3.0 INSTALLATION AND SETUP

3.0 INSTALLATION AND SETUP

3.1INSTALLATION (Refer to Figure 5 on the next page)

1.Ensure that all DIP switches are in the OFF position, as shown in Figure 3. The DIP switches are on the underside of the keyboard.

2.The RJ-45 connectors on the supplied Pelco power pack serve a dual func- tion: (1) to provide power to the keyboard and (2), serve as a data path be- tween the keyboard and the CM9760-CC1. Connect a “straight” or “parallel” cable (RJ-45 to RJ-45) between COM 1 on the keyboard and the RJ-45 key- board input connector on the power pack (refer to Figure 5).

3.Connect the other “reverse” or “cross-wired” cable (also RJ-45 to RJ-45) be- tween the remaining RJ-45 connector on the power pack and an appropriate RJ-45 Sercom port (most likely Com port 6) of the Sercom board occupying slot 1 on the rear of the Pelco CPU (CM9760-CC1).

4.Plug the power pack into a 120 VAC power source.

5.Turn the main power supply switch ON.

Figure 3. DIP Switches

 

VOLUME

 

RELAY 12C COM 3 COM 2 COM 1

RESET

DIP SWITCHES

 

BUTTON

(REFER TO APPENDIX C FOR ALL KEYBOARD CONNECTOR PIN-OUTS)

Figure 4. Com Ports and DIP Switches

3.2 SETUP

NOTE: The DIP switches are on the underside of the keyboard (see Fig- ure 4). The default setup PIN is 1234. It may be altered in setup mode. See Appendix E, Setup Mode Menu Tree.

NOTE: To restore factory default settings, set DIP switch positions 1, 2 and 8 to the ON position and re- cycle power.

The CM9760-KBD is configured using setup mode. In setup mode, it is possible to

Nominate a PIN for entering setup mode

Nominate a PIN that provides access to features on the define menu

Calibrate the joystick

Adjust the brightness of the display

Set the data transmission speeds at which the keyboard’s three COM ports operate

Configure the internal relays and assign macros to them

Assign functions to user-definable control keys

Select direct camera control receiver/drivers.

Assign logical camera numbers to directly controlled cameras.

Download/upload the definitions of the user-definable control keys and user defined icons between keyboards

Adjust the time-out period

Select a host processor

3.2.1To Activate Setup Mode

1.Set DIP switch 2 to the ON position

2.Enter your setup PIN.