Burnham 81441001R8-3/06 Base-Rayhydronics, Types of Systems, System Description

Page 5

BASE-RAY®HYDRONICS

Types of Systems

Hydronic Heating Systems are classi¿ed according to the pip- ing arrangement and heating medium employed. BASE-RAY is very versatile in that it may be used in almost all types of systems as noted below:

1.Series Loop Forced Circulation Hot Water

2.One-Pipe Forced Circulation Hot Water

3.Two-Pipe Reverse Return Gravity or Forced Circulation Hot Water

4.Two-Pipe Steam or Vapor.

It is not recommended that BASE-RAY be used in a One-Pipe Steam System.

System Description

1.Series Loop is a forced circulation hot water heating system with the BASE-RAY Assemblies connected so that all the water Àowing through a circuit passes through each series- connected Assembly in the circuit. Thus, the Assemblies serve as portions of the main.

2.One-Pipeis a forced circulation hot water heating system utilizing one continuous main from boiler supply to boiler return. BASE-RAY Assemblies are connected to this pipe or main by two smaller pipes known as branches. When connecting these branches to the main, one of the standard

tees is replaced by a special tee frequently called a one-pipe ¿tting. These one-pipe ¿ttings cause a portion of the water Àowing through the main to pass through the BASE-RAY Assemblies and back to the main again.

3.Two-Pipe Reverse Return is a gravity or forced circulation hot water heating system utilizing one main to carry heated water from the boiler to the BASE-RAY Assemblies and a second main to carry the cooled water from the Assemblies back to the boiler. The Assemblies are connected to the return main in the reverse order from that in which they are connected to the supply main. Very few designers use this type of system for residential applications, since there is no difference between the heating qualities of this system and the other two hot water systems.

4.Two-Pipe Steam or Vapor Systems are steam systems in which each BASE-RAY Assembly is provided with two piping connections, and where steam and condensate Àow in separate mains and branches. The Vapor system differs from the low pressure system only in the type of air valve used.

5

Image 5
Contents Burnham BASE-RAY HOT Water Ratings in BTU PER Hour AT 2000 LBS./HR. Four G.P.M. Flow Rate Base-RayAssembly Chart System Description BASE-RAYHYDRONICSTypes of Systems Series Loop Systems Installation DataTable a Table B To Design Series-Loop Base-RayInstallationLocation of BASE-RAY Maximum Dimensions of FittingsRecessed ExpansionWall Preparation Installation InstructionsAllowance for Finished Flooring to Wall-to-Wall Carpeting Recessing of BASE-RAY Assemblies and TrimAssembling BASE-RAY Installation of BASE-RAYAssembliesPage Installation of Corner Plates Completing Installation Important Adjustable END Caps & Filler PiecesSpecial Applications BASE-RAYINSTALLEDONTHREEWALLSOFROOM Page Limited Warranty

81441001R8-3/06 specifications

The Burnham 81441001R8-3/06 is a state-of-the-art boiler designed to provide efficiency and reliability for residential and commercial heating systems. This model stands out due to its commitment to innovation and advanced engineering, making it a top choice for those seeking optimal heating performance.

One of the primary features of the Burnham 81441001R8-3/06 is its high efficiency rating. It is designed to convert fuel into heat with minimal wastage, ensuring that users receive more heat per unit of fuel consumed. This efficiency translates into lower operating costs and a reduced environmental footprint, making it an eco-friendly alternative in the world of heating solutions.

In terms of technology, the Burnham 81441001R8-3/06 is equipped with a robust, cast-iron heat exchanger. This component is crucial for transferring heat effectively while maintaining durability over time. Cast iron is known for its excellent heat retention properties and ability to withstand extreme temperatures, ensuring a longer lifespan for the boiler.

The model also features a user-friendly digital control system that allows for easy operation and monitoring. Homeowners can adjust settings, check system performance, and receive alerts when maintenance is required, leading to prolonged efficiency and safety. The boiler’s compatibility with smart home systems enhances convenience, allowing users to manage heating remotely via smartphones or tablets.

Another characteristic of the Burnham 81441001R8-3/06 is its compact design. This feature makes it ideal for installations in tight spaces without compromising on performance. The unit can fit comfortably in basements, utility rooms, or other restricted areas while delivering powerful heating service.

Moreover, safety is a top priority in the design of the Burnham 81441001R8-3/06. It includes multiple safety features such as pressure relief valves and electronic ignition systems that reduce the risk of accidents. These measures provide peace of mind for homeowners and ensure that the boiler operates safely throughout its lifespan.

In conclusion, the Burnham 81441001R8-3/06 boiler combines high efficiency, durable construction, advanced technology, and safety features, making it a leading choice for those in the market for reliable heating solutions. Whether for residential or commercial applications, it effectively meets the diverse heating needs of users, providing comfort and efficiency for years to come.