Burnham 81441001R8-3/06 installation instructions Installation Instructions, Wall Preparation

Page 9

INSTALLATION INSTRUCTIONS

1.Wall Preparation:

To prevent excessive heat loss through the walls in back of BASE-RAY®, it is recommended that the stud space behind the Assemblies be insulated to a height of at least 12” above the Àoor with 4” mineral wool batts (blanket or loose insulation may also be used) or other approved insulating materials. This is particularly essential if the BASE-RAY is recessed. Mark Stud locations.

2.Allowance for Finished Flooring to Wall-to-Wall Carpeting:

If BASE-RAY is to be installed prior to the ¿nished Àoor, a wooden strip 2½” in width and equal in height to the ¿nished Àoor should be installed along the base of all walls where baseboard assemblies and trim are to be placed.

If allowance is not made for wall-to-wall carpeting, or for carpeting that is to be laid with edges Àush to the room side surface of BASE-RAY, the air inlet of the BASE- RAY will be restricted, resulting in a reduction in output. To compensate for the wall-to-wall carpeting, baseboard assemblies and trim should be raised by laying under them a strip of wood 2½” wide and the same thickness as the carpet and pad.

3.Recessing of BASE-RAY Assemblies and Trim.

(If BASE-RAY to be installed free-standing, proceed to Step 4.)

BASE-RAYandTrimmaybepartiallyrecessedorinstalled free standing against the ¿nished wall surface. Although procedure for preparing recess may vary slightly with type of ¿nished wall, in general, steps outlined below for lath and plaster construction may be followed:

a.Nail ½” plaster ground to studs with the bottom of the plaster ground located 10” above ¿nished Àoor.

*Additional height must be allowed if recess prepared before ¿nished Àoor is laid or if wall-to- wall carpeting is to be installed – see Step 2 of Installation Instructions.

b.Line back of recess with paper-backed aluminum foil. This can be accomplished quickly and neatly by stapling foil to studs with staple gun. Foil surface should be on room side.

4.Locate Holes for Piping (see Illustrations):

9

Image 9
Contents Burnham BASE-RAY HOT Water Ratings in BTU PER Hour AT 2000 LBS./HR. Four G.P.M. Flow Rate Base-RayAssembly Chart BASE-RAYHYDRONICS Types of SystemsSystem Description Series Loop Systems Installation DataTable a Table B To Design Series-Loop Base-RayInstallationLocation of BASE-RAY Maximum Dimensions of FittingsRecessed ExpansionWall Preparation Installation InstructionsAllowance for Finished Flooring to Wall-to-Wall Carpeting Recessing of BASE-RAY Assemblies and TrimAssembling BASE-RAY Installation of BASE-RAYAssembliesPage Installation of Corner Plates Completing Installation Important Adjustable END Caps & Filler PiecesSpecial Applications BASE-RAYINSTALLEDONTHREEWALLSOFROOM Page Limited Warranty

81441001R8-3/06 specifications

The Burnham 81441001R8-3/06 is a state-of-the-art boiler designed to provide efficiency and reliability for residential and commercial heating systems. This model stands out due to its commitment to innovation and advanced engineering, making it a top choice for those seeking optimal heating performance.

One of the primary features of the Burnham 81441001R8-3/06 is its high efficiency rating. It is designed to convert fuel into heat with minimal wastage, ensuring that users receive more heat per unit of fuel consumed. This efficiency translates into lower operating costs and a reduced environmental footprint, making it an eco-friendly alternative in the world of heating solutions.

In terms of technology, the Burnham 81441001R8-3/06 is equipped with a robust, cast-iron heat exchanger. This component is crucial for transferring heat effectively while maintaining durability over time. Cast iron is known for its excellent heat retention properties and ability to withstand extreme temperatures, ensuring a longer lifespan for the boiler.

The model also features a user-friendly digital control system that allows for easy operation and monitoring. Homeowners can adjust settings, check system performance, and receive alerts when maintenance is required, leading to prolonged efficiency and safety. The boiler’s compatibility with smart home systems enhances convenience, allowing users to manage heating remotely via smartphones or tablets.

Another characteristic of the Burnham 81441001R8-3/06 is its compact design. This feature makes it ideal for installations in tight spaces without compromising on performance. The unit can fit comfortably in basements, utility rooms, or other restricted areas while delivering powerful heating service.

Moreover, safety is a top priority in the design of the Burnham 81441001R8-3/06. It includes multiple safety features such as pressure relief valves and electronic ignition systems that reduce the risk of accidents. These measures provide peace of mind for homeowners and ensure that the boiler operates safely throughout its lifespan.

In conclusion, the Burnham 81441001R8-3/06 boiler combines high efficiency, durable construction, advanced technology, and safety features, making it a leading choice for those in the market for reliable heating solutions. Whether for residential or commercial applications, it effectively meets the diverse heating needs of users, providing comfort and efficiency for years to come.