½ Ft. Assembly

---

---

---

---

---

1

---

 

 

 

 

 

 

 

 

2 Ft. Assembly

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

2½ Ft. Assembly

1

---

---

---

1

---

---

 

 

 

 

 

 

 

 

3 Ft. Assembly

---

1

---

---

1

---

---

 

 

 

 

 

 

 

 

3½ Ft. Assembly

1

---

---

1

---

---

---

 

 

 

 

 

 

 

 

4 Ft. Assembly

---

1

---

1

---

---

---

 

 

 

 

 

 

 

 

4½ Ft. Assembly

1

---

1

---

1

---

---

 

 

 

 

 

 

 

 

5 Ft. Assembly

---

1

1

---

1

---

---

 

 

 

 

 

 

 

 

5½ Ft. Assembly

1

---

1

1

---

---

---

6 Ft. Assembly

---

1

1

1

---

---

---

 

 

 

 

 

 

 

SUB-ASSEMBLIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5½ Ft. L.H.

1

---

2

---

---

---

---

Sub-Assy.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 Ft. L.H.

---

1

2

---

---

---

---

Sub-Assy.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 Ft. Center

---

---

3

---

---

---

---

Sub-Assy.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All R.H.

---

---

Required

1 or 1

---

---

Sub-Assy.

Number

 

 

 

 

 

 

Sub-Assembly Chart

ASSEMBLY

L.H.

CENTER

R.H.

LENGTH

 

 

 

 

 

 

 

 

 

6½ Ft.

5½ Ft.

---

1 Ft.

 

 

 

 

 

7 Ft.

6

Ft.

---

1 Ft.

 

 

 

 

 

7½ Ft.

5½ Ft.

---

2

Ft.

 

 

 

 

 

 

8 Ft.

6

Ft.

---

2

Ft.

 

 

 

 

 

8½ Ft.

5½ Ft.

---

3

Ft.

 

 

 

 

 

 

9 Ft.

6

Ft.

---

3

Ft.

 

 

 

 

 

9½ Ft.

5½ Ft.

---

4

Ft.

 

 

 

 

 

 

 

10

Ft.

6

Ft.

---

4

Ft.

 

 

 

 

 

10½ Ft.

5½ Ft.

---

5

Ft.

 

 

 

 

 

 

 

11

Ft.

6

Ft.

---

5

Ft.

 

 

 

 

 

11½ Ft.

5½ Ft.

---

6

Ft.

 

 

 

 

 

 

 

12

Ft.

6

Ft.

---

6

Ft.

 

 

 

 

12½ Ft.

5½ Ft.

6 Ft.

1 Ft.

 

 

 

 

 

 

13

Ft.

6

Ft.

6 Ft.

1 Ft.

 

 

 

 

13½ Ft.

5½ Ft.

6 Ft.

2 Ft.

 

 

 

 

 

 

 

14

Ft.

6

Ft.

6 Ft.

2

Ft.

 

 

 

 

14½ Ft.

5½ Ft.

6 Ft.

3 Ft.

 

 

 

 

 

 

 

15

Ft.

6

Ft.

6 Ft.

3

Ft.

 

 

 

 

15½ Ft.

5½ Ft.

6 Ft.

4 Ft.

 

 

 

 

 

 

 

16

Ft.

6

Ft.

6 Ft.

4

Ft.

 

 

 

 

16½ Ft.

5½ Ft.

6 Ft.

5 Ft.

 

 

 

 

 

 

 

17

Ft.

6

Ft.

6 Ft.

5

Ft.

 

 

 

 

17½ Ft.

5½ Ft.

6 Ft.

6 Ft.

 

 

 

 

 

 

 

18

Ft.

6

Ft.

6 Ft.

6

Ft.

 

 

 

 

18½ Ft.

5½ Ft.

2-6 Ft.

1 Ft.

 

 

 

 

 

 

19

Ft.

6

Ft.

2-6 Ft.

1 Ft.

 

 

 

 

 

19½ Ft.

5½ Ft.

2-6 Ft.

2

Ft.

 

 

 

 

 

 

 

20

Ft.

6

Ft.

2-6 Ft.

2

Ft.

 

 

 

 

 

20½ Ft.

5½ Ft.

2-6 Ft.

3

Ft.

 

 

 

 

 

 

 

21

Ft.

6

Ft.

2-6 Ft.

3

Ft.

 

 

 

 

 

21½ Ft.

5½ Ft.

2-6 Ft.

4

Ft.

 

 

 

 

 

 

 

22

Ft.

6

Ft.

2-6 Ft.

4

Ft.

 

 

 

 

 

22½ Ft.

5½ Ft.

2-6 Ft.

5

Ft.

 

 

 

 

 

 

 

23

Ft.

6

Ft.

2-6 Ft.

5

Ft.

 

 

 

 

 

23½ Ft.

5½ Ft.

2-6 Ft.

6

Ft.

 

 

 

 

 

 

 

24

Ft.

6

Ft.

2-6 Ft.

6

Ft.

4

Image 4
Contents Burnham BASE-RAY HOT Water Ratings in BTU PER Hour AT 2000 LBS./HR. Four G.P.M. Flow Rate Base-RayAssembly Chart Types of Systems BASE-RAYHYDRONICSSystem Description Installation Data Series Loop SystemsTo Design Series-Loop Base-RayInstallation Table a Table BMaximum Dimensions of Fittings Location of BASE-RAYRecessed ExpansionInstallation Instructions Wall PreparationAllowance for Finished Flooring to Wall-to-Wall Carpeting Recessing of BASE-RAY Assemblies and TrimInstallation of BASE-RAYAssemblies Assembling BASE-RAYPage Installation of Corner Plates Adjustable END Caps & Filler Pieces Completing Installation ImportantSpecial Applications BASE-RAYINSTALLEDONTHREEWALLSOFROOM Page Limited Warranty

81441001R8-3/06 specifications

The Burnham 81441001R8-3/06 is a state-of-the-art boiler designed to provide efficiency and reliability for residential and commercial heating systems. This model stands out due to its commitment to innovation and advanced engineering, making it a top choice for those seeking optimal heating performance.

One of the primary features of the Burnham 81441001R8-3/06 is its high efficiency rating. It is designed to convert fuel into heat with minimal wastage, ensuring that users receive more heat per unit of fuel consumed. This efficiency translates into lower operating costs and a reduced environmental footprint, making it an eco-friendly alternative in the world of heating solutions.

In terms of technology, the Burnham 81441001R8-3/06 is equipped with a robust, cast-iron heat exchanger. This component is crucial for transferring heat effectively while maintaining durability over time. Cast iron is known for its excellent heat retention properties and ability to withstand extreme temperatures, ensuring a longer lifespan for the boiler.

The model also features a user-friendly digital control system that allows for easy operation and monitoring. Homeowners can adjust settings, check system performance, and receive alerts when maintenance is required, leading to prolonged efficiency and safety. The boiler’s compatibility with smart home systems enhances convenience, allowing users to manage heating remotely via smartphones or tablets.

Another characteristic of the Burnham 81441001R8-3/06 is its compact design. This feature makes it ideal for installations in tight spaces without compromising on performance. The unit can fit comfortably in basements, utility rooms, or other restricted areas while delivering powerful heating service.

Moreover, safety is a top priority in the design of the Burnham 81441001R8-3/06. It includes multiple safety features such as pressure relief valves and electronic ignition systems that reduce the risk of accidents. These measures provide peace of mind for homeowners and ensure that the boiler operates safely throughout its lifespan.

In conclusion, the Burnham 81441001R8-3/06 boiler combines high efficiency, durable construction, advanced technology, and safety features, making it a leading choice for those in the market for reliable heating solutions. Whether for residential or commercial applications, it effectively meets the diverse heating needs of users, providing comfort and efficiency for years to come.